Brands |
N/A Kaeser Compressors |
Model |
N/A KBD 4300 |
Working Pressure |
N/A 100 psig |
Inlet Flow at 100 Pounds Per Square Inch Gauge (psig) Pressure and 100 ºF Temperature |
N/A 4300 scfm |
Blower Flow Rate |
N/A 732 scfm |
Normal Blower Flow Power |
N/A 7.5 hp |
Average Blower Power |
N/A 4.2 kW |
Normal Heater Power |
N/A 70 kW |
Average Heater Power |
N/A 50.1 kW |
Approximate Weight |
N/A 12350 lb |
Inlet/Outlet Connections Type |
N/A Flange |
Inlet/Outlet Connection Size |
N/A 6 in |
Pre-Filter (KB Series) |
N/A 5000 scfm |
High-Temp After-Filter (HTA Series) |
N/A 4800 scfm |
Total Replacement Desiccant |
N/A 5650 lb |
Standard |
N/A National Electrical Manufacturers Association (NEMA) 4 |
Features and Advantages |
N/A
|
N/A
Solid state logic accurately controls inlet and purge valves which direct wet compressed air to the regenerated tower, and heated ambient air to the tower in need of regeneration. The process of adsorption and desorption can be repeated several thousand times before the desiccant must be replaced. |
Note |
N/A
Average Heater kW (fixed cycle) = [kW required to produce 280 ºF temperature rise] x [235 min. max heat time] / [240 min drying time]. Average Blower kW (fixed cycle) = [Blower kW] x [235 min. max heat time] / [240 min dryer time]. Average Dryer kW (fixed cycle) = [Average Heater kW] + [Average Blower kW] Actual kW is less and proportional to the average water load presented to the dryer. |