Model
|
|
HRC 300
|
|
|
Phase
|
|
3
|
|
|
Frequency
|
|
50 Hz 60 Hz
|
|
|
Air Flow at 50 Hertz (Hz) Frequency
|
|
124 ft³/min 210 m³/h
|
|
|
Air Flow at 60 Hertz (Hz) Frequency
|
|
150 ft³/min 255 m³/h
|
|
|
Rated Vacuum at 50 Hertz (Hz) Frequency
|
|
80 in. H2O 200 mbar
|
|
|
Rated Vacuum at 60 Hertz (Hz) Frequency
|
|
88 in. H2O 220 mbar
|
|
|
Rated Pressure at 50 Hertz (Hz) Frequency
|
|
76 in. H2O 190 mbar
|
|
|
Rated Pressure at 60 Hertz (Hz) Frequency
|
|
79 in. H2O 197 mbar
|
|
|
Motor Power at 50 Hertz (Hz) Frequency
|
|
2.1 hp 1.6 kW
|
|
|
Motor Power at 60 Hertz (Hz) Frequency
|
|
2.8 hp 2.0 kW
|
|
|
Voltage (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency
|
|
190 V
|
|
|
Voltage (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency
|
|
380 V
|
|
|
Voltage (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency
|
|
230 V
|
|
|
Voltage (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency
|
|
460 V
|
|
|
Current (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency
|
|
7.5 A
|
|
|
Current (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency
|
|
4.3 A
|
|
|
Current (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency
|
|
7.3 A
|
|
|
Current (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency
|
|
4.4 A
|
|
|
Sound Level at 50 Hertz (Hz) Frequency
|
|
64 dB
|
|
|
Sound Level at 60 Hertz (Hz) Frequency
|
|
70 dB
|
|
|
Weight
|
|
51 lb 23 kg
|
|