VA 570 is supplied with an integrated measuring section. The measuring sections are available in flanged version or with R resp. NPT thread.
A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory).
A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory).
Unit of Measure
Financing
|
Specifications
|
Measuring Range
|
Flange
|
Connection to Different Bus Systems Options
|
Special Measurement Technology Features
|
Special Mechanical Features
|
Additional Information
Specifications
Measuring Range |
N/A Up to 164 ft/s, Low-Speed Version Up to 304 ft/s, Standard Version Up to 607 ft/s, Maximum Version Up to 735 ft/s, High-Speed Version |
Note for Measuring Range |
N/A All measured values related to DIN 1343 standard conditions 32 ºF and 14.7 psi ex works. |
Accuracy |
N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) |
Accuracy on Request |
N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) |
Accuracy Indications |
N/A Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 6 bar |
Repeatability |
N/A 0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section) |
Measuring Principle |
N/A Thermal Mass Flow Sensor |
Response Time |
N/A t 90 <3 sec |
Operating/Ambient Temperature Range |
N/A -4 to 158 ºF |
Media Temperature Range |
N/A -4 to 356 ºF |
Media Temperature Range (ATEX Version) |
N/A -4 to 248 ºF |
Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis |
N/A Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc. |
Standard Outputs |
N/A 1 x 4 to 20 mA Analog Output (Electrically Not Isolated) Pulse Output RS 485 (Modbus-RTU) |
Optional Outputs |
N/A 2 x 4 to 20 mA Active HART M-Bus Mod- bus TCP Profibus DP Profinet |
Burden |
N/A <500 Ω |
Additional Average Value Calculation |
N/A For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value |
Protection Class |
N/A Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90°C Db Ingress Protection (IP 67) |
Housing Material |
N/A Die-Cast Aluminum |
Sensor Tube Material |
N/A Stainless Steel 1.4404 |
Operating Pressure |
N/A 232 psi |
Special Version Operating Pressure |
N/A 580 psi |
Direct Current (DC) Supply Voltage |
N/A 18 to 36 V |
Power Supply |
N/A 5 W |
Approval |
N/A ATEX II 2G Ex db IIC T4 Gb ATEX II 2D Ex tb IIIC T90 ºC Db DVGW |
Measuring Range
Low-Speed Air Flow (164 Feet Per Seconds (ft/s)) |
N/A 320 L/min190 ft³/min |
Standard Air Flow (304 Feet Per Seconds (ft/s)) |
N/A 600 m³/h350 ft³/min |
Maximum Air Flow (607 Feet Per Seconds (ft/s)) |
N/A 1195 m³/h700 ft³/min |
High-Speed Air Flow (735 Feet Per Seconds (ft/s)) |
N/A 1450 m³/h850 ft³/min |
Note for Air Flow |
N/A Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi |
Low-Speed Argon (Ar) Flow (164 Feet Per Seconds (ft/s)) |
N/A 505 L/min295 ft³/min |
Standard Argon (Ar) Flow (304 Feet Per Seconds (ft/s)) |
N/A 935 m³/h550 ft³/min |
Maximum Argon (Ar) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1870 m³/h1100 ft³/min |
High-Speed Argon (Ar) Flow (735 Feet Per Seconds (ft/s)) |
N/A 2265 m³/h1330 ft³/min |
Note for Argon (Ar) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Carbon Dioxide (CO2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 320 L/min185 ft³/min |
Standard Carbon Dioxide (CO2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 590 m³/h345 ft³/min |
Maximum Carbon Dioxide (CO2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1185 m³/h695 ft³/min |
High-Speed Carbon Dioxide (CO2) Flow (735 Feet Per Seconds (ft/s) |
N/A 1430 m³/h840 ft³/min |
Note for Carbon Dioxide (CO2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrogen (N2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 295 L/min175 ft³/min |
Standard Nitrogen (N2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 550 m³/h320 ft³/min |
Maximum Nitrogen (N2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1100 m³/h645 ft³/min |
High-Speed Nitrogen (N2) Flow (735 Feet Per Seconds (ft/s)) |
N/A 1330 m³/h780 ft³/min |
Note for Nitrogen (N2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Oxygen (O2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 305 L/min180 ft³/min |
Standard Oxygen (O2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 570 m³/h335 ft³/min |
Maximum Oxygen (O2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1140 m³/h670 ft³/min |
High-Speed Oxygen (O2) Flow (735 Feet Per Seconds (ft/s)) |
N/A 1380 m³/h810 ft³/min |
Note for Oxygen (O2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrous Oxide (N2O) Flow (164 Feet Per Seconds (ft/s)) |
N/A 315 L/min185 ft³/min |
Standard Nitrous Oxide (N2O) Flow (304 Feet Per Seconds (ft/s)) |
N/A 585 m³/h345 ft³/min |
Maximum Nitrous Oxide (N2O) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1170 m³/h690 ft³/min |
High-Speed Nitrous Oxide (N2O) Flow (735 Feet Per Seconds (ft/s)) |
N/A 1420 m³/h835 ft³/min |
Note for Nitrous Oxide (N2O) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Natural Gas (NG) Flow (164 Feet Per Seconds (ft/s)) |
N/A 190 L/min110 ft³/min |
Standard Natural Gas (NG) Flow (304 Feet Per Seconds (ft/s)) |
N/A 355 m³/h205 ft³/min |
Maximum Natural Gas (NG) Flow (607 Feet Per Seconds (ft/s)) |
N/A 705 m³/h415 ft³/min |
High-Speed Natural Gas (NG) Flow (735 Feet Per Seconds (ft/s)) |
N/A 855 m³/h500 ft³/min |
Note for Natural Gas (NG) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Flange
Flange Pipe Size |
N/A 2 in |
Flange Outer Pipe Diameter |
N/A 60.3 mm |
Flange Inner Pipe Diameter |
N/A 53.1 mm |
Dimension L (Flange) |
N/A 18.7 in |
Note for Dimension L (Flange) |
N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. |
Dimension L1 (Flange) |
N/A 10.83 in |
Dimension H (Flange) |
N/A 11.81 in |
Dimension H1 (Flange) |
N/A 8.98 in |
Diameter D (Flange) |
N/A 165 mm |
Diameter K (Flange) |
N/A 125 mm |
Number of Diameter L (Flange) |
N/A 8 |
Diameter L (Flange) |
N/A 18 mm |
Connection to Different Bus Systems Options
Connection to Different Bus Systems Options |
N/A
There are different options available for connection to modern Bus systems:
|
Special Measurement Technology Features
Special Measurement Technology Features |
N/A
|
Special Mechanical Features
Special Mechanical Features |
N/A
|