Print Back

Electronic Fuel Primer and Air Bleed (EFPA) for easy priming and minimal downtime

Delta Demand Excitation delivers the industry’s best motor starting capability and automatically adjusts under variable loads

Curbside electrical panel for increased safety

Rugged, high quality trailer

24-hour run time on all units

Large mechanical lugs allow for easy connection in hard wire applications (except SDG25)

110%fluid containment and external drain for increased safety

Extended runtime through external fuel connection

Excellent warranty

1 year 1500 hour bumper to bumper warranty

2 year 2000 hour alternator warranty

2 year 2000 hour full engine warranty

Airman® 25 Kilo Volt Ampere (kVA) Prime Power Electrical Power Generator
Unit of Measure
Items Image
SDG13LAX
Airman® 12.5 kVA Prime Power Generator
Airman® 25 Kilo Volt Ampere (kVA) Prime Power Electrical Power Generator
SDG25S-8E1
Airman® 25 kVA Prime Generator
Image
SDG40S-8E1
Airman® 38 kVA Prime Power Generator
Airman® 45 Kilo Volt Ampere (kVA) Prime Power Electrical Power Generator
SDG45S-8E1
Airman® 45 kVA Prime Power Generator
Airman® 65 Kilo Volt Ampere (kVA) Prime Power Electrical Power Generator
SDG65S-8E1
Airman® 65 kVA Prime Power Generator
Brands N/A Airman®
Generator Type N/A Airman® Generator End N/A Airman® Generator End N/A Airman Generator End N/A Airman® Generator End N/A Airman® Generator End
Armature Connection N/A Star with Neutral Zig Zag
Number of Poles N/A 4
Insulation N/A F-Class
Excitation N/A Brushless with Automatic Voltage Regulator (AVR)
Voltage Regulation (±) N/A 0.5 %
Power Factor N/A 0.8 N/A 0.8 N/A 1.0 N/A 0.8 N/A 0.8
Frequency N/A 50 Hz60 Hz
Prime Power N/A 12.5 kVA9.6 kW N/A 25 kVA20 kW N/A 36 kVA28.8 kW N/A 45 kVA36 kW N/A 65 kVA52 kW
Standby Power N/A 13.8 kVA11 kW N/A 27.5 kVA22 kW N/A 37.8 kVA30.2 kW N/A 48.5 kVA38.8 kW N/A 67 kVA53.6 kW
Voltage at Single Phase (Switchable) N/A 120 V240 V N/A 120 V240 V277 V N/A 120 V240 V277 V N/A 120 V240 V277 V N/A 120 V240 V277 V
Voltage at Three Phase (Switchable) N/A 208 V240 V N/A 208 V240 V416 V480 V N/A 208 V240 V416 V480 V N/A 208 V240 V416 V480 V N/A 208 V240 V416 V480 V
Current at Single Phase 120 Volt (V) N/A 40 A x 2 N/A 60 A x 2 N/A 108 A x 2 N/A 108 A x 2 N/A 152 A x 2
Current at Single Phase 240 Volt (V) N/A 40 A N/A 60 A N/A 108 A N/A 108 A N/A 152 A
Current at Three Phase 208 Volt (V) N/A 30 A N/A 60 A N/A 95 A N/A 119 A N/A 167 A
Current at Three Phase 240 Volt (V) N/A 30 A N/A 60 A N/A 86 A N/A 108 A N/A 152 A
Current at Three Phase 480 Volt (V) N/A N/A 30 A N/A 43 A N/A 54 A N/A 76 A
Engine Model N/A Kubota D1503 N/A Isuzu 4LE2T N/A Kubota V2403-CR-T N/A lsuzu 4LE2X N/A Isuzu 4JJ1X
Environmental Protection Agency (EPA) Emission Level N/A Tier 4 Final
Engine Type N/A 4-Cycle, Water-Cooled, Direct Injection, Turbo Charged N/A 4-Cycle, Water-Cooled, Direct Injection, Turbo Charged N/A 4-Cycle, Water-Cooled, Direct Injection N/A 4-Cycle, Water-Cooled, Direct Injection, Turbo Charged N/A 4-Cycle, Water-Cooled, Direct Injection
Number of Cylinders N/A 4
Output Power at Rated Speed 1800 Revolutions Per Minute (rpm) N/A 18.4 hp N/A 33.3 hp N/A 44.9 hp N/A 59.0 hp N/A 86.5 hp
Governor Type N/A Electronic
Integral Fuel Tank Capacity N/A 26.4 gal N/A 51.5 gal N/A 84.5 gal N/A 106 gal N/A 111 gal
Fuel Containment N/A 110 %
Lubricating Oil Capacity N/A 1.72 gal N/A 2.7 gal N/A 2.6 gal N/A 3.1 gal N/A 1 gal
Coolant Capacity N/A 1.72 gal N/A 2.7 gal N/A 2.5 gal N/A 2.5 gal N/A 3 gal
Battery Type N/A 12V-55ah N/A 12 V x 1 (12 V System) N/A 12 V x 1 (12 V System) N/A 12 V x 1 (12 V System) N/A 12 V x 1 (12 V System)
Fuel Consumption at Full Load N/A 1 gal/h N/A 1.6 gal/h N/A 2.3 gal/h N/A 2.8 gal/h N/A 3.9 gal/h
Fuel Consumption at 75 Percent Load N/A .79 gal/h N/A 1.3 gal/h N/A 1.7 gal/h N/A 2.1 gal/h N/A 3.1 gal/h
Fuel Consumption at 50 Percent Load N/A .58 gal/h N/A 1.0 gal/h N/A 1.2 gal/h N/A 1.5 gal/h N/A 23 gal/h
Run Time at Full Load N/A 26.4 hours N/A 32.1 hours N/A 36.7 hours N/A 37.8 hours N/A 28.5 hours
Length without Trailer N/A 55 in N/A 67 in N/A 75 in N/A 82 in N/A 97 in
Width without Trailer N/A 26 in N/A 31 in N/A 38 in N/A 38 in N/A 39 in
Height without Trailer N/A 46 in N/A 55 in N/A 61 in N/A 61 in N/A 67 in
Length with Trailer N/A 115 in N/A 119 in N/A 144 in N/A 144 in N/A 160 in
Width with Trailer N/A 62 in N/A 54 in N/A 70 in N/A 70 in N/A 74 in
Height with Trailer N/A 60.5 in N/A 62 in N/A 73 in N/A 73 in N/A 84.25 in
Gross Vehicle Weight Rating (GVWR) N/A 1995 lb N/A 2950 lb N/A 4057 lb N/A 5500 lb N/A 4189 lb
Trailer Weight N/A 494 lb N/A 625 lb N/A 992 lb N/A 1225 lb N/A 1074 lb
Dry Weight N/A 1290 lb N/A 2433 lb N/A 2426 lb N/A 3831 lb N/A 3307 lb
Operating Weight N/A 1500 lb N/A 2830 lb N/A 3065 lb N/A 4599 lb N/A 4189 lb
Sound Level at 23 Feet (ft) (No Load) N/A 58 dBA N/A 57 dBA N/A 57 dBA N/A 57 dBA N/A 59 dBA
Sound Level at 23 Feet (ft) (Full Load) N/A 64 dBA N/A 63 dBA N/A 61 dBA N/A 64 dBA N/A 65 dBA
Features N/A

The industry's first choice!

  • Delta Demand Excitation delivers the industry's best motor starting capability and automatically adjusts under variable loads
  • Curbside electrical panel for increased safety
  • Electronic Fuel Primer and Air Bleed (EFPA) for easy priming and minimal downtime
  • 24-hour run time on all units
  • Extended run time through external fuel connection
  • 110% fluid containment and external drain for increased safety
N/A

The industry's first choice!

  • Delta Demand Excitation delivers the industry's best motor starting capability and automatically adjusts under variable loads
  • Curbside electrical panel for increased safety
  • Electronic Fuel Primer and Air Bleed (EFPA) for easy priming and minimal downtime
  • 24-hour run time on all units
  • Extended run time through external fuel connection
  • 110% fluid containment and external drain for increased safety
N/A

The industry's first choice!

  • Delta Demand Excitation delivers the industry's best motor starting capability and automatically adjusts under variable loads
  • Curbside electrical panel for increased safety
  • Electronic Fuel Primer and Air Bleed (EFPA) for easy priming and minimal downtime
  • 24-hour run time on all units
  • Extended run time through external fuel connection
  • Large mechanical lugs allow for easy connection in hard wire applications
  • 110% fluid containment and external drain for increased safety
N/A

The industry's first choice!

  • Delta Demand Excitation delivers the industry's best motor starting capability and automatically adjusts under variable loads
  • Curbside electrical panel for increased safety
  • Electronic Fuel Primer and Air Bleed (EFPA) for easy priming and minimal downtime
  • 24-hour run time on all units
  • Extended run time through external fuel connection
  • Large mechanical lugs allow for easy connection in hard wire applications
  • 110% fluid containment and external drain for increased safety
N/A

The industry's first choice!

  • Delta Demand Excitation delivers the industry's best motor starting capability and automatically adjusts under variable loads
  • Curbside electrical panel for increased safety
  • Electronic Fuel Primer and Air Bleed (EFPA) for easy priming and minimal downtime
  • 24-hour run time on all units
  • Extended run time through external fuel connection
  • Large mechanical lugs allow for easy connection in hard wire applications
  • 110% fluid containment and external drain for increased safety
Excellent Warranty N/A
  • 1 year 1500 hour bumper to bumper warranty
  • 2 year 2000 hour alternator warranty
  • 2 year 2000 hour full engine warranty
Note N/A

All specifications are subject to change without notice.

Alliance North America, Inc. is committed to supplying the highest quality products with unmatched performance that maintain their value over time. Delivery of Airman® products is only the beginning of our commitment to our customers. With dedicated parts and service, from the first handshake to the last oil change, we are here to keep your Airman® making you dollar after dollar.

Airman® is a trademark of HOKUETSU INDUSTRIES CO.. LTD.