All Categories > Nitrogen Generators > Nano > nano GEN2MINI On-Site Nitrogen Gas Generators > Item # GEN2MINI-100  


Item # GEN2MINI-100, 43 Inch (in) Dimension A nano GEN2MINI On-Site Nitrogen Gas Generator

Web Price QUOTE

  • Ultra compact design and wide range of flow rates, make it the perfect generator for a variety of lower flow nitrogen applications.
  • Significant cost savings over cylinder or liquid supply provides a typical return on investment of less than 24 months.
  • Uses pressure swing adsorption to produce a continuous, uninterrupted supply of 95 to 99.999% purity nitrogen gas from clean, dry compressed air.
  • 100% functional tested with 2 year warranty.
  • Eliminates safety concerns associated with transporting and storing pressurized gas cylinders or liquid nitrogen.
  • Reduces carbon footprint by eliminating gas delivery with positive impacts on sustainability targets.






Financing  · Specifications  · Pressure Correction Factors  · Temperature Correction Factors  · Features  · Note for Pressure and Temperature Correction Factors

Financing

Approve Payments

Finance with Approve Payments



Specifications

Brands

nano

Maximum Oxygen Content for 99.999 Percent (%) Nitrogen Purity

10 ppm

Rated Outlet Flow at 99.999 Percent (%) Nitrogen Purity

18 scfh

Maximum Oxygen Content for 99.995 Percent (%) Nitrogen Purity

50 ppm

Rated Outlet Flow at 99.995 Percent (%) Nitrogen Purity

46 scfh

Maximum Oxygen Content for 99.99 Percent (%) Nitrogen Purity

100 ppm

Rated Outlet Flow at 99.99 Percent (%) Nitrogen Purity

53 scfh

Maximum Oxygen Content for 99.95 Percent (%) Nitrogen Purity

500 ppm

Rated Outlet Flow at 99.95 Percent (%) Nitrogen Purity

78 scfh

Maximum Oxygen Content for 99.9 Percent (%) Nitrogen Purity

0.10 %

Rated Outlet Flow at 99.9 Percent (%) Nitrogen Purity

88 scfh

Maximum Oxygen Content for 99.5 Percent (%) Nitrogen Purity

0.50 %

Rated Outlet Flow at 99.5 Percent (%) Nitrogen Purity

148 scfh

Maximum Oxygen Content for 99 Percent (%) Nitrogen Purity

1 %

Rated Outlet Flow at 99 Percent (%) Nitrogen Purity

187 scfh

Maximum Oxygen Content for 98 Percent (%) Nitrogen Purity

2 %

Rated Outlet Flow at 98 Percent (%) Nitrogen Purity

240 scfh

Maximum Oxygen Content for 97 Percent (%) Nitrogen Purity

3 %

Rated Outlet Flow at 97 Percent (%) Nitrogen Purity

276 scfh

Maximum Oxygen Content for 95 Percent (%) Nitrogen Purity

5 %

Rated Outlet Flow at 95 Percent (%) Nitrogen Purity

339 scfh

Note for Rated Outlet Flow

At 101.5 psig and 77ºF inlet conditions. Contact nano for flow, pressure and purity outside listed range.

Dimension A

43 in

Dimension B

17 in

Dimension C

18 in

Approximate Weight

168 lb

Recommended Inlet Air Quality (International Organization for Standardization (ISO) Class)

2.2.1

Minimum Inlet Air Quality (International Organization for Standardization (ISO) Class)

2.4.1

Minimum Operating Pressure

87 psig

Maximum Operating Pressure

145 psig

Recommended Operating Temperature Range

68 to 77 ºF

Minimum Operating Temperature Range

41 ºF

Maximum Operating Temperature Range

122 ºF

Alternating Current (AC) Supply Voltage

100 to 240 V

Fuse Rating

3A 'T'

Frequency

50 to 60 Hz

Maximum Power Consumption

72 W

Ingress Protection (IP) Rating

Ingress Protection Rating (IP53) (National Electrical Manufacturers Association (NEMA) 2)


Pressure Correction Factors

Pressure Correction Factors at 87.0 Pounds per Square Inch Gauge (psig) Inlet Pressure

0.88

Pressure Correction Factors at 101.5 Pounds per Square Inch Gauge (psig) Inlet Pressure

1.00

Pressure Correction Factors at 116.0 Pounds per Square Inch Gauge (psig) Inlet Pressure

1.10

Pressure Correction Factors at 130.5 Pounds per Square Inch Gauge (psig) Inlet Pressure

1.20

Pressure Correction Factors at 145.0 Pounds Per Square Inch Gauge (psig) Inlet Pressure

1.30


Temperature Correction Factors

Temperature Correction Factors at 41 Degree Fahrenheit (ºF) Inlet Temperature

0.80

Temperature Correction Factors at 50 Degree Fahrenheit (ºF) Inlet Temperature

0.90

Temperature Correction Factors at 59 Degree Fahrenheit (ºF) Inlet Temperature

0.94

Temperature Correction Factors at 68 Degree Fahrenheit (ºF) Inlet Temperature

1.00

Temperature Correction Factors at 77 Degree Fahrenheit (ºF) Inlet Temperature

1.00

Temperature Correction Factors at 86 Degree Fahrenheit (ºF) Inlet Temperature

0.98

Temperature Correction Factors at 95 Degree Fahrenheit (ºF) Inlet Temperature

0.95

Temperature Correction Factors at 104 Degree Fahrenheit (ºF) Inlet Temperature

0.90

Temperature Correction Factors at 113 Degree Fahrenheit (ºF) Inlet Temperature

0.85

Temperature Correction Factors at 122 Degree Fahrenheit (ºF) Inlet Temperature

0.72


Features
  • Eco-mode energy savings control reduces energy consumption during periods of low demand.
  • Optional integrated O2 analyzer and dew point sensors (N2 or inlet air).




Note for Pressure and Temperature Correction Factors
To be used as rough guide only. All applications should be confirmed by nano.