Specifications
Shipping Weight |
N/A 1286 lb |
Feed at 90 psig (99.99 Purity) |
N/A 66 scfm |
Output at 70 psig (99.99 Purity) |
N/A 535 scfh |
Feed at 90 psig (99.9 Purity) |
N/A 65 scfm |
Output at 70 psig (99.9 Purity) |
N/A 859 scfh |
Feed at 90 psig (99.5 Purity) |
N/A 61 scfm |
Output at 69 psig (99.5 Purity) |
N/A 1021 scfh |
Feed at 90 psig (99.0 Purity) |
N/A 70 scfm |
Output at 68 psig (99.0 Purity) |
N/A 1277 scfh |
Feed at 90 psig (98.0 Purity) |
N/A 76 scfm |
Output at 65 psig (98.0 Purity) |
N/A 1578 scfh |
Feed at 90 psig (95.0 Purity) |
N/A 85 scfm |
Output at 57 psig (95.0 Purity) |
N/A 2043 scfh |
Feed at 110 psig (99.99 Purity) |
N/A 75 scfm |
Output at 90 psig (99.99 Purity) |
N/A 608 scfh |
Feed at 110 psig (99.9 Purity) |
N/A 72 scfm |
Output at 90 psig (99.9 Purity) |
N/A 976 scfh |
Feed at 110 psig (99.5 Purity) |
N/A 70 scfm |
Output at 88 psig (99.5 Purity) |
N/A 1161 scfh |
Feed at 110 psig (99.0 Purity) |
N/A 80 scfm |
Output at 86 psig (99.0 Purity) |
N/A 1451 scfh |
Feed at 110 psig (98.0 Purity) |
N/A 87 scfm |
Output at 80 psig (98.0 Purity) |
N/A 1794 scfh |
Feed at 110 psig (95.0 Purity) |
N/A 97 scfm |
Output at 75 psig (95.0 Purity) |
N/A 2321 scfh |
Minimum Storage Capacity (Air) |
N/A 80 gal |
Minimum Storage Capacity (N2) |
N/A 80 gal |
Voltage |
N/A 100 V115 V120 V |
Phase |
N/A 1 |
Power Supply Frequency |
N/A 50 Hz60 Hz |
Inlet Ports |
N/A 1 1/2 in |
Outlet Ports |
N/A 3/4 in |
Maximum Inlet Pressure |
N/A 150 psig |
Height |
N/A 80 in |
Width |
N/A 68 in |
Depth |
N/A 33 in |
Common Applications
N/A
Beer & Wine Manufacturing & Storage |
Why do you need a GN2 System
N/A
75% to 92% Cost Savings |
System Operation
N/A
The earth’s atmosphere is comprised of approximately 78% nitrogen and 21% oxygen. Once atmospheric air is compressed, its pressure is increased while proportions of nitrogen and oxygen remain unchanged. Once the air is compressed it must be filtered and dried prior to its introduction to the GN2 system. |
Features & Options
N/A
|
Note
N/A
Custom designed, larger capacity or non standard purity systems are available upon request |