Specifications
Brands |
N/A Kaeser Compressors |
Model |
N/A KBD 1500 |
Working Pressure |
N/A 100 psig |
Inlet Flow at 100 Pounds Per Square Inch Gauge (psig) Pressure and 100 ºF Temperature |
N/A 1500 scfm |
Blower Flow Rate |
N/A 281 scfm |
Normal Blower Flow Power |
N/A 10 hp |
Average Blower Power |
N/A 7.8 kW |
Normal Heater Power |
N/A 28 kW |
Average Heater Power |
N/A 19.3 kW |
Approximate Weight |
N/A 5359 lb |
Inlet/Outlet Connections Type |
N/A Flange |
Inlet/Outlet Connection Size |
N/A 3 in |
Pre-Filter (KB Series) |
N/A 1875 scfm |
High-Temp After-Filter (HTA Series) |
N/A 1800 scfm |
Total Replacement Desiccant |
N/A 2518 lb |
Standard |
N/A National Electrical Manufacturers Association (NEMA) 4 |
Features and Advantages
Features and Advantages |
N/A
|
Additional Information
N/A
Solid state logic accurately controls inlet and purge valves which direct wet compressed air to the regenerated tower, and heated ambient air to the tower in need of regeneration. The process of adsorption and desorption can be repeated several thousand times before the desiccant must be replaced. |
Note
Note |
N/A
Average Heater kW (fixed cycle) = [kW required to produce 280 ºF temperature rise] x [235 min. max heat time] / [240 min drying time]. Average Blower kW (fixed cycle) = [Blower kW] x [235 min. max heat time] / [240 min dryer time]. Average Dryer kW (fixed cycle) = [Average Heater kW] + [Average Blower kW] Actual kW is less and proportional to the average water load presented to the dryer. |