Display shows 2 values at the same time:
  • Present flow in m³/h, CFM
  • Total consumption (counter reading) in CF
  • Temperature measurement
Readout values in the display can be rotated by 180º, e.g. for overhead installation.
Unit of Measure

Financing

Approve Payments

N/A Finance with Approve Payments

Specifications

Parameters

N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 ºC) in case of gases

Units Adjustable Via Keys at Display

N/A CFM ft/min g/s kg/h kg/min l/s lb/h lb/min m/s m³/h m³/min

Sensor

N/A Thermal Mass Flow Sensor

Measured Medium

N/A Air Gases

Gas Types are Adjustable Over CS Service Software or CS Data Logger

N/A Air Argon CO2 Nitrogen Oxygen

Accuracy

N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.)

Accuracy on Request

N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.)

Operating Temperature

N/A -22 to 176 ºF

Operating Temperature with Pressure Sensor

N/A -25 to 349 ºF

Operating Pressure

N/A -1 to 232 psi

Optional Pressure

N/A Up to Nominal Pressure (PN) 40

Digital Output

N/A M-Bus Modbus-Remote Terminal Unit (RTU) Optional: Ethernet Interface (PoE) RS 485 Interface

Analog Output for Cubic Feet Per Minute (CFM)

N/A 4 to 20 mA

Pulse Output

N/A 1 pulse per CF or per liter electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay.

Direct Current (DC) Supply Voltage

N/A 18 to 36 V

Power Supply

N/A 5 W

Burden

N/A <500 Ω

Housing Material

N/A Polycarbonate

Protection Rating

N/A Ingress Protection (IP 65)

Material

N/A Stainless Steel 1.4301

Mounting Position

N/A Any