VA 520 Inline Flowmeters
Flow Thermal
Display shows 2 values at the same time:
- Present flow in m³/h, CFM
- Total consumption (counter reading) in CF
- Temperature measurement
Unit of Measure
Items |
![]() 0695 2521 VA 520 Flowmeter with Integrated DN 15 Measuring Section with Flange Web Price QUOTE
|
![]() 0695 2522 VA 520 Flowmeter with Integrated DN 20 Measuring Section with Flange Web Price QUOTE
|
![]() 0695 2523 VA 520 Flowmeter with Integrated DN 25 Measuring Section with Flange Web Price QUOTE
|
![]() 0695 2526 VA 520 Flowmeter with Integrated DN 32 Measuring Section with Flange Web Price QUOTE
|
![]() 0695 2524 VA 520 Flowmeter with Integrated DN 40 Measuring Section with Flange Web Price QUOTE
|
|||||
Description |
N/A
Display shows 2 values at the same time:
|
|||||||||
Approve Payments |
N/A
Finance with Approve Payments |
|||||||||
Parameters | N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 ºC) in case of gases | |||||||||
Units Adjustable Via Keys at Display | N/A CFM ft/min g/s kg/h kg/min l/s lb/h lb/min m/s m³/h m³/min | |||||||||
Sensor | N/A Thermal Mass Flow Sensor | |||||||||
Measured Medium | N/A Air Gases | |||||||||
Gas Types are Adjustable Over CS Service Software or CS Data Logger | N/A Air Argon CO2 Nitrogen Oxygen | |||||||||
Accuracy | N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) | |||||||||
Accuracy on Request | N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) | |||||||||
Operating Temperature | N/A -22 to 176 ºF | |||||||||
Operating Temperature with Pressure Sensor | N/A -25 to 349 ºF | |||||||||
Operating Pressure | N/A -1 to 232 psi | |||||||||
Optional Pressure | N/A Up to Nominal Pressure (PN) 40 | |||||||||
Digital Output | N/A M-Bus Modbus-Remote Terminal Unit (RTU) Optional: Ethernet Interface (PoE) RS 485 Interface | |||||||||
Analog Output for Cubic Feet Per Minute (CFM) | N/A 4 to 20 mA | |||||||||
Pulse Output | N/A 1 pulse per CF or per liter electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay. | |||||||||
Direct Current (DC) Supply Voltage | N/A 18 to 36 V | |||||||||
Power Supply | N/A 5 W | |||||||||
Burden | N/A <500 Ω | |||||||||
Housing Material | N/A Polycarbonate | |||||||||
Protection Rating | N/A Ingress Protection (IP 65) | |||||||||
Material | N/A Stainless Steel 1.4301 | |||||||||
Mounting Position | N/A Any | |||||||||
Low-Speed Air Flow (164 Feet Per Seconds (ft/s)) | N/A | |||||||||
Standard Air Flow (304 Feet Per Seconds (ft/s)) | N/A | |||||||||
Maximum Air Flow (607 Feet Per Seconds (ft/s)) | N/A | |||||||||
High-Speed Air Flow (735 Feet Per Seconds (ft/s)) | N/A | |||||||||
Note for Air Flow | N/A | |||||||||
Low-Speed Argon (Ar) Flow (164 Feet Per Seconds (ft/s)) | N/A | |||||||||
Standard Argon (Ar) Flow (304 Feet Per Seconds (ft/s)) | N/A | |||||||||
Maximum Argon (Ar) Flow (607 Feet Per Seconds (ft/s)) | N/A | |||||||||
High-Speed Argon (Ar) Flow (735 Feet Per Seconds (ft/s)) | N/A | |||||||||
Note for Argon (Ar) Flow | N/A | |||||||||
Low-Speed Carbon Dioxide (CO2) Flow (164 Feet Per Seconds (ft/s)) | N/A | |||||||||
Standard Carbon Dioxide (CO2) Flow (304 Feet Per Seconds (ft/s)) | N/A | |||||||||
Maximum Carbon Dioxide (CO2) Flow (607 Feet Per Seconds (ft/s)) | N/A | |||||||||
High-Speed Carbon Dioxide (CO2) Flow (735 Feet Per Seconds (ft/s) | N/A | |||||||||
Note for Carbon Dioxide (CO2) Flow | N/A | |||||||||
Low-Speed Nitrogen (N2) Flow (164 Feet Per Seconds (ft/s)) | N/A | |||||||||
Standard Nitrogen (N2) Flow (304 Feet Per Seconds (ft/s)) | N/A | |||||||||
Maximum Nitrogen (N2) Flow (607 Feet Per Seconds (ft/s)) | N/A | |||||||||
High-Speed Nitrogen (N2) Flow (735 Feet Per Seconds (ft/s)) | N/A | |||||||||
Note for Nitrogen (N2) Flow | N/A | |||||||||
Low-Speed Oxygen (O2) Flow (164 Feet Per Seconds (ft/s)) | N/A | |||||||||
Standard Oxygen (O2) Flow (304 Feet Per Seconds (ft/s)) | N/A | |||||||||
Maximum Oxygen (O2) Flow (607 Feet Per Seconds (ft/s)) | N/A | |||||||||
High-Speed Oxygen (O2) Flow (735 Feet Per Seconds (ft/s)) | N/A | |||||||||
Note for Oxygen (O2) Flow | N/A | |||||||||
Low-Speed Nitrous Oxide (N2O) Flow (164 Feet Per Seconds (ft/s)) | N/A | |||||||||
Standard Nitrous Oxide (N2O) Flow (304 Feet Per Seconds (ft/s)) | N/A | |||||||||
Maximum Nitrous Oxide (N2O) Flow (607 Feet Per Seconds (ft/s)) | N/A | |||||||||
High-Speed Nitrous Oxide (N2O) Flow (735 Feet Per Seconds (ft/s)) | N/A | |||||||||
Note for Nitrous Oxide (N2O) Flow | N/A | |||||||||
Low-Speed Natural Gas (NG) Flow (164 Feet Per Seconds (ft/s)) | N/A | |||||||||
Standard Natural Gas (NG) Flow (304 Feet Per Seconds (ft/s)) | N/A | |||||||||
Maximum Natural Gas (NG) Flow (607 Feet Per Seconds (ft/s)) | N/A | |||||||||
High-Speed Natural Gas (NG) Flow (735 Feet Per Seconds (ft/s)) | N/A | |||||||||
Note for Natural Gas (NG) Flow | N/A | |||||||||
Measuring Section | N/A | |||||||||
Flange Outer Pipe Diameter | N/A | |||||||||
Flange Inner Pipe Diameter | N/A | |||||||||
Dimension L (Flange) | N/A | |||||||||
Note for Dimension L (Flange) | N/A | |||||||||
Dimension L1 (Flange) | N/A | |||||||||
Dimension H (Flange) | N/A | |||||||||
Dimension H1 (Flange) | N/A | |||||||||
Diameter D (Flange) | N/A | |||||||||
Diameter K (Flange) | N/A | |||||||||
Number of Diameter L (Flange) | N/A | |||||||||
Diameter L (Flange) | N/A | |||||||||
Connection Thread | N/A | |||||||||
Thread Outer Pipe Diameter | N/A | |||||||||
Thread Inner Pipe Diameter | N/A | |||||||||
Dimension L (Thread) | N/A | |||||||||
Note for Dimension L (Thread) | N/A | |||||||||
Dimension L1 (Thread) | N/A | |||||||||
Dimension H (Thread) | N/A | |||||||||
Dimension H1 (Thread) | N/A | |||||||||
Dimension A (Thread) | N/A | |||||||||
Connection to Different Bus Systems Options | N/A | |||||||||
With a Key Stroke | N/A | |||||||||
Options | N/A | |||||||||
Application-Technological Features | N/A | |||||||||
Additional Information | N/A | |||||||||
|