Measuring Range |
N/A Up to 164 ft/s, Low-Speed Version Up to 304 ft/s, Standard Version Up to 607 ft/s, Maximum Version Up to 735 ft/s, High-Speed Version |
Note for Measuring Range |
N/A All measured values related to DIN 1343 standard conditions 32 ºF and 14.7 psi ex works. |
Accuracy |
N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) |
Accuracy on Request |
N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) |
Accuracy Indications |
N/A Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 6 bar |
Repeatability |
N/A 0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section) |
Measuring Principle |
N/A Thermal Mass Flow Sensor |
Response Time |
N/A t 90 <3 sec |
Operating/Ambient Temperature Range |
N/A -4 to 158 ºF |
Media Temperature Range |
N/A -4 to 356 ºF |
Media Temperature Range (ATEX Version) |
N/A -4 to 248 ºF |
Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis |
N/A Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc. |
Standard Outputs |
N/A 1 x 4 to 20 mA Analog Output (Electrically Not Isolated) Pulse Output RS 485 (Modbus-RTU) |
Optional Outputs |
N/A 2 x 4 to 20 mA Active HART M-Bus Mod- bus TCP Profibus DP Profinet |
Burden |
N/A <500 Ω |
Additional Average Value Calculation |
N/A For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value |
Protection Class |
N/A Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90°C Db Ingress Protection (IP 67) |
Housing Material |
N/A Die-Cast Aluminum |
Sensor Tube Material |
N/A Stainless Steel 1.4404 |
Operating Pressure |
N/A 232 psi |
Special Version Operating Pressure |
N/A 580 psi |
Direct Current (DC) Supply Voltage |
N/A 18 to 36 V |
Power Supply |
N/A 5 W |
Approval |
N/A ATEX II 2G Ex db IIC T4 Gb ATEX II 2D Ex tb IIIC T90 ºC Db DVGW |
Low-Speed Air Flow (164 Feet Per Seconds (ft/s)) |
N/A 320 L/min190 ft³/min |
Standard Air Flow (304 Feet Per Seconds (ft/s)) |
N/A 600 m³/h350 ft³/min |
Maximum Air Flow (607 Feet Per Seconds (ft/s)) |
N/A 1195 m³/h700 ft³/min |
High-Speed Air Flow (735 Feet Per Seconds (ft/s)) |
N/A 1450 m³/h850 ft³/min |
Note for Air Flow |
N/A Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi |
Low-Speed Argon (Ar) Flow (164 Feet Per Seconds (ft/s)) |
N/A 505 L/min295 ft³/min |
Standard Argon (Ar) Flow (304 Feet Per Seconds (ft/s)) |
N/A 935 m³/h550 ft³/min |
Maximum Argon (Ar) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1870 m³/h1100 ft³/min |
High-Speed Argon (Ar) Flow (735 Feet Per Seconds (ft/s)) |
N/A 2265 m³/h1330 ft³/min |
Note for Argon (Ar) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Carbon Dioxide (CO2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 320 L/min185 ft³/min |
Standard Carbon Dioxide (CO2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 590 m³/h345 ft³/min |
Maximum Carbon Dioxide (CO2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1185 m³/h695 ft³/min |
High-Speed Carbon Dioxide (CO2) Flow (735 Feet Per Seconds (ft/s) |
N/A 1430 m³/h840 ft³/min |
Note for Carbon Dioxide (CO2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrogen (N2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 295 L/min175 ft³/min |
Standard Nitrogen (N2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 550 m³/h320 ft³/min |
Maximum Nitrogen (N2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1100 m³/h645 ft³/min |
High-Speed Nitrogen (N2) Flow (735 Feet Per Seconds (ft/s)) |
N/A 1330 m³/h780 ft³/min |
Note for Nitrogen (N2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Oxygen (O2) Flow (164 Feet Per Seconds (ft/s)) |
N/A 305 L/min180 ft³/min |
Standard Oxygen (O2) Flow (304 Feet Per Seconds (ft/s)) |
N/A 570 m³/h335 ft³/min |
Maximum Oxygen (O2) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1140 m³/h670 ft³/min |
High-Speed Oxygen (O2) Flow (735 Feet Per Seconds (ft/s)) |
N/A 1380 m³/h810 ft³/min |
Note for Oxygen (O2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrous Oxide (N2O) Flow (164 Feet Per Seconds (ft/s)) |
N/A 315 L/min185 ft³/min |
Standard Nitrous Oxide (N2O) Flow (304 Feet Per Seconds (ft/s)) |
N/A 585 m³/h345 ft³/min |
Maximum Nitrous Oxide (N2O) Flow (607 Feet Per Seconds (ft/s)) |
N/A 1170 m³/h690 ft³/min |
High-Speed Nitrous Oxide (N2O) Flow (735 Feet Per Seconds (ft/s)) |
N/A 1420 m³/h835 ft³/min |
Note for Nitrous Oxide (N2O) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Natural Gas (NG) Flow (164 Feet Per Seconds (ft/s)) |
N/A 190 L/min110 ft³/min |
Standard Natural Gas (NG) Flow (304 Feet Per Seconds (ft/s)) |
N/A 355 m³/h205 ft³/min |
Maximum Natural Gas (NG) Flow (607 Feet Per Seconds (ft/s)) |
N/A 705 m³/h415 ft³/min |
High-Speed Natural Gas (NG) Flow (735 Feet Per Seconds (ft/s)) |
N/A 855 m³/h500 ft³/min |
Note for Natural Gas (NG) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Flange Pipe Size |
N/A 2 in |
Flange Outer Pipe Diameter |
N/A 60.3 mm |
Flange Inner Pipe Diameter |
N/A 53.1 mm |
Dimension L (Flange) |
N/A 18.7 in |
Note for Dimension L (Flange) |
N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. |
Dimension L1 (Flange) |
N/A 10.83 in |
Dimension H (Flange) |
N/A 11.81 in |
Dimension H1 (Flange) |
N/A 8.98 in |
Diameter D (Flange) |
N/A 165 mm |
Diameter K (Flange) |
N/A 125 mm |
Number of Diameter L (Flange) |
N/A 8 |
Diameter L (Flange) |
N/A 18 mm |
Connection to Different Bus Systems Options |
N/A
There are different options available for connection to modern Bus systems:
|
Special Measurement Technology Features |
N/A
|
Special Mechanical Features |
N/A
|