nano F1 performance validated compressed air & gas elements are designed to meet and exceed industry air quality requirements. Filtration performance is tested and validated by an independent laboratory to ISO 12500 standards.
Unit of Measure
Element Performance
M25 Part Number |
N/A E0135M25 |
Particle Removal (M25) |
N/A 25 µm |
Maximum Oil Carry Over at 68 Degree Fahrenheit (ºF) Temperature (M25) |
N/A 10 ppm |
Recommended Operating Temperature Range (M25) |
N/A 35 to 176 ºF |
Design Operating Temperature Range (M25) |
N/A 35 to 176 ºF |
M5 Part Number |
N/A E0135M5 |
Maximum Particle Size (International Organization for Standardization (ISO) Class) (M5) |
N/A 3 |
Maximum Oil Content (International Organization for Standardization (ISO) Class) (M5) |
N/A 4 |
Particle Removal (M5) |
N/A 5 µm |
Maximum Oil Carry Over at 68 Degree Fahrenheit (ºF) Temperature (M5) |
N/A 5 ppm |
Recommended Operating Temperature Range (M5) |
N/A 35 to 176 ºF |
Design Operating Temperature Range (M5) |
N/A 35 to 176 ºF |
M1 Part Number |
N/A E0135M1 |
Maximum Particle Size (International Organization for Standardization (ISO) Class) (M1) |
N/A 2 |
Maximum Oil Content (International Organization for Standardization (ISO) Class) (M1) |
N/A 2 |
Particle Removal (M1) |
N/A 1 µm |
Maximum Oil Carry Over at 68 Degree Fahrenheit (ºF) Temperature (M1) |
N/A 0.1 ppm |
Recommended Operating Temperature Range (M1) |
N/A 35 to 176 ºF |
Design Operating Temperature Range (M1) |
N/A 35 to 176 ºF |
M01 Part Number |
N/A E0135M01 |
Maximum Particle Size (International Organization for Standardization (ISO) Class) (M01) |
N/A 1 |
Maximum Oil Content (International Organization for Standardization (ISO) Class) (M01) |
N/A 2 |
Particle Removal (M01) |
N/A 0.01 µm |
Maximum Oil Carry Over at 68 Degree Fahrenheit (ºF) Temperature (M01) |
N/A 0.01 ppm |
Recommended Operating Temperature Range (M01) |
N/A 35 to 176 ºF |
Design Operating Temperature Range (M01) |
N/A 35 to 176 ºF |
AC Part Number |
N/A E0135AC |
Maximum Oil Content (International Organization for Standardization (ISO) Class) (AC) |
N/A 1 |
Maximum Oil Carry Over at 68 Degree Fahrenheit (ºF) Temperature (M01) (AC) |
N/A 0.003 ppm |
Recommended Operating Temperature Range (M01) (AC) |
N/A 35 to 77 ºF |
Design Operating Temperature Range (M01) (AC) |
N/A 35 to 122 ºF |