No inlet section necessary - integrated flow straightener - optional pressure sensor

The newly developed VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design. The VA 525 is always used when many machines (compressed air consumers) are to be integrated into an energy monitoring network.

Readout values in the display can be rotated by 180º, e.g. for overhead installation
Unit of Measure
Items
VA 525 Compact Inline Flowmeters for Air and Nitrogen

VA 521 G 1/2 Inch (in) Thread Size Compact Inline Flowmeter
Web Price QUOTE

VA 525 Compact Inline Flowmeters for Air and Nitrogen

VA 521 G 3/4 Inch (in) Thread Size Compact Inline Flowmeter
Web Price QUOTE

VA 525 Compact Inline Flowmeters for Air and Nitrogen

VA 521 G 1 Inch (in) Thread Size Compact Inline Flowmeter
Web Price QUOTE

VA 525 Compact Inline Flowmeters for Air and Nitrogen

VA 521 G 1-1/4 Inch (in) Thread Size Compact Inline Flowmeter
Web Price QUOTE

VA 525 Compact Inline Flowmeters for Air and Nitrogen

VA 521 G 1-1/2 Inch (in) Thread Size Compact Inline Flowmeter
Web Price QUOTE
Description N/A No inlet section necessary - integrated flow straightener - optional pressure sensor

The newly developed VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design. The VA 525 is always used when many machines (compressed air consumers) are to be integrated into an energy monitoring network.

Readout values in the display can be rotated by 180º, e.g. for overhead installation
Approve Payments N/A Finance with Approve Payments

Parameters N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 ºC) in case of gases
Measuring Section N/A DN8 N/A DN15 N/A DN20 N/A DN25 N/A DN32
Thread Size N/A G 1/4 in. N/A G 1/2 in. N/A G 3/4 in. N/A G 1 in. N/A G 1-1/4 in.
Measuring Range Full Scales N/A 105 L/min4 ft³/min N/A 90 m³/h50 ft³/min N/A 170 m³/h100 ft³/min N/A 290 m³/h170 ft³/min N/A 530 m³/h310 ft³/min
Dimension L N/A 135 mm
Dimension B N/A 55 mm N/A 55 mm N/A 55 mm N/A 55 mm N/A 80 mm
Dimension H1 N/A 50 mm N/A 50 mm N/A 50 mm N/A 50 mm N/A 80 mm
Dimension H N/A 109.1 mm N/A 109.1 mm N/A 109.1 mm N/A 109.1 mm N/A 139.1 mm
Dimension A N/A 15 mm N/A 20 mm N/A 20 mm N/A 25 mm N/A 25 mm
Note for Measuring Range N/A Flow measuring ranges VA 525 (max version 185 m/s) for compressed air (ISO 1217:1000 mbar, 20 ºC)
Measuring ranges for other types of gas.
Units Adjustable Via Keys at Display N/A CFM ft/min g/s kg/h kg/min l/s lb/h lb/min m/s m³/h m³/min
Sensor N/A Thermal Mass Flow Sensor
Measured Medium N/A Air
Accuracy N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.)
Accuracy on Request N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.)
Pressure N/A 0 to 232 psi0.15 to 29 psia
Pressure Accuracy N/A 1 %
Operating Temperature N/A -4 to 140 ºF
Operating Pressure N/A Up to 232 psi
Digital Output N/A Modbus-Remote Terminal Unit (RTU) RS 485 Interface
Optional Digital Output N/A Ethernet Interface M-Bus Power over Ethernet (PoE)
Analog Output for Cubic Feet Per Minute (CFM) N/A 4 to 20 mA
Pulse Output N/A 1 pulse per CF or per liter electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay.
Direct Current (DC) Supply Voltage N/A 18 to 36 V
Power Supply N/A 5 W
Burden N/A <500 Ω
Housing Material N/A Polycarbonate
Protection Rating N/A Ingress Protection (IP 65)
Material N/A Aluminum
Connection Thread of Measuring Sections N/A 1/2 to 2 in. National Pipe Thread (NPT) G 1/4 to G 2 in. British Standard Piping (BSP)
Mounting Position N/A Any
Display Shows 2 Values at The Same Time N/A
  • Present flow in m³/h, CFM, SCFM
  • Total consumption (counter reading) in CF, l, lbs
  • Temperature measurement
  • Optional: Pressure measurement
Screw-In Thread N/A Easy installation into the existing pipe due to integrated measuring section (suitable for 1/4", 1/2", 3/4", 1", 1 1/4", 1 1/2" or 2" lines)
Advantages at a Glance N/A
  • Compact, small design - for use in machines, behind maintenance unit on the end user
  • Optionally with conventional analog signals
  • (4 to 20 mA and pulse) or digital interfaces
  • Such as Modbus-RTU, Ethernet (also PoE), M-Bus
  • All interfaces are freely programmable via the display
With a Key Stroke N/A
  • Reset counter reading
  • Select units
  • Parameterise interfaces