Flow Rate
|
|
12.55 scfm
|
|
Connection Size (NPT)
|
|
3/8 in
|
|
Dimension A
|
|
24.44 in
|
|
Dimension B
|
|
5.90 in
|
|
Dimension C
|
|
5.67 in
|
|
Dimension D
|
|
2.36 in
|
|
Integrated Pre-Filtration
|
|
0.01 µm
|
|
Alternating Current (AC) Voltage
|
|
115 to 230 V
|
|
Frequency
|
|
50 to 60 Hz
|
|
Minimum Ambient Temperature
|
|
34 ºF
|
|
Maximum Standard Operating Temperature
|
|
122 ºF
|
|
Maximum Standard Operating Pressure
|
|
145 psig
|
|
Maintenance Interval
|
|
8,000 hours
|
|
Inlet PDP (Pressure Dew Point)
|
|
+40 to +100 ºF
|
|
Outlet PDP (Pressure Dew Point) for Purge Air 10 %
|
|
+22 to +65 ºF
|
|
Outlet PDP (Pressure Dew Point) for Purge Air 17 %
|
|
0 to +35 ºF
|
|
Outlet PDP (Pressure Dew Point) for Purge Air 25 %
|
|
-30 to -4 ºF
|
|
Outlet PDP (Pressure Dew Point) for Purge Air 28 %
|
|
-40 to -20 ºF
|
|
Purge Air
|
|
10 % 17 % 25 % 28 %
|
|
Inlet Capacity for Purge Air 10 %
|
|
12.55 scfm
|
|
Weight
|
|
7.50 lb
|
|
Warranty
|
|