| Shipping | Tax | Terms Shopping Cart 0 Items Request for Quote 0 Items All Categories > VA 520 Inline Flow Meters > Item # 0695 0525 Download PDF Download PDF Printable Page Email This Page Save To Favorites Please wait… Item # 0695 0525, VA 520 Flow Meter with R 2 Inch (in) Connection Thread and Stainless Steel 1.4301 Measuring Section Web Price QUOTE larger image Display shows 2 values at the same time:Present flow in m³/h, CFMTotal consumption (counter reading) in CFTemperature measurementReadout values in the display can be rotated by 180º, e.g. for overhead installation. Specifications Parameters m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases Units Adjustable Via Keys at Display CFM ft/min g/s kg/h kg/min L/s lb/h lb/min m/s m³/h m³/min Sensor Thermal Mass Flow Sensor Measured Medium Air Gases Gas Types are Adjustable Over CS Service Software or CS Data Logger Air Argon CO2 Nitrogen Oxygen Accuracy ± 1.5% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) Accuracy on Request ± 0.3% of Full Scale (F.S.) ± 1% of Measured Value (M.V.) Operating Temperature -22 to 176 ºF Operating Temperature with Pressure Sensor -25 to 349 ºF Operating Pressure -1 to 232 psi Optional Pressure Up to Nominal Pressure (PN) 40 Digital Output (Modbus-RTU), Optional: Ethernet interface PoE) M-Bus RS 485 Interface Analog Output for Cubic Feet per Minute (CFM) 4 to 20 mA Pulse Output 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.Alternatively, the pulse output can be used as an alarm relay Direct Current Voltage (VDC) Supply 18 to 36 V Power Supply 5 W Burden < 500 Ω Housing Material Polycarbonate Protection Rating Ingress Protection (IP 65) Measuring Section Stainless Steel 1.4301 2 in Mounting Position Any Low-Speed Air Flow (164 Feet (ft)/Sec (s)) 320 L/min190 cfm Standard Air Flow (304 Feet (ft)/Sec (s)) 600 m³/h350 cfm Maximum Air Flow (607 Feet (ft)/Sec (s)) 1195 m³/h700 cfm High-Speed Air Flow (735 Feet (ft)/Sec (s)) 1450 m³/h850 cfm Note for Air Flow Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi Low-Speed Argon (Ar) Flow (164 Feet (ft)/Sec (s)) 505 L/min295 cfm Standard Argon (Ar) Flow (304 Feet (ft)/Sec (s)) 935 m³/h550 cfm Maximum Argon (Ar) Flow (607 Feet (ft)/Sec (s)) 1870 m³/h1100 cfm High-Speed Argon (Ar) Flow (735 Feet (ft)/Sec (s)) 2265 m³/h1330 cfm Note for Argon (Ar) Flow Setting to DIN 1343: 32 ºF, 14.7 psi Low-Speed Carbon Dioxide (CO2) Flow (164 Feet (ft)/Sec (s)) 320 L/min185 cfm Standard Carbon Dioxide (CO2) Flow (304 Feet (ft)/Sec (s)) 590 m³/h345 cfm Maximum Carbon Dioxide (CO2) Flow (607 Feet (ft)/Sec (s)) 1185 m³/h695 cfm High-Speed Carbon Dioxide (CO2) Flow (735 Feet (ft)/Sec (s)) 1430 m³/h840 cfm Note for Carbon Dioxide (CO2) Flow Setting to DIN 1343: 32 ºF, 14.7 psi Low-Speed Nitrogen (N2) Flow (164 Feet (ft)/Sec (s)) 505 L/min300 cfm Standard Nitrogen (N2) Flow (304 Feet (ft)/Sec (s)) 550 m³/h320 cfm Maximum Nitrogen (N2) Flow (607 Feet (ft)/Sec (s)) 1100 m³/h645 cfm High-Speed Nitrogen (N2) Flow (735 Feet (ft)/Sec (s)) 1330 m³/h780 cfm Note for Nitrogen (N2) Flow Setting to DIN 1343: 32 ºF, 14.7 psi Low-Speed Oxygen (O2) Flow (164 Feet (ft)/Sec (s)) 305 L/min180 cfm Standard Oxygen (O2) Flow (304 Feet (ft)/Sec (s)) 570 m³/h335 cfm Maximum Oxygen (O2) Flow (607 Feet (ft)/Sec (s)) 1140 m³/h670 cfm High-Speed Oxygen (O2) Flow (735 Feet (ft)/Sec (s)) 1380 m³/h810 cfm Note for Oxygen (O2) Flow Setting to DIN 1343: 32 ºF, 14.7 psi Low-Speed Nitrous Oxide (N2O) Flow (164 Feet (ft)/Sec (s)) 315 L/min185 cfm Standard Nitrous Oxide (N2O) Flow (304 Feet (ft)/Sec (s)) 585 m³/h345 cfm Maximum Nitrous Oxide (N2O) Flow (607 Feet (ft)/Sec (s)) 1170 m³/h690 cfm High-Speed Nitrous Oxide (N2O) Flow (735 Feet (ft)/Sec (s)) 1420 m³/h835 cfm Note for Nitrous Oxide (N2O) Flow Setting to DIN 1343: 32 ºF, 14.7 psi Low-Speed Natural Gas (NG) Flow (164 Feet (ft)/Sec (s)) 190 L/min110 cfm Standard Natural Gas (NG) Flow (304 Feet (ft)/Sec (s)) 355 m³/h205 cfm Maximum Natural Gas (NG) Flow (607 Feet (ft)/Sec (s)) 705 m³/h415 cfm High-Speed Natural Gas (NG) Flow (735 Feet (ft)/Sec (s)) 855 m³/h500 cfm Note for Natural Gas (NG) Flow Setting to DIN 1343: 32 ºF, 14.7 psi Flange Outer Pipe Diameter 60.3 mm2.37 in Flange Inner Pipe Diameter 53.1 mm2.09 in Dimension L (Flange) 18.7 in Note for Dimension L (Flange) Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. Dimension L1 (Flange) 10.83 in Dimension H (Flange) 9.7 in Dimension H1 (Flange) 6.5 in Diameter D (Flange) 165 mm Diameter K (Flange) 125 mm n x Diameter L (Flange) 4 x 18 Connection Thread R 2 in. Thread Outer Pipe Diameter 60.3 mm2.37 in Thread Inner Pipe Diameter 53.1 mm2.09 in Dimension L (Thread) 18.7 Inch475 mm Note for Dimension L (Thread) Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! Dimension L1 (Thread) 10.8 in275 mm Dimension H (Thread) 7.7 in195.9 mm Dimension H1 (Thread) 6.5 in165.7 mm Dimension A (Thread) 1.1 in30 mm Connection to different Bus systems Options There are different options available for connection to modern Bus systems:Ethernet interface (Modbus-TCP) / PoEM-BUSModbus-RTU With a Key Stroke Reset counter readingSelect unitsZero-point adjustment, leak flow volume suppression Options Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.A meter reading is available for each flow direction. Application-Technological Features Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy managementSystems, building management systems, PLCEasy and affordable installationUnits freely selectable via keys on the display CF, lbs, CFMCompressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypadAnalog output 4 to 20 mA, pulse output (electrically isolated)High measuring accuracy even in the lower measuring range (ideal for leakage measurement)Negligibly small loss of pressureCalorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved partsComprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./minvalues ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus Additional Information Modbus-RTU output4 to 20 mA output for present flowPulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)NEW: Integrated pressure sensor (optional)Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessaryEasy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)High measuring accuracy due to defined measuring section (inlet and outlet section)Display head rotatable by 180º e.g. in case of reverse flow directionThe sensor can be removed and cleaned. MORE IMAGES · VA 520 Inline Flow Meters - 2 · VA 520 Inline Flow Meters - 3 DOWNLOADS Datasheet for VA 520 Inline Flow Meters (PDF, 971KB) Maintain Your Air Compressor Learn more about maintaining your air compressor by downloading our eBook on air compressor maintenance. Download eBook