VA 570 is supplied with an integrated measuring section. The measuring sections are available in flanged version or with R resp. NPT thread.
A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory).
A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory).
Unit of Measure
Financing
|
Specifications
|
Measuring Range
|
Flange
|
Connection to Different Bus Systems Options
|
Special Measurement Technology Features
|
Special Mechanical Features
|
Additional Information
Specifications
Measuring Range |
N/A Up to 164 ft/s, Low-Speed Version Up to 304 ft/s, Standard Version Up to 607 ft/s, Maximum Version Up to 735 ft/s, High-Speed Version |
Note for Measuring Range |
N/A All measured values related to DIN 1343 standard conditions 32 ºF and 14.7 psi ex works. |
Accuracy |
N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) |
Accuracy on Request |
N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) |
Accuracy Indications |
N/A Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 6 bar |
Repeatability |
N/A 0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section) |
Measuring Principle |
N/A Thermal Mass Flow Sensor |
Response Time |
N/A t 90 <3 sec |
Operating/Ambient Temperature Range |
N/A -4 to 158 ºF |
Media Temperature Range |
N/A -4 to 356 ºF |
Media Temperature Range (ATEX Version) |
N/A -4 to 248 ºF |
Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis |
N/A Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc. |
Standard Outputs |
N/A 1 x 4 to 20 mA Analog Output (Electrically Not Isolated) Pulse Output RS 485 (Modbus-RTU) |
Optional Outputs |
N/A 2 x 4 to 20 mA Active HART M-Bus Mod- bus TCP Profibus DP Profinet |
Burden |
N/A <500 Ω |
Additional Average Value Calculation |
N/A For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value |
Protection Class |
N/A Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90°C Db Ingress Protection (IP 67) |
Housing Material |
N/A Die-Cast Aluminum |
Sensor Tube Material |
N/A Stainless Steel 1.4404 |
Operating Pressure |
N/A 232 psi |
Special Version Operating Pressure |
N/A 580 psi |
Direct Current (DC) Supply Voltage |
N/A 18 to 36 V |
Power Supply |
N/A 5 W |
Approval |
N/A ATEX II 2G Ex db IIC T4 Gb ATEX II 2D Ex tb IIIC T90 ºC Db DVGW |
Measuring Range
Low-Speed Air Flow (164 Feet Per Seconds (ft/s)) |
N/A 765 L/min450 ft³/min |
Standard Air Flow (304 Feet Per Seconds (ft/s)) |
N/A 1420 m³/h835 ft³/min |
Maximum Air Flow (607 Feet Per Seconds (ft/s)) |
N/A 2840 m³/h1670 ft³/min |
High-Speed Air Flow (735 Feet Per Seconds (ft/s)) |
N/A 3440 m³/h2025 ft³/min |
Note for Air Flow |
N/A Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi |
Low-Speed Argon (Ar) Flow (164 Feet Per Seconds (ft/s)) |
N/A 1200 L/min705 ft³/min |
Standard Argon (Ar) Flow (304 Feet Per Seconds (ft/s)) |
N/A 2225 m³/h1310 ft³/min |
Maximum Argon (Ar) Flow (607 Feet Per Seconds (ft/s)) |
N/A 4440 m³/h2615 ft³/min |
High-Speed Argon (Ar) Flow (735 Feet Per Seconds (ft/s)) |
N/A 5380 m³/h3165 ft³/min |
Note for Argon (Ar) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Carbon Dioxide (CO2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 760 L/min445 ft³/min |
Standard Carbon Dioxide (CO2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 1405 m³/h825 ft³/min |
Maximum Carbon Dioxide (CO2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 2810 m³/h1655 ft³/min |
High-Speed Carbon Dioxide (CO2) Flow (735 Feet Per Seconds (ft/s) |
N/A 3405 m³/h2000 ft³/min |
Note for Carbon Dioxide (CO2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrogen (N2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 705 L/min415 ft³/min |
Standard Nitrogen (N2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 1305 m³/h770 ft³/min |
Maximum Nitrogen (N2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 2610 m³/h1535 ft³/min |
High-Speed Nitrogen (N2) Flow (735 Feet Per Seconds (ft/s)) |
N/A 3165 m³/h1860 ft³/min |
Note for Nitrogen (N2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Oxygen (O2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 730 L/min430 ft³/min |
Standard Oxygen (O2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 1355 m³/h795 ft³/min |
Maximum Oxygen (O2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 2710 m³/h1590 ft³/min |
High-Speed Oxygen (O2) Flow (735 Feet Per Seconds (ft/s)) |
N/A 3280 m³/h1930 ft³/min |
Note for Oxygen (O2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrous Oxide (N2O) Flow (164 Feet Per Seconds (ft/s)) |
N/A 750 L/min440 ft³/min |
Standard Nitrous Oxide (N2O) Flow (304 Feet Per Seconds (ft/s)) |
N/A 1395 m³/h820 ft³/min |
Maximum Nitrous Oxide (N2O) Flow (607 Feet Per Seconds (ft/s)) |
N/A 2785 m³/h1640 ft³/min |
High-Speed Nitrous Oxide (N2O) Flow (735 Feet Per Seconds (ft/s)) |
N/A 3375 m³/h1985 ft³/min |
Note for Nitrous Oxide (N2O) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Natural Gas (NG) Flow (164 Feet Per Seconds (ft/s)) |
N/A 450 L/min265 ft³/min |
Standard Natural Gas (NG) Flow (304 Feet Per Seconds (ft/s)) |
N/A 840 m³/h495 ft³/min |
Maximum Natural Gas (NG) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1680 m³/h985 ft³/min |
High-Speed Natural Gas (NG) Flow (735 Feet Per Seconds (ft/s)) |
N/A 2035 m³/h1195 ft³/min |
Note for Natural Gas (NG) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Flange
Flange Pipe Size |
N/A 3 in |
Flange Outer Pipe Diameter |
N/A 88.9 mm |
Flange Inner Pipe Diameter |
N/A 80.9 mm |
Dimension L (Flange) |
N/A 18.7 in |
Note for Dimension L (Flange) |
N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. |
Dimension L1 (Flange) |
N/A 10.83 in |
Dimension H (Flange) |
N/A 12.91 in |
Dimension H1 (Flange) |
N/A 8.98 in |
Diameter D (Flange) |
N/A 200 mm |
Diameter K (Flange) |
N/A 160 mm |
Number of Diameter L (Flange) |
N/A 8 |
Diameter L (Flange) |
N/A 18 mm |
Connection to Different Bus Systems Options
Connection to Different Bus Systems Options |
N/A
There are different options available for connection to modern Bus systems:
|
Special Measurement Technology Features
Special Measurement Technology Features |
N/A
|
Special Mechanical Features
Special Mechanical Features |
N/A
|