Brands
|
|
nano
|
|
|
Maximum Oxygen Content for 99.999 Percent (%) Nitrogen Purity
|
|
10 ppm
|
|
|
Rated Outlet Flow at 99.999 Percent (%) Nitrogen Purity
|
|
28 scfh
|
|
|
Maximum Oxygen Content for 99.995 Percent (%) Nitrogen Purity
|
|
50 ppm
|
|
|
Rated Outlet Flow at 99.995 Percent (%) Nitrogen Purity
|
|
49 scfh
|
|
|
Maximum Oxygen Content for 99.99 Percent (%) Nitrogen Purity
|
|
100 ppm
|
|
|
Rated Outlet Flow at 99.99 Percent (%) Nitrogen Purity
|
|
60 scfh
|
|
|
Maximum Oxygen Content for 99.95 Percent (%) Nitrogen Purity
|
|
500 ppm
|
|
|
Rated Outlet Flow at 99.95 Percent (%) Nitrogen Purity
|
|
95 scfh
|
|
|
Maximum Oxygen Content for 99.9 Percent (%) Nitrogen Purity
|
|
0.10 %
|
|
|
Rated Outlet Flow at 99.9 Percent (%) Nitrogen Purity
|
|
113 scfh
|
|
|
Maximum Oxygen Content for 99.5 Percent (%) Nitrogen Purity
|
|
0.50 %
|
|
|
Rated Outlet Flow at 99.5 Percent (%) Nitrogen Purity
|
|
184 scfh
|
|
|
Maximum Oxygen Content for 99 Percent (%) Nitrogen Purity
|
|
1 %
|
|
|
Rated Outlet Flow at 99 Percent (%) Nitrogen Purity
|
|
226 scfh
|
|
|
Maximum Oxygen Content for 98 Percent (%) Nitrogen Purity
|
|
2 %
|
|
|
Rated Outlet Flow at 98 Percent (%) Nitrogen Purity
|
|
276 scfh
|
|
|
Maximum Oxygen Content for 97 Percent (%) Nitrogen Purity
|
|
3 %
|
|
|
Rated Outlet Flow at 97 Percent (%) Nitrogen Purity
|
|
311 scfh
|
|
|
Maximum Oxygen Content for 95 Percent (%) Nitrogen Purity
|
|
5 %
|
|
|
Rated Outlet Flow at 95 Percent (%) Nitrogen Purity
|
|
392 scfh
|
|
|
Note for Rated Outlet Flow
|
|
At 101.5 psig and 77ºF inlet conditions. Contact nano for flow, pressure and purity outside listed range.
|
|
|
Dimension A
|
|
49 in
|
|
|
Dimension B
|
|
17 in
|
|
|
Dimension C
|
|
18 in
|
|
|
Approximate Weight
|
|
183 lb
|
|
|
Recommended Inlet Air Quality (International Organization for Standardization (ISO) Class)
|
|
2.2.1
|
|
|
Minimum Inlet Air Quality (International Organization for Standardization (ISO) Class)
|
|
2.4.1
|
|
|
Minimum Operating Pressure
|
|
87 psig
|
|
|
Maximum Operating Pressure
|
|
145 psig
|
|
|
Recommended Operating Temperature Range
|
|
68 to 77 ºF
|
|
|
Minimum Operating Temperature Range
|
|
41 ºF
|
|
|
Maximum Operating Temperature Range
|
|
122 ºF
|
|
|
Alternating Current (AC) Supply Voltage
|
|
100 to 240 V
|
|
|
Fuse Rating
|
|
3A 'T'
|
|
|
Frequency
|
|
50 to 60 Hz
|
|
|
Maximum Power Consumption
|
|
72 W
|
|
|
Ingress Protection (IP) Rating
|
|
Ingress Protection Rating (IP53) (National Electrical Manufacturers Association (NEMA) 2)
|
|