Oil Check 500 - The monitoring system for permanent highly precise measurement of the vaporous residual oil content compressed air, nitrogen and gases
"Forced Pressure Variation" for long-term stable measurement results - Auto-calibration
Thanks to the innovative "Forced Pressure Variation" measuring method, the Oil Check 500 generates reference gas internally in different mass concentrations. With the help of this process, which is intellectually protected by CS INSTRUMENTS, components in the measurement signal caused by ageing or contamination, in particular long-term drifts, can be compensated. No wearing parts such as activated carbon filters are necessary for the generation of zero air. The result is a low-maintenance and long-term stable measurement
Specifications
Measured Medium |
N/A
Compressed air, nitrogen, (free from aggressive, corrosive, acid, toxic, flammable and oxidizing components). Further gases on request |
Measuring Unit |
N/A Residual oil content in mg oil/norm m³ referred to 14.5 psi [abs], +68 F, 0% relative humidity, in accordance with ISO 8573-1 |
Identifiable Substances |
N/A Aromatic Hydrocarbons Functional Hydrocarbons Hydrocarbons |
Ambient Temperature |
N/A +68 to +113 ºF |
Relative Humidity without Condensation |
N/A ≤ 75 % |
Compressed Air Temperature |
N/A +68 to +113 ºF |
Operational Overpressure1 | N/A 43.5 to 130.5 psi |
Humidity of Measured Gas |
N/A ≤ 40% relative humidity, pressure dew point maximum +50 ºF, non-condensable humidity |
Compressed Air Connection |
N/A G-1/4 in. Female Thread According to International Organization for Standardization (ISO) 228-1 |
Measured Values |
N/A mg/norm m³, pressure and temperature compensated residual oil vapor content |
Measuring Range2 | N/A 0.001 to 5 mg/m³ |
Detection limit (Residual Oil) |
N/A 0.001 mg/m³ |
Approximate Flow of Measuring Gas |
N/A 0.042 ft³/min |
Note for Approximate Flow of Measuring Gas |
N/A Referred to to 14.5 psi [abs] and +68 F, (atmospheric conditions) |
Alternating Current (AC) Voltage |
N/A 100 to 240 V |
Phase |
N/A 1 |
Grounding |
N/A Protective Earth (PE) |
Frequency |
N/A 50 to 60 Hz |
Voltage Tolerance |
N/A ±10 % |
Digital Output |
N/A Ethernet Via DS 400/500 RS 485 Interface (Modbus-Remote Terminal Unit (RTU)) |
Analog Output Current (Electrically Isolated) |
N/A 4 to 20 mA |
Optional Output |
N/A 2 x 4...20 mA analog output (electrically isolated), 2 alarm relays for external alarm unit, alarm values freely adjustable |
Operating Hours Counter |
N/A Integrated |
Field of Application
Field of Application |
N/A After activated carbon filter, after activated carbon adsorber, after oil-free compressor, always with connected upstream filtration and dryer |
Stationary Solution
Stationary Solution |
N/A
Item # - 0554 8040 Description - CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places Item # - 0699 0080 Description - Residual oil measurement: Oil Check 500 - residual oil measurement of the vaporous oil content from 0,001…5 mg/m³, 43.5 ... 130.5 psi. High-precision PID-Sensor, innovative ”Forced Pressure Variation“ measuring method, with integrated display, with 4...20 mA analog output and digital Modbus RTU interface, incl. calibration certificate Item # - Z699 0078 Description - Options: Integrated heating element for the stationary Oil Check 500. Keeps the gas temperature constantly above 68 ºF. Recommended for installations where the room temperature may fall below 68 ºF. Item # - Z699 0178 Description - 2x 4...20 mA analog output (electrically isolated) Item # - Z699 0175 Description - Sampling system Oil Check 500: Sampling system consisting of 1/2" ball valve (oil- and grease-free), 3.28 ft stainless steel tube 6x1 mm (oil- and grease-free), clamp screwing (oil- and grease-free) Item # - Z699 0174 Description - Alternative: Portable sampling system consisting of 6.56 ft PTFE hose, quick coupling (oil- and grease-free) Item # - Z699 0076 Description - Options for systems > 130.5 psi: Pressure reducer (oil- and grease-free), input pressure max. 4350 psi, output pressure up to 130.5 psi Item # - 0553 0104 Description - Connection cable for probes 16 ft with open ends Item # - 0699 0040 Description - PC 400 particle counter up to 0.1 ?m for compressed air and gases, incl. pressure reducer/sampling hose, calibration certificate, Modbus-RTU interface Item # - 0553 0104 Description - Connection cable for probes, 16 ft with open ends Item # - 0699 0510 Description - FA 510 dew point sensor for adsorption dryers -112 ... 68 Ftd incl. factory certificate, 4…20 mA analog output (3-wire connection) and Modbus-RTU interface Item # - 0699 3390 Description - Standard measuring chamber up to 232 psi Item # - 0553 0104 Description - Connection cable for VA/FA series, 16 ft with open ends Item # - Z699 0077 Description - External alarm unit, wired ready to plug in, for direct connection to the Oil Check 500 with 16 ft cable (buzzer and continuous red light) |
Mobile Solution with DS 500, Oil Check 500, PC 400, FA 510
Mobile Solution with DS 500, Oil Check 500, PC 400, FA 510 |
N/A
Item # - 0554 8040 Description - CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places Item # - 0699 0080 Description - Residual oil measurement: Oil Check 500 - residual oil measurement of the vaporous oil content from 0,001…5 mg/m³, 43.5 .... 130.5 psi. High-precision PID-Sensor, innovative “Forced Pressure Variation“ measuring method, with integrated display, with 4...20 mA analog output and digital Modbus RTU interface, incl. calibration certificate Item # - 0554 6017 Description - Mobile transport trolley including roles (outer dimensions: 26.77 x 41.73 x 16.14 inch) (W x H x D) with firmly mounted components of Oil Check 400, PC 400, FA 510 Item # - Z699 0078 Description - Options:Integrated heating element for the stationary Oil Check 500. Keeps the gas temperature constantly above 68 F. Recommended for installations where the room temperature may fall below 68 F. Item # - Z699 7774 Description - Mobile sampling system consisting of 6.56 ft PTFE hose, quick coupling (oil- and grease-free) Item # - 0553 0104 Description - Connection cable for probes, 16 ft with open ends Item # - 0699 0040 Description - PC 400 particle counter up to 0.1 ?m for compressed air and gases, incl. pressure reducer/ sampling hose, calibration certificate, Modbus-RTU interface Item # - 0553 0104 Description - Connection cable for probes, 16 ft with open ends Item # - 0699 0510 Description - FA 510 Dew point sensor, -112 ... +68 Ftd Item # - 0699 3390 Description - Standard measuring chamber Item # - 0553 0104 Description - Connection cable for VA/FA series, 16 ft with open ends |
Features
Features |
N/A
|
Additional Information
N/A
Measure compressed air quality according to ISO 8573 |
- 1 Optional pressure reducer connected upstream for up to 4350 psi
- 2 Higher Measuring Ranges On Request