VA 520 Inline Flow Meters

Check up to five results to perform an action.

Display shows 2 values at the same time:
  • Present flow in m³/h, CFM
  • Total consumption (counter reading) in CF
  • Temperature measurement
Readout values in the display can be rotated by 180º, e.g. for overhead installation.




   
  Results 1 - 16 of 16 1 

Item #

Item Name

Parameters

Units Adjustable Via Keys at Display

Sensor

Measured Medium

Gas Types are Adjustable Over CS Service Software or CS Data Logger

Accuracy

Accuracy on Request

Operating Temperature

Operating Temperature with Pressure Sensor

Operating Pressure

Optional Pressure

Digital Output

Analog Output for Cubic Feet per Minute (CFM)

Pulse Output

Direct Current Voltage (VDC) Supply

Power Supply

Burden

Housing Material

Protection Rating

Measuring Section

Mounting Position

Low-Speed Air Flow (164 Feet (ft)/Sec (s))

Standard Air Flow (304 Feet (ft)/Sec (s))

Maximum Air Flow (607 Feet (ft)/Sec (s))

High-Speed Air Flow (735 Feet (ft)/Sec (s))

Note for Air Flow

Low-Speed Argon (Ar) Flow (164 Feet (ft)/Sec (s))

Standard Argon (Ar) Flow (304 Feet (ft)/Sec (s))

Maximum Argon (Ar) Flow (607 Feet (ft)/Sec (s))

High-Speed Argon (Ar) Flow (735 Feet (ft)/Sec (s))

Note for Argon (Ar) Flow

Low-Speed Carbon Dioxide (CO2) Flow (164 Feet (ft)/Sec (s))

Standard Carbon Dioxide (CO2) Flow (304 Feet (ft)/Sec (s))

Maximum Carbon Dioxide (CO2) Flow (607 Feet (ft)/Sec (s))

High-Speed Carbon Dioxide (CO2) Flow (735 Feet (ft)/Sec (s))

Note for Carbon Dioxide (CO2) Flow

Low-Speed Nitrogen (N2) Flow (164 Feet (ft)/Sec (s))

Standard Nitrogen (N2) Flow (304 Feet (ft)/Sec (s))

Maximum Nitrogen (N2) Flow (607 Feet (ft)/Sec (s))

High-Speed Nitrogen (N2) Flow (735 Feet (ft)/Sec (s))

Note for Nitrogen (N2) Flow

Low-Speed Oxygen (O2) Flow (164 Feet (ft)/Sec (s))

Standard Oxygen (O2) Flow (304 Feet (ft)/Sec (s))

Maximum Oxygen (O2) Flow (607 Feet (ft)/Sec (s))

High-Speed Oxygen (O2) Flow (735 Feet (ft)/Sec (s))

Note for Oxygen (O2) Flow

Low-Speed Nitrous Oxide (N2O) Flow (164 Feet (ft)/Sec (s))

Standard Nitrous Oxide (N2O) Flow (304 Feet (ft)/Sec (s))

Maximum Nitrous Oxide (N2O) Flow (607 Feet (ft)/Sec (s))

High-Speed Nitrous Oxide (N2O) Flow (735 Feet (ft)/Sec (s))

Note for Nitrous Oxide (N2O) Flow

Low-Speed Natural Gas (NG) Flow (164 Feet (ft)/Sec (s))

Standard Natural Gas (NG) Flow (304 Feet (ft)/Sec (s))

Maximum Natural Gas (NG) Flow (607 Feet (ft)/Sec (s))

High-Speed Natural Gas (NG) Flow (735 Feet (ft)/Sec (s))

Note for Natural Gas (NG) Flow

Flange Outer Pipe Diameter

Flange Inner Pipe Diameter

Dimension L (Flange)

Note for Dimension L (Flange)

Dimension L1 (Flange)

Dimension H (Flange)

Dimension H1 (Flange)

Diameter D (Flange)

Diameter K (Flange)

n x Diameter L (Flange)

Connection Thread

Thread Outer Pipe Diameter

Thread Inner Pipe Diameter

Dimension L (Thread)

Note for Dimension L (Thread)

Dimension L1 (Thread)

Dimension H (Thread)

Dimension H1 (Thread)

Dimension A (Thread)

Connection to different Bus systems Options

With a Key Stroke

Options

Application-Technological Features

Additional Information

0695 1520 VA 520 Flow Meter with R 1/4 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404 Any 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
105 m³/h
3.6
cfm
130 m³/h
4.5
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 45 L/min
1.5
cfm
85 m³/h
3
cfm
170 m³/h
6
cfm
205 m³/h
7.2
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
105 m³/h
3.6
cfm
130 m³/h
4.5
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.5
cfm
100 m³/h
3.3
cfm
120 m³/h
4.2
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
100 m³/h
3.6
cfm
125 m³/h
4.2
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
105 m³/h
3.6
cfm
125 m³/h
4.5
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 15 L/min
0.6
cfm
30 m³/h
0.9
cfm
60 m³/h
2.1
cfm
75 m³/h
2.7
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A R 1/4 in. 13.7 mm
0.54
in
8.9 mm
0.35
in
7.6 Inch
194
mm
N/A 5.3 in
137
mm
6.8 in
174.7
mm
6.5 in
165.7
mm
0.5 in
15
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 1527 VA 520 Flow Meter with R 3/8 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404 Any 225 nL/min
8
cfm
25 m³/h
14.7
cfm
50 m³/h
29.4
cfm
60 m³/h
35.3
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 330 nL/min
11.7
cfm
35 m³/h
20.5
cfm
75 m³/h
44.1
cfm
95 m³/h
55.9
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 225 nL/min
7.9
cfm
25 m³/h
14.7
cfm
50 m³/h
29.4
cfm
60 m³/h
35.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 205 nL/min
7.2
cfm
20 m³/h
11.7
cfm
45 m³/h
26.4
cfm
55 m³/h
32.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 215 nL/min
7.5
cfm
20 m³/h
11.7
cfm
45 m³/h
26.4
cfm
55 m³/h
32.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 220 nL/min
7.7
cfm
20 m³/h
11.7
cfm
45 m³/h
26.4
cfm
60 m³/h
35.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 130 nL/min
4.5
cfm
14 m³/h
8.8
cfm
25 m³/h
14.7
cfm
35 m³/h
20.5
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A R 3/8 in. 17.2 mm
0.68
in
12.5 mm
0.49
in
11.8 Inch
300
mm
N/A 7.9 in
200
mm
6.9 in
175
mm
6.5 in
165.7
mm
0.5 in
15
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 1521 VA 520 Flow Meter with R 1/2 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404
1/2
in
Any 20 L/min
14
cfm
45 m³/h
25
cfm
90 m³/h
50
cfm
110 m³/h
60
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 35 L/min
20
cfm
70 m³/h
40
cfm
140 m³/h
80
cfm
170 m³/h
100
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
14
cfm
45 m³/h
25
cfm
90 m³/h
50
cfm
105 m³/h
60
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
13
cfm
40 m³/h
25
cfm
80 m³/h
45
cfm
100 m³/h
55
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
13
cfm
40 m³/h
25
cfm
85 m³/h
50
cfm
105 m³/h
60
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
14
cfm
40 m³/h
25
cfm
85 m³/h
50
cfm
105 m³/h
60
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 14.4 L/min
8
cfm
25 m³/h
15
cfm
50 m³/h
30
cfm
65 m³/h
35
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 21.3 mm
0.84
in
16.1 mm
0.63
in
11.8 in N/A 8.27 in 8.3 in 6.5 in 95 mm 65 mm 4 x 14 R 1/2 in. 21.3 mm
0.84
in
16.1 mm
0.63
in
11.8 Inch
300
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 8.2 in
210
mm
6.9 in
176.4
mm
6.5 in
165.7
mm
0.7 in
20
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 1522 VA 520 Flow Meter with R 3/4 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404
3/4
in
Any 45 L/min
25
cfm
85 m³/h
50
cfm
175 m³/h
100
cfm
215 m³/h
125
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 75 L/min
40
cfm
135 m³/h
80
cfm
275 m³/h
160
cfm
335 m³/h
195
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
85 m³/h
50
cfm
175 m³/h
100
cfm
210 m³/h
125
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 70 L/min
40
cfm
80 m³/h
45
cfm
160 m³/h
95
cfm
195 m³/h
115
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
80 m³/h
45
cfm
165 m³/h
95
cfm
205 m³/h
120
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
85 m³/h
50
cfm
170 m³/h
100
cfm
210 m³/h
120
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
15
cfm
50 m³/h
30
cfm
105 m³/h
60
cfm
125 m³/h
70
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 26.9 mm
1.06
in
21.7 mm
0.85
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 8.5 in 6.5 in 105 mm 75 mm 4 x 14 R 3/4 in. 26.9 mm
1.06
in
21.7 mm
0.85
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.0 in
179.2
mm
6.5 in
165.7
mm
0.7 in
20
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 1523 VA 520 Flow Meter with R 1 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404
1
in
Any 75 L/min
45
cfm
145 m³/h
85
cfm
290 m³/h
170
cfm
355 m³/h
210
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 120 L/min
70
cfm
230 m³/h
135
cfm
460 m³/h
270
cfm
555 m³/h
325
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 75 L/min
45
cfm
145 m³/h
85
cfm
290 m³/h
170
cfm
350 m³/h
205
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 130 L/min
75
cfm
135 m³/h
75
cfm
270 m³/h
155
cfm
325 m³/h
190
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 75 L/min
40
cfm
140 m³/h
80
cfm
280 m³/h
165
cfm
340 m³/h
200
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 75 L/min
45
cfm
140 m³/h
85
cfm
285 m³/h
170
cfm
345 m³/h
205
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
85 m³/h
50
cfm
170 m³/h
100
cfm
210 m³/h
120
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 33.7 mm
1.34
in
27.3 mm
1.07
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 8.7 in 6.5 in 115 mm 85 mm 4 x 14 R 1 in. 33.7 mm
1.34
in
27.3 mm
1.07
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.1 in
182.6
mm
6.5 in
165.7
mm
0.9 in
25
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 1526 VA 520 Flow Meter with R 1-1/4 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404
1-1/4
in
Any 140 L/min
80
cfm
265 m³/h
155
cfm
530 m³/h
310
cfm
640 m³/h
375
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 220 L/min
130
cfm
415 m³/h
245
cfm
830 m³/h
485
cfm
1005 m³/h
590
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 140 L/min
80
cfm
260 m³/h
155
cfm
525 m³/h
305
cfm
635 m³/h
370
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 180 L/min
105
cfm
240 m³/h
140
cfm
485 m³/h
285
cfm
590 m³/h
345
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 135 L/min
80
cfm
250 m³/h
145
cfm
505 m³/h
295
cfm
610 m³/h
360
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 140 L/min
80
cfm
260 m³/h
150
cfm
520 m³/h
305
cfm
630 m³/h
370
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 85 L/min
50
cfm
155 m³/h
90
cfm
310 m³/h
185
cfm
380 m³/h
220
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 42.4 mm
1.67
in
36 mm
1.41
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 9.2 in 6.5 in 140 mm 100 mm 4 x 18 R 1-1/4 in. 42.4 mm
1.67
in
36.0 mm
1.41
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.3 in
186.9
mm
6.5 in
165.7
mm
0.9 in
25
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 1524 VA 520 Flow Meter with R 1-1/2 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404
1-1/2
in
Any 195 L/min
115
cfm
365 m³/h
215
cfm
730 m³/h
430
cfm
885 m³/h
520
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 305 L/min
180
cfm
570 m³/h
335
cfm
1140 m³/h
670
cfm
1385 m³/h
815
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 195 L/min
115
cfm
360 m³/h
210
cfm
720 m³/h
425
cfm
875 m³/h
515
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 295 L/min
175
cfm
335 m³/h
195
cfm
670 m³/h
395
cfm
815 m³/h
475
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 185 L/min
110
cfm
345 m³/h
205
cfm
695 m³/h
410
cfm
845 m³/h
495
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 190 L/min
110
cfm
355 m³/h
210
cfm
715 m³/h
420
cfm
865 m³/h
510
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 115 L/min
65
cfm
215 m³/h
125
cfm
430 m³/h
250
cfm
520 m³/h
305
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 48.3 mm
1.9
in
41.9 mm
1.65
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 9.4 in 6.5 in 150 mm 110 mm 4 x 18 R 1-1/2 in. 48.3 mm
1.90
in
41.9 mm
1.65
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.3 in
186.9
mm
6.5 in
165.7
mm
0.9 in
25
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 1525 VA 520 Flow Meter with R 2 Inch (in) Connection Thread and Stainless Steel 1.4404 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4404
2
in
Any 320 L/min
190
cfm
600 m³/h
350
cfm
1195 m³/h
700
cfm
1450 m³/h
850
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 505 L/min
295
cfm
935 m³/h
550
cfm
1870 m³/h
1100
cfm
2265 m³/h
1330
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 320 L/min
185
cfm
590 m³/h
345
cfm
1185 m³/h
695
cfm
1430 m³/h
840
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 505 L/min
300
cfm
550 m³/h
320
cfm
1100 m³/h
645
cfm
1330 m³/h
780
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 305 L/min
180
cfm
570 m³/h
335
cfm
1140 m³/h
670
cfm
1380 m³/h
810
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 315 L/min
185
cfm
585 m³/h
345
cfm
1170 m³/h
690
cfm
1420 m³/h
835
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 190 L/min
110
cfm
355 m³/h
205
cfm
705 m³/h
415
cfm
855 m³/h
500
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 60.3 mm
2.37
in
53.1 mm
2.09
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 9.7 in 6.5 in 165 mm 125 mm 4 x 18 R 2 in. 60.3 mm
2.37
in
53.1 mm
2.09
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.7 in
195.9
mm
6.5 in
165.7
mm
1.1 in
30
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0520 VA 520 Flow Meter with R 1/4 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301 Any 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
105 m³/h
3.6
cfm
130 m³/h
4.5
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 45 L/min
1.5
cfm
85 m³/h
3
cfm
170 m³/h
6
cfm
205 m³/h
7.2
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
105 m³/h
3.6
cfm
130 m³/h
4.5
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.5
cfm
100 m³/h
3.3
cfm
120 m³/h
4.2
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
100 m³/h
3.6
cfm
125 m³/h
4.2
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
0.9
cfm
50 m³/h
1.8
cfm
105 m³/h
3.6
cfm
125 m³/h
4.5
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 15 L/min
0.6
cfm
30 m³/h
0.9
cfm
60 m³/h
2.1
cfm
75 m³/h
2.7
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A R 1/4 in. 13.7 mm
0.54
in
8.9 mm
0.35
in
7.6 Inch
194
mm
N/A 5.3 in
137
mm
6.8 in
174.7
mm
6.5 in
165.7
mm
0.5 in
15
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0527 VA 520 Flow Meter with R 3/8 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301 Any 225 nL/min
8
cfm
25 m³/h
14.7
cfm
50 m³/h
29.4
cfm
60 m³/h
35.3
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 330 nL/min
11.7
cfm
35 m³/h
20.5
cfm
75 m³/h
44.1
cfm
95 m³/h
55.9
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 225 nL/min
7.9
cfm
25 m³/h
14.7
cfm
50 m³/h
29.4
cfm
60 m³/h
35.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 205 nL/min
7.2
cfm
20 m³/h
11.7
cfm
45 m³/h
26.4
cfm
55 m³/h
32.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 215 nL/min
7.5
cfm
20 m³/h
11.7
cfm
45 m³/h
26.4
cfm
55 m³/h
32.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 220 nL/min
7.7
cfm
20 m³/h
11.7
cfm
45 m³/h
26.4
cfm
60 m³/h
35.3
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 130 nL/min
4.5
cfm
14 m³/h
8.8
cfm
25 m³/h
14.7
cfm
35 m³/h
20.5
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A R 3/8 in. 17.2 mm
0.68
in
12.5 mm
0.49
in
11.8 Inch
300
mm
N/A 7.9 in
200
mm
6.9 in
175
mm
6.5 in
165.7
mm
0.5 in
15
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0521 VA 520 Flow Meter with R 1/2 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301
1/2
in
Any 20 L/min
14
cfm
45 m³/h
25
cfm
90 m³/h
50
cfm
110 m³/h
60
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 35 L/min
20
cfm
70 m³/h
40
cfm
140 m³/h
80
cfm
170 m³/h
100
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
14
cfm
45 m³/h
25
cfm
90 m³/h
50
cfm
105 m³/h
60
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
13
cfm
40 m³/h
25
cfm
80 m³/h
45
cfm
100 m³/h
55
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
13
cfm
40 m³/h
25
cfm
85 m³/h
50
cfm
105 m³/h
60
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 20 L/min
14
cfm
40 m³/h
25
cfm
85 m³/h
50
cfm
105 m³/h
60
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 14.4 L/min
8
cfm
25 m³/h
15
cfm
50 m³/h
30
cfm
65 m³/h
35
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 21.3 mm
0.84
in
16.1 mm
0.63
in
11.8 in N/A 8.27 in 8.3 in 6.5 in 95 mm 65 mm 4 x 14 R 1/2 in. 21.3 mm
0.84
in
16.1 mm
0.63
in
11.8 Inch
300
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 8.2 in
210
mm
6.9 in
176.4
mm
6.5 in
165.7
mm
0.7 in
20
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0522 VA 520 Flow Meter with R 3/4 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301
3/4
in
Any 45 L/min
25
cfm
85 m³/h
50
cfm
175 m³/h
100
cfm
215 m³/h
125
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 75 L/min
40
cfm
135 m³/h
80
cfm
275 m³/h
160
cfm
335 m³/h
195
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
85 m³/h
50
cfm
175 m³/h
100
cfm
210 m³/h
125
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 70 L/min
40
cfm
80 m³/h
45
cfm
160 m³/h
95
cfm
195 m³/h
115
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
80 m³/h
45
cfm
165 m³/h
95
cfm
205 m³/h
120
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
85 m³/h
50
cfm
170 m³/h
100
cfm
210 m³/h
120
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 25 L/min
15
cfm
50 m³/h
30
cfm
105 m³/h
60
cfm
125 m³/h
70
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 26.9 mm
1.06
in
21.7 mm
0.85
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 8.5 in 6.5 in 105 mm 75 mm 4 x 14 R 3/4 in. 26.9 mm
1.06
in
21.7 mm
0.85
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.0 in
179.2
mm
6.5 in
165.7
mm
0.7 in
20
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0523 VA 520 Flow Meter with R 1 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301
1
in
Any 75 L/min
45
cfm
145 m³/h
85
cfm
290 m³/h
170
cfm
355 m³/h
210
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 120 L/min
70
cfm
230 m³/h
135
cfm
460 m³/h
270
cfm
555 m³/h
325
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 75 L/min
45
cfm
145 m³/h
85
cfm
290 m³/h
170
cfm
350 m³/h
205
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 130 L/min
75
cfm
135 m³/h
75
cfm
270 m³/h
155
cfm
325 m³/h
190
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 75 L/min
40
cfm
140 m³/h
80
cfm
280 m³/h
165
cfm
340 m³/h
200
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 75 L/min
45
cfm
140 m³/h
85
cfm
285 m³/h
170
cfm
345 m³/h
205
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 45 L/min
25
cfm
85 m³/h
50
cfm
170 m³/h
100
cfm
210 m³/h
120
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 33.7 mm
1.34
in
27.3 mm
1.07
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 8.7 in 6.5 in 115 mm 85 mm 4 x 14 R 1 in. 33.7 mm
1.34
in
27.3 mm
1.07
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.1 in
182.6
mm
6.5 in
165.7
mm
0.9 in
25
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0526 VA 520 Flow Meter with R 1-1/4 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301
1-1/4
in
Any 140 L/min
80
cfm
265 m³/h
155
cfm
530 m³/h
310
cfm
640 m³/h
375
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 220 L/min
130
cfm
415 m³/h
245
cfm
830 m³/h
485
cfm
1005 m³/h
590
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 140 L/min
80
cfm
260 m³/h
155
cfm
525 m³/h
305
cfm
635 m³/h
370
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 180 L/min
105
cfm
240 m³/h
140
cfm
485 m³/h
285
cfm
590 m³/h
345
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 135 L/min
80
cfm
250 m³/h
145
cfm
505 m³/h
295
cfm
610 m³/h
360
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 140 L/min
80
cfm
260 m³/h
150
cfm
520 m³/h
305
cfm
630 m³/h
370
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 85 L/min
50
cfm
155 m³/h
90
cfm
310 m³/h
185
cfm
380 m³/h
220
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 42.4 mm
1.67
in
36 mm
1.41
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 9.2 in 6.5 in 140 mm 100 mm 4 x 18 R 1-1/4 in. 42.4 mm
1.67
in
36.0 mm
1.41
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.3 in
186.9
mm
6.5 in
165.7
mm
0.9 in
25
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0524 VA 520 Flow Meter with R 1-1/2 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301
1-1/2
in
Any 195 L/min
115
cfm
365 m³/h
215
cfm
730 m³/h
430
cfm
885 m³/h
520
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 305 L/min
180
cfm
570 m³/h
335
cfm
1140 m³/h
670
cfm
1385 m³/h
815
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 195 L/min
115
cfm
360 m³/h
210
cfm
720 m³/h
425
cfm
875 m³/h
515
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 295 L/min
175
cfm
335 m³/h
195
cfm
670 m³/h
395
cfm
815 m³/h
475
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 185 L/min
110
cfm
345 m³/h
205
cfm
695 m³/h
410
cfm
845 m³/h
495
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 190 L/min
110
cfm
355 m³/h
210
cfm
715 m³/h
420
cfm
865 m³/h
510
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 115 L/min
65
cfm
215 m³/h
125
cfm
430 m³/h
250
cfm
520 m³/h
305
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 48.3 mm
1.9
in
41.9 mm
1.65
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 9.4 in 6.5 in 150 mm 110 mm 4 x 18 R 1-1/2 in. 48.3 mm
1.90
in
41.9 mm
1.65
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.3 in
186.9
mm
6.5 in
165.7
mm
0.9 in
25
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.
0695 0525 VA 520 Flow Meter with R 2 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases CFM
ft/min

g/s

kg/h

kg/min

L/s

lb/h

lb/min

m/s

m³/h

m³/min
Thermal Mass Flow Sensor Air
Gases
Air
Argon

CO2

Nitrogen

Oxygen
± 1.5% of Measured Value (M.V.)
± 0.3% of Full Scale (F.S.)
± 0.3% of Full Scale (F.S.)
± 1% of Measured Value (M.V.)
-22 to 176 ºF -25 to 349 ºF -1 to 232 psi Up to Nominal Pressure (PN) 40 (Modbus-RTU), Optional: Ethernet interface PoE)
M-Bus

RS 485 Interface
4 to 20 mA 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay
18 to 36 V 5 W < 500 Ω Polycarbonate Ingress Protection (IP 65) Stainless Steel 1.4301
2
in
Any 320 L/min
190
cfm
600 m³/h
350
cfm
1195 m³/h
700
cfm
1450 m³/h
850
cfm
Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi 505 L/min
295
cfm
935 m³/h
550
cfm
1870 m³/h
1100
cfm
2265 m³/h
1330
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 320 L/min
185
cfm
590 m³/h
345
cfm
1185 m³/h
695
cfm
1430 m³/h
840
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 505 L/min
300
cfm
550 m³/h
320
cfm
1100 m³/h
645
cfm
1330 m³/h
780
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 305 L/min
180
cfm
570 m³/h
335
cfm
1140 m³/h
670
cfm
1380 m³/h
810
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 315 L/min
185
cfm
585 m³/h
345
cfm
1170 m³/h
690
cfm
1420 m³/h
835
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 190 L/min
110
cfm
355 m³/h
205
cfm
705 m³/h
415
cfm
855 m³/h
500
cfm
Setting to DIN 1343: 32 ºF, 14.7 psi 60.3 mm
2.37
in
53.1 mm
2.09
in
18.7 in Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. 10.83 in 9.7 in 6.5 in 165 mm 125 mm 4 x 18 R 2 in. 60.3 mm
2.37
in
53.1 mm
2.09
in
18.7 Inch
475
mm
Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! 10.8 in
275
mm
7.7 in
195.9
mm
6.5 in
165.7
mm
1.1 in
30
mm
There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.