| Shipping | Tax | Terms Shopping Cart 0 Items Request for Quote 0 Items All Categories > Compressed Air Quality > Oil Check 400 Monitoring Systems > Item # 0699 0070 Download PDF Download PDF Printable Page Email This Page Save To Favorites Please wait… Item # 0699 0070, Oil Check 400 Monitoring System Web Price QUOTE larger image The monitoring system for permanent highly precise measurement of the vaporous residual oil content in compressed airOil Check 400 - Residual oil measurement of the vaporous residual oil content from 0.001 to 2.5 mg/m³, 3 to 16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0 to 10 volts for connection to external chart recorders Financing · Specifications · Field of Application · Dimensions · Advantages · Integrated Chart Recorder DS 400 · Options Financing Approve Payments Finance with Approve Payments Specifications Measured Medium Acid Compressed Air Corrosive Flammable and Oxidizing Components Free From Aggressive Toxic Measuring Unit Residual oil content in mg oil/norm m³ referred to 14.5 psi [abs], +68 F, 0% relative humidity, in accordance with ISO 8573-1 Identifiable Substances Aromatic Hydrocarbons Functional Hydrocarbons Hydrocarbons Ambient Temperature +5 to 45 ºC Relative Humidity without Condensation ≤ 75 % Maximum Pressure Dew Point 10 ºC Compressed Air Temperature +5 to +50 ºF Operational Overpressure1 3 to 16 psi Setting Operational Pressure By means of integrated pressure reducer with display Humidity of Measured Gas ≤ 40% relative humidity, pressure dew point maximum +10 ºC, non-condensable humidity Compressed Air Connection G-1/8 in. Female Thread According to International Organization for Standardization (ISO) 228-1 Measured Values mg/norm m³, pressure and temperature compensated residual oil vapor content Measuring Range 0.001 to 2.5 mg/m³ Detection limit (Residual Oil) 0.001 mg/m³ Approximate Flow of Measuring Gas 1.20 L/min Note for Approximate Flow of Measuring Gas Relative to 1.0 bar [abs] and + 20 °C, in a relaxed state Reference Gas Generation By means of integrated mini catalyst Alternating Current (AC) Voltage 100 to 240 V Phase 1 Grounding Protective Earth (PE) Frequency 50 to 60 Hz Voltage Tolerance ±10 % Outputs 2 Alarm Relays (change 230 VAC 3A) 4…20 mA (on request) Ethernet Interface (Modbus/TCP) RS 485 Interface (Modbus-RTU) Operating Hours Counter Integrated 1 Optional pressure reducer connected upstream for up to 300 psi Field of Application After activated carbon filter, after activated carbon adsorber, after oil-free compressor, always with connected upstream filtration and dryer Dimensions Width 410 mm Height 440 mm Depth 163 mm Approximate Weight 16.3 kg Advantages Advantages at a glance:Permanent, highly precise residual oil measurement (oil vapor) with PID sensor (photo-ionic-detector)Ideal for mobile measurement: The PID sensor is ready for measurement within about 30 minutesMeasuring results with long-term stability due to automatic zero point calibration. The integrated mini catalyst reliably generates a defined reference gas for zero point calibrationIn contrast to measuring systems which generate the “zero air” or reference gas by means of active carbon filters and which are therefore dependent on the ageing and saturation of the active carbon filters, the mini catalyst generates the “zero air” without ageing or wear. There is no change of active carbon filters necessaryEasy sampling via PTFE hose or stainless steel pipe Integrated Chart Recorder DS 400 Data logger for long-term monitoringDisplay shows trend curves (online and history curves available)Zoom function directly on the touch screenIntegrated Ethernet interface (Modbus/TCP) and RS 485 interface (Modbus-RTU) for data transfer to superordinate controls2 alarm relays (changeover contact 230 VAC, 3A) - threshold values freely adjustableEasy operation via 3.5" touchscreen Options 0554 8040, CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places Z500 4001, 2 additional sensor inputs for analogue sensors (pressure sensors, temperature sensors etc.) Z500 4002, Integrated data logger for 100 million measured values Z500 4004, Integrated Ethernet and RS 485 interface Z500 4005, Integrated webserver Z699 0071, Option: DS 400 chart recorder integrated into Oil Check 400 Z699 0074, Portable sampling system consisting of 2 m PTFE hose, quick coupling (oil- and grease-free) Z699 0075, Sampling system Oil Check 400:Sampling system consisting of 1/2" ball valve (oil- and grease free), 1 m stainless steel tube 6x1 mm (oil- and grease-free), clamp screwing (oil- and grease-free) Z699 0076, For systems > 16 bar: Pressure reducer (oil- and grease-free), input pressure max. 300 bar, output pressure up to 10 bar MORE IMAGES · Certificates DOWNLOADS Datasheet for Oil Check 400 Monitoring Systems (PDF, 376KB) Maintain Your Air Compressor Learn more about maintaining your air compressor by downloading our eBook on air compressor maintenance. Download eBook