Titan Large Capacity Industrial Process Chillers
Process Chillers
- Refrigerant R410A
- Precise temperature control for any industrial application
- Electronic Expansion thermostatic valve
- Separated compressor compartment with removeable panels
- Refrigerant high and low pressure gauges
Unit of Measure
Items |
/Asset/a8655.jpg IPC-0532 53.2 Ton (t) Cooling Capacity Titan Large Capacity Industrial Process Chiller Web Price Quote
|
/Asset/a8655.jpg IPC-0598 59.8 Ton (t) Cooling Capacity Titan Large Capacity Industrial Process Chiller Web Price Quote
|
/Asset/a8655.jpg IPC-0756 75.6 Ton (t) Cooling Capacity Titan Large Capacity Industrial Process Chiller Web Price Quote
|
/Asset/a8655.jpg IPC-0946 94.6 Ton (t) Cooling Capacity Titan Large Capacity Industrial Process Chiller Web Price Quote
|
/Asset/a8655.jpg IPC-1060 106 Ton (t) Cooling Capacity Titan Large Capacity Industrial Process Chiller Web Price Quote
|
|||||
Brands | N/A IPC Industrial Process Cooling | |||||||||
Cooling Capacity | N/A 53.2 ton638,070 Btu/hr | N/A 59.8 ton717,480 Btu/hr | N/A 75.6 ton907,629 Btu/hr | N/A 94.6 ton1,135,901 Btu/hr | N/A 106 ton1,272,728 Btu/hr | |||||
Fluid Connections | N/A 3 inMale Victaulic | N/A 3 inMale Victaulic | N/A 3 inMale Victaulic | N/A 4 inMale Victaulic | N/A 4 inMale Victaulic | |||||
Flow, Nominal | N/A 125 gpm | N/A 145 gpm | N/A 180 gpm | N/A 225 gpm | N/A 250 gpm | |||||
Head Pressure, Nominal | N/A 40 psi | |||||||||
Reservoir Capacity | N/A 132 gal | N/A 132 gal | N/A 132 gal | N/A 200 gal | N/A 200 gal | |||||
Power Supply Voltage | N/A 460 V | |||||||||
Power Supply Phase | N/A 3 | |||||||||
Power Supply Frequency | N/A 60 Hz | |||||||||
Full Load Current | N/A 196.0 A | N/A 227.0 A | N/A 257.0 A | N/A 315.0 A | N/A 365.0 A | |||||
Length | N/A 31 in | |||||||||
Width | N/A 23 in | |||||||||
Height | N/A 18 in | |||||||||
Installed Weight | N/A 6,846 lb | N/A 6,941 lb | N/A 7,061 lb | N/A 9,293 lb | N/A 9,393 lb | |||||
Dry Weight | N/A 5,747 lb | N/A 5,908 lb | N/A 6,029 lb | N/A 7,835 lb | N/A 7,935 lb | |||||
Fluid Out/In Temperature | N/A 45 ºF55 ºF | |||||||||
Ambient Temperature | N/A 95 ºF | |||||||||
Minimum Fluid Outlet Temperature | N/A 41 ºF | |||||||||
Maximum Fluid Outlet Temperature | N/A 82 ºF | |||||||||
Maximum Ambient Temperature | N/A 113 ºF | |||||||||
Correction Factor at 30 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.68 | |||||||||
Correction Factor at 35 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.79 | |||||||||
Correction Factor at 40 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.91 | |||||||||
Correction Factor at 45 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1 | |||||||||
Correction Factor at 50 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.09 | |||||||||
Correction Factor at 55 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.19 | |||||||||
Correction Factor at 60 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.27 | |||||||||
Correction Factor at 80 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.11 | |||||||||
Correction Factor at 85 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.08 | |||||||||
Correction Factor at 90 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.04 | |||||||||
Correction Factor at 95 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1 | |||||||||
Correction Factor at 100 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.93 | |||||||||
Correction Factor at 105 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.91 | |||||||||
Correction Factor at 113 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.83 | |||||||||
Correction Factor at 0 Percent (%) Ethylene Glycol | N/A 1 | |||||||||
Correction Factor at 10 Percent (%) Ethylene Glycol | N/A 0.99 | |||||||||
Correction Factor at 20 Percent (%) Ethylene Glycol | N/A 0.98 | |||||||||
Correction Factor at 30 Percent (%) Ethylene Glycol | N/A 0.97 | |||||||||
Correction Factor at 40 Percent (%) Ethylene Glycol | N/A 0.96 | |||||||||
Correction Factor at 45 Percent (%) Ethylene Glycol | N/A 0.95 | |||||||||
Correction Factor at 50 Percent (%) Ethylene Glycol | N/A 0.94 | |||||||||
Refrigerant Type | N/A R410A | |||||||||
Benefits and Advantages |
N/A
Industrial water chillers offer protection to your valuable process equipment - such as spot welders, injection molding equipment, and various other industrial applications. A chiller provides solid protection of your investment twenty-four hours a day, seven day a week during the chiller's lifetime.
|
|||||||||
Applications |
N/A
|
|||||||||
Additional Information | N/A Industrial Process Cooling offers various-sized compact water and oil chillers, as well as large cooling systems to fit industrial applications. | |||||||||
Note | N/A | |||||||||
|