Brands
|
|
nano
|
|
|
Maximum Oxygen Content for 99.999 Percent (%) Nitrogen Purity
|
|
10 ppm
|
|
|
Rated Outlet Flow at 99.999 Percent (%) Nitrogen Purity
|
|
3960 scfh
|
|
|
Maximum Oxygen Content for 99.99 Percent (%) Nitrogen Purity
|
|
100 ppm
|
|
|
Rated Outlet Flow at 99.99 Percent (%) Nitrogen Purity
|
|
6120 scfh
|
|
|
Maximum Oxygen Content for 99.95 Percent (%) Nitrogen Purity
|
|
500 ppm
|
|
|
Rated Outlet Flow at 99.95 Percent (%) Nitrogen Purity
|
|
8040 scfh
|
|
|
Maximum Oxygen Content for 99.9 Percent (%) Nitrogen Purity
|
|
0.10 %
|
|
|
Rated Outlet Flow at 99.9 Percent (%) Nitrogen Purity
|
|
10500 scfh
|
|
|
Maximum Oxygen Content for 99.5 Percent (%) Nitrogen Purity
|
|
0.50 %
|
|
|
Rated Outlet Flow at 99.5 Percent (%) Nitrogen Purity
|
|
14700 scfh
|
|
|
Maximum Oxygen Content for 99 Percent (%) Nitrogen Purity
|
|
1 %
|
|
|
Rated Outlet Flow at 99 Percent (%) Nitrogen Purity
|
|
17400 scfh
|
|
|
Maximum Oxygen Content for 98 Percent (%) Nitrogen Purity
|
|
2 %
|
|
|
Rated Outlet Flow at 98 Percent (%) Nitrogen Purity
|
|
21240 scfh
|
|
|
Maximum Oxygen Content for 97 Percent (%) Nitrogen Purity
|
|
3 %
|
|
|
Rated Outlet Flow at 97 Percent (%) Nitrogen Purity
|
|
24540 scfh
|
|
|
Maximum Oxygen Content for 96 Percent (%) Nitrogen Purity
|
|
4 %
|
|
|
Rated Outlet Flow at 96 Percent (%) Nitrogen Purity
|
|
27360 scfh
|
|
|
Maximum Oxygen Content for 95 Percent (%) Nitrogen Purity
|
|
5 %
|
|
|
Rated Outlet Flow at 95 Percent (%) Nitrogen Purity
|
|
30240 scfh
|
|
|
Note for Rated Outlet Flow
|
|
At 100 psig inlet pressure and 68 to 77ºF inlet temperature.
|
|
|
Dimension A
|
|
105 in
|
|
|
Dimension B
|
|
71 in
|
|
|
Dimension C
|
|
104 in
|
|
|
Approximate Weight
|
|
10582 lb
|
|
|
Design Operating Pressure Range
|
|
72.5 to 145 psig
|
|
|
Design Operating Temperature Range
|
|
41 to 122 ºF
|
|
|
Recommended Operating Temperature Range
|
|
41 to 95 ºF
|
|
|
Maximum Inlet Particulate
|
|
0.1 µ
|
|
|
Maximum Temperature at Inlet Pressure Dew Point (PDP)
|
|
45 ºF
|
|
|
Recommended Inlet Pressure Dew Point (PDP)
|
|
± 37.4
|
|
|
Note for Recommended Maximum Inlet Pressure Dew Point (PDP)
|
|
PDP must always be lower than ambient temperature.
|
|
|
Maximum Inlet Oil Content
|
|
0.01 ppm
|
|
|
Note for Maximum Inlet Oil Content
|
|
Including oil vapor
|
|
|
Alternating Current (AC) Supply Voltage
|
|
100 to 240 V
|
|
|
Frequency
|
|
50 to 60 Hz
|
|
|
Warranty
|
|