The AIR-SAVER G2 is installed in the compressed air line after the air receiver. The AIR-SAVER G2 opens and closes the air supply to the factory, based on customer specific working shifts.
A typical compressed air system has air loss through pipe work connections, leaking float type drains, etc.
The AIR-SAVER G2 will open the ball valve at the beginning of a working shift and close the ball valve when the working shift is over. From that point on, all compressed air will remain in the air receiver until the next working shift, rather than being lost through leakages.
The clever and versatile programming feature allows for customer specific settings and is totally adaptable to the working hours of each individual factory.
The AIR-SAVER G2 can be installed in all pipe line systems up to G2. Remote switching kits are available to operate the AIR-SAVER G2 from a distance.
A typical compressed air system has air loss through pipe work connections, leaking float type drains, etc.
The AIR-SAVER G2 will open the ball valve at the beginning of a working shift and close the ball valve when the working shift is over. From that point on, all compressed air will remain in the air receiver until the next working shift, rather than being lost through leakages.
The clever and versatile programming feature allows for customer specific settings and is totally adaptable to the working hours of each individual factory.
The AIR-SAVER G2 can be installed in all pipe line systems up to G2. Remote switching kits are available to operate the AIR-SAVER G2 from a distance.
Unit of Measure
Financing
|
Specifications
|
Technical Specification
|
Supply Voltage Options
|
Commercial Benefits
|
Technical Advantages
|
Note
Specifications
Brands |
N/A Jorc |
Industry Standards/Certifications |
N/A CE NEN - EN - ISO 9001:2015 Certified RoHS |
Technical Specification
Pressure Range |
N/A 0 to 230 psi0 to 16 bar |
Opening/Closing Duration Per 90 Degree (º) |
N/A 105 seconds |
Medium Temperature |
N/A 34 to 212 ºF1 to 100 ºC |
Ambient Temperature |
N/A 1 to 50 ºC |
Illuminated Liquid Crystal Display (LCD) |
N/A Battery Life Indicating Day Time Valve Status |
Programmable Options |
N/A Maximum 100 Switching Point to be Distributed Over 1-7 days Week Planner |
Inlet/Outlet Connections |
N/A 2 in. British Standard Pipe (BSP) National Pipe Thread (NPT) |
Valve Housing Material |
N/A Brass Nickel Plated |
Serviceable Valve |
N/A true |
Manual Override |
N/A true |
Remote Controllable |
N/A true |
Environmental Protection |
N/A National Electrical Manufacturers Association (NEMA13) (Ingress Protection (IP54)) |
Supply Voltage Options
Alternating Current (AC) Voltage |
N/A 115 V230 V |
Frequency |
N/A 50 Hz60 Hz |
Note for Supply Voltage Options |
N/A Please Indicate |
Commercial Benefits
Commercial Benefits |
N/A
|
Technical Advantages
Technical Advantages |
N/A
|
Note
Note |
N/A Information provided herewith is believed to be accurate and reliable. However, no responsibility is assumed for its use or for any infringement of patents or rights of others, which may result from its use. In addition, Jorc reserves the right to revise information without notice and without incurring any obligation. |