VD 550 Robust Flow Sensors for Wet Compressed Air and Gases
Flow Differential Pressure
The integrated, precise differential pressure sensor measures the differential pressure/dynamic pressure at the sensor tip. The pressure depends on the respective gas velocity. The flow is therefore easy to determine by means of the pipe diameter.
The additional measurement of temperature and absolute pressure and calculation of the relevant density means that measuring can be carried out for various gases, a wide variety of temperatures and pressures.
The additional measurement of temperature and absolute pressure and calculation of the relevant density means that measuring can be carried out for various gases, a wide variety of temperatures and pressures.
Unit of Measure
Items |
![]() 0690 5501 VD 550 Robust Flow Sensor for Wet Compressed Air and Gases Web Price QUOTE
|
![]() 0553 0108 5 Meter (m) Length Connection Cable Web Price QUOTE
|
![]() 0553 0109 Connection Cable for 32.81 Feet (Ft) Length Probes with Open Ends Web Price QUOTE
|
![]() 0553 2503 16 Feet (ft) Length Ethernet Connection Cable Web Price QUOTE
|
![]() 0553 2504 32 Feet (ft) Length Ethernet Connection Cable Web Price QUOTE
|
|||||
Description |
N/A
The integrated, precise differential pressure sensor measures the differential pressure/dynamic pressure at the sensor tip. The pressure depends on the respective gas velocity. The flow is therefore easy to determine by means of the pipe diameter. The additional measurement of temperature and absolute pressure and calculation of the relevant density means that measuring can be carried out for various gases, a wide variety of temperatures and pressures. |
N/A Connection cable for probes 5 m, with open ends | N/A Connection cable for probes 32.81 ft with open ends | N/A Ethernet Connection Cable Length 16 Ft, M12 Plug X-coded (8 Pin) To Rj 45 Plug | N/A Ethernet connection cable length 32 ft, M12 plug x-coded (8 pin) to RJ 45 plug | |||||
Approve Payments |
N/A
Finance with Approve Payments |
|||||||||
Measuring Range (Compressed Air) | N/A 2 to 224 m/s600 m/s | N/A | N/A | N/A | N/A | |||||
Differential Pressure for Gases | N/A 0.04 to 500 mbar | N/A | N/A | N/A | N/A | |||||
Measured Medium | N/A Air Gas | N/A | N/A | N/A | N/A | |||||
Accuracy | N/A ± 1.5% of Measured Value (M.V.) | N/A | N/A | N/A | N/A | |||||
Measuring Principle | N/A Differential Pressure | N/A | N/A | N/A | N/A | |||||
Measuring Span | N/A 1:100 300 | N/A | N/A | N/A | N/A | |||||
Response Time | N/A t 99 <1 sec | N/A | N/A | N/A | N/A | |||||
Temperature of The Medium | N/A -22 to 356 ºF | N/A | N/A | N/A | N/A | |||||
Operating Pressure | N/A -1 to +100 barg | N/A | N/A | N/A | N/A | |||||
Ambient Temperature | N/A -4 to +158 ºF | N/A | N/A | N/A | N/A | |||||
Protection Class | N/A Ingress Protection (IP 67) | N/A | N/A | N/A | N/A | |||||
Direct Current (DC) Voltage | N/A 18 to 36 V | N/A | N/A | N/A | N/A | |||||
Power | N/A 5 W | N/A | N/A | N/A | N/A | |||||
Outputs | N/A 1x 4 to 20 mA analogue output (electrically not isolated), pulse output, RS 485 (Modbus-RTU) | N/A | N/A | N/A | N/A | |||||
Optional Output | N/A 2 x 4 to 20 mA active, Ethernet interface (PoE), M-Bus | N/A | N/A | N/A | N/A | |||||
Length | N/A | N/A 5 m | N/A | N/A 16 ft | N/A 32 ft | |||||
Voltage | N/A | |||||||||
Alternating Current (AC) Voltage | N/A | |||||||||
Frequency | N/A | |||||||||
Benefits |
N/A
Benefits at a glance:
|
N/A | N/A | N/A | N/A | |||||
Field of Application |
N/A
|
N/A | N/A | N/A | N/A | |||||
Typical Applications |
N/A
|
N/A | N/A | N/A | N/A | |||||
|