Item # 0699 0070, Oil Check 400 Monitoring System
|
Web Price QUOTE
|
|
|
The monitoring system for permanent highly precise measurement of the vaporous residual oil content in compressed air
Oil Check 400 - Residual oil measurement of the vaporous residual oil content from 0.001 to 2.5 mg/m³, 3 to 16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0 to 10 volts for connection to external chart recorders
|
|
|
|
|
|
|
|
|
After activated carbon filter, after activated carbon adsorber, after oil-free compressor, always with connected upstream filtration and dryer
|
|
|
|
|
|
Advantages at a glance:- Permanent, highly precise residual oil measurement (oil vapor) with PID sensor (photo-ionic-detector)
- Ideal for mobile measurement: The PID sensor is ready for measurement within about 30 minutes
- Measuring results with long-term stability due to automatic zero point calibration. The integrated mini catalyst reliably generates a defined reference gas for zero point calibration
- In contrast to measuring systems which generate the “zero air” or reference gas by means of active carbon filters and which are therefore dependent on the ageing and saturation of the active carbon filters, the mini catalyst generates the “zero air” without ageing or wear. There is no change of active carbon filters necessary
- Easy sampling via PTFE hose or stainless steel pipe
|
|
|
|
- Data logger for long-term monitoring
- Display shows trend curves (online and history curves available)
- Zoom function directly on the touch screen
- Integrated Ethernet interface (Modbus/TCP) and RS 485 interface (Modbus-RTU) for data transfer to superordinate controls
- 2 alarm relays (changeover contact 230 VAC, 3A) - threshold values freely adjustable
- Easy operation via 3.5" touchscreen
|
|
|
|
0554 8040, CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places
|
Z500 4001, 2 additional sensor inputs for analogue sensors (pressure sensors, temperature sensors etc.)
|
Z500 4002, Integrated data logger for 100 million measured values
|
Z500 4004, Integrated Ethernet and RS 485 interface
|
Z500 4005, Integrated webserver
|
Z699 0071, Option: DS 400 chart recorder integrated into Oil Check 400
|
Z699 0074, Portable sampling system consisting of 2 m PTFE hose, quick coupling (oil- and grease-free)
|
Z699 0075, Sampling system Oil Check 400: Sampling system consisting of 1/2" ball valve (oil- and grease free), 1 m stainless steel tube 6x1 mm (oil- and grease-free), clamp screwing (oil- and grease-free)
|
Z699 0076, For systems > 16 bar: Pressure reducer (oil- and grease-free), input pressure max. 300 bar, output pressure up to 10 bar
|
|
|
|
|
|
|
|
 |
|
|
|