Model
|
|
HRC 720
|
|
|
Phase
|
|
3
|
|
|
Frequency
|
|
50 Hz 60 Hz
|
|
|
Air Flow at 50 Hertz (Hz) Frequency
|
|
247 ft³/min 420 m³/h
|
|
|
Air Flow at 60 Hertz (Hz) Frequency
|
|
294 ft³/min 500 m³/h
|
|
|
Rated Vacuum at 50 Hertz (Hz) Frequency
|
|
88 in. H2O 220 mbar
|
|
|
Rated Vacuum at 60 Hertz (Hz) Frequency
|
|
80 in. H2O 200 mbar
|
|
|
Rated Pressure at 50 Hertz (Hz) Frequency
|
|
80 in. H2O 200 mbar
|
|
|
Rated Pressure at 60 Hertz (Hz) Frequency
|
|
68 in. H2O 170 mbar
|
|
|
Motor Power at 50 Hertz (Hz) Frequency
|
|
4.0 hp 3.0 kW
|
|
|
Motor Power at 60 Hertz (Hz) Frequency
|
|
4.6 hp 3.4 kW
|
|
|
Voltage (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency
|
|
190 V
|
|
|
Voltage (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency
|
|
380 V
|
|
|
Voltage (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency
|
|
230 V
|
|
|
Voltage (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency
|
|
460 V
|
|
|
Current (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency
|
|
12.5 A
|
|
|
Current (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency
|
|
7.2 A
|
|
|
Current (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency
|
|
12.6 A
|
|
|
Current (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency
|
|
7.3 A
|
|
|
Sound Level at 50 Hertz (Hz) Frequency
|
|
70 dB
|
|
|
Sound Level at 60 Hertz (Hz) Frequency
|
|
73 dB
|
|
|
Weight
|
|
82 lb 37 kg
|
|