No inlet section necessary - integrated flow straightener - optional pressure sensor
The newly developed VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design. The VA 525 is always used when many machines (compressed air consumers) are to be integrated into an energy monitoring network.
Readout values in the display can be rotated by 180º, e.g. for overhead installation
The newly developed VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design. The VA 525 is always used when many machines (compressed air consumers) are to be integrated into an energy monitoring network.
Readout values in the display can be rotated by 180º, e.g. for overhead installation
Unit of Measure
Financing
|
Specifications
|
Measuring Range
|
Display Shows 2 Values at the Same Time
|
Screw-In Thread
|
Advantages at a Glance
|
With a Key Stroke
Specifications
Parameters |
N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 ºC) in case of gases |
Units Adjustable Via Keys at Display |
N/A CFM ft/min g/s kg/h kg/min l/s lb/h lb/min m/s m³/h m³/min |
Sensor |
N/A Thermal Mass Flow Sensor |
Measured Medium |
N/A Air |
Accuracy |
N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) |
Accuracy on Request |
N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) |
Pressure |
N/A 0 to 232 psi0.15 to 29 psia |
Pressure Accuracy |
N/A 1 % |
Operating Temperature |
N/A -4 to 140 ºF |
Operating Pressure |
N/A Up to 232 psi |
Digital Output |
N/A Modbus-Remote Terminal Unit (RTU) RS 485 Interface |
Optional Digital Output |
N/A Ethernet Interface M-Bus Power over Ethernet (PoE) |
Analog Output for Cubic Feet Per Minute (CFM) |
N/A 4 to 20 mA |
Pulse Output |
N/A 1 pulse per CF or per liter electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay. |
Direct Current (DC) Supply Voltage |
N/A 18 to 36 V |
Power Supply |
N/A 5 W |
Burden |
N/A <500 Ω |
Housing Material |
N/A Polycarbonate |
Protection Rating |
N/A Ingress Protection (IP 65) |
Material |
N/A Aluminum |
Connection Thread of Measuring Sections |
N/A 1/2 to 2 in. National Pipe Thread (NPT) G 1/4 to G 2 in. British Standard Piping (BSP) |
Mounting Position |
N/A Any |
Measuring Range
Measuring Section |
N/A DN20 |
Thread Size |
N/A G 3/4 in. |
Measuring Range Full Scales |
N/A 170 m³/h100 ft³/min |
Dimension L |
N/A 135 mm |
Dimension B |
N/A 55 mm |
Dimension H1 |
N/A 50 mm |
Dimension H |
N/A 109.1 mm |
Dimension A |
N/A 20 mm |
Note for Measuring Range |
N/A
Flow measuring ranges VA 525 (max version 185 m/s) for compressed air (ISO 1217:1000 mbar, 20 ºC) Measuring ranges for other types of gas. |
Display Shows 2 Values at the Same Time
Display Shows 2 Values at The Same Time |
N/A
|
Screw-In Thread
Screw-In Thread |
N/A Easy installation into the existing pipe due to integrated measuring section (suitable for 1/4", 1/2", 3/4", 1", 1 1/4", 1 1/2" or 2" lines) |
Advantages at a Glance
Advantages at a Glance |
N/A
|