Inlet Air Pressure |
N/A 100 psi125 psi150 psi200 psi |
Dimension A at 100 psi Inlet Air Pressure |
N/A 40 in |
Dimension A at 125 psi Inlet Air Pressure |
N/A 40 in |
Dimension A at 150 psi Inlet Air Pressure |
N/A 40 in |
Dimension A at 200 psi Inlet Air Pressure |
N/A 40 in |
Dimension B at 100 psi Inlet Air Pressure |
N/A 48 in |
Dimension B at 125 psi Inlet Air Pressure |
N/A 48 in |
Dimension B at 150 psi Inlet Air Pressure |
N/A 48 in |
Dimension B at 200 psi Inlet Air Pressure |
N/A 48 in |
Dimension C at 100 psi Inlet Air Pressure |
N/A 5.5 in |
Dimension C at 125 psi Inlet Air Pressure |
N/A 5.5 in |
Dimension C at 150 psi Inlet Air Pressure |
N/A 5.5 in |
Dimension C at 200 psi Inlet Air Pressure |
N/A 5.5 in |
Approximate Weight at 100 psi Inlet Air Pressure |
N/A 51 lb |
Approximate Weight at 125 psi Inlet Air Pressure |
N/A 51 lb |
Approximate Weight at 150 psi Inlet Air Pressure |
N/A 51 lb |
Approximate Weight at 200 psi Inlet Air Pressure |
N/A 51 lb |
Inlet and Outlet Connection Size |
N/A 1/2 in |
Connection Type |
N/A National Pipe Thread (NPT) |
Design Operating Pressure Range |
N/A 100 to 200 psi |
Design Operating Temperature Range |
N/A 41 to 113 ºF |
Pressure Drop |
N/A 7 to 10 psi |
Rated Outlet Flow at 99.9% (0.1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 100 psi Inlet Air Pressure |
N/A 63 scfh |
Rated Outlet Flow at 99.9% (0.1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 125 psi Inlet Air Pressure |
N/A 87 scfh |
Rated Outlet Flow at 99.9% (0.1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 150 psi Inlet Air Pressure |
N/A 100 scfh |
Rated Outlet Flow at 99.9% (0.1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 200 psi Inlet Air Pressure |
N/A 145 scfh |
Rated Outlet Flow at 99.5% (0.5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 100 psi Inlet Air Pressure |
N/A 126 scfh |
Rated Outlet Flow at 99.5% (0.5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 125 psi Inlet Air Pressure |
N/A 174 scfh |
Rated Outlet Flow at 99.5% (0.5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 150 psi Inlet Air Pressure |
N/A 200 scfh |
Rated Outlet Flow at 99.5% (0.5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 200 psi Inlet Air Pressure |
N/A 290 scfh |
Rated Outlet Flow at 99% (1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 100 psi Inlet Air Pressure |
N/A 168 scfh |
Rated Outlet Flow at 99% (1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 125 psi Inlet Air Pressure |
N/A 232 scfh |
Rated Outlet Flow at 99% (1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 150 psi Inlet Air Pressure |
N/A 268 scfh |
Rated Outlet Flow at 99% (1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 200 psi Inlet Air Pressure |
N/A 388 scfh |
Rated Outlet Flow at 98% (2%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 100 psi Inlet Air Pressure |
N/A 260 scfh |
Rated Outlet Flow at 98% (2%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 125 psi Inlet Air Pressure |
N/A 352 scfh |
Rated Outlet Flow at 98% (2%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 150 psi Inlet Air Pressure |
N/A 394 scfh |
Rated Outlet Flow at 98% (2%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 200 psi Inlet Air Pressure |
N/A 586 scfh |
Rated Outlet Flow at 97% (3%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 100 psi Inlet Air Pressure |
N/A 330 scfh |
Rated Outlet Flow at 97% (3%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 125 psi Inlet Air Pressure |
N/A 452 scfh |
Rated Outlet Flow at 97% (3%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 150 psi Inlet Air Pressure |
N/A 514 scfh |
Rated Outlet Flow at 97% (3%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 200 psi Inlet Air Pressure |
N/A 776 scfh |
Rated Outlet Flow at 96% (4%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 100 psi Inlet Air Pressure |
N/A 408 scfh |
Rated Outlet Flow at 96% (4%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 125 psi Inlet Air Pressure |
N/A 556 scfh |
Rated Outlet Flow at 96% (4%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 150 psi Inlet Air Pressure |
N/A 628 scfh |
Rated Outlet Flow at 96% (4%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 200 psi Inlet Air Pressure |
N/A 918 scfh |
Rated Outlet Flow at 95% (5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 100 psi Inlet Air Pressure |
N/A 486 scfh |
Rated Outlet Flow at 95% (5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 125 psi Inlet Air Pressure |
N/A 656 scfh |
Rated Outlet Flow at 95% (5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 150 psi Inlet Air Pressure |
N/A 776 scfh |
Rated Outlet Flow at 95% (5%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) and 200 psi Inlet Air Pressure |
N/A 1058 scfh |
Inlet Air to Outlet Nitrogen Ratio at 99.9% Nitrogen Purity |
N/A 7.5 |
Inlet Air to Outlet Nitrogen Ratio at 99.5% Nitrogen Purity |
N/A 4.7 |
Inlet Air to Outlet Nitrogen Ratio at 99% Nitrogen Purity |
N/A 3.8 |
Inlet Air to Outlet Nitrogen Ratio at 98% Nitrogen Purity |
N/A 2.9 |
Inlet Air to Outlet Nitrogen Ratio at 97% Nitrogen Purity |
N/A 2.5 |
Inlet Air to Outlet Nitrogen Ratio at 96% Nitrogen Purity |
N/A 2.3 |
Inlet Air to Outlet Nitrogen Ratio at 95% Nitrogen Purity |
N/A 2.1 |
N/A
A few of the many industries making the switch to nano N-Series Nitrogen generators include:
|
Guaranteed Performance |
N/A
|
Rapid Return on Investment |
N/A
|
Environmentally Friendly |
N/A
|
Safe and Reliable |
N/A
|
Easy to Install |
N/A
|
Easy to Maintain |
N/A
|
Fits any Application |
N/A Air from your plant compressed air system enters the system through the inlet ports (A). It then passes through a nano NWS centrifugal water separator to remove any bulk condensate (B). Collected condensate is expelled from the system using a nano NMD magnetic zero air loss drain (C). The air then passes through three nano NF filters in series: an M1 1.0 micron coalescing filter (D), an M01 0.01 micron coalescing filter (E), and an AC activated carbon filter (F). This removes remaining liquid aerosols, solid particulate and oil vapor. The air then passes through one or more membrane Nitrogen generators (G). The generator contains hundreds of thousands of hollow fibers which separate the Nitrogen from the air through a process known as selective permeation. The walls of these fibers allow Oxygen and water vapor molecules to pass through but not Nitrogen. A simple manual valve (H) controls the flow and thereby the purity of the Nitrogen. Clean, pure, dry Nitrogen then flows out of the outlet port to your downstream process. |
N/A Air from your plant compressed air system enters the system through the inlet ports (A). It then passes through a nano NWS centrifugal water separator to remove any bulk condensate (B). Collected condensate is expelled from the system using a nano NMD magnetic zero air loss drain (C). The air then passes through three nano NF filters in series: an M1 1.0 micron coalescing filter (D), an M01 0.01 micron coalescing filter (E), and an AC activated carbon filter (F). This removes remaining liquid aerosols, solid particulate and oil vapor. The air then passes through one or more membrane Nitrogen generators (G). The generator contains hundreds of thousands of hollow fibers which separate the Nitrogen from the air through a process known as selective permeation. The walls of these fibers allow Oxygen and water vapor molecules to pass through but not Nitrogen. A simple manual valve (H) controls the flow and thereby the purity of the Nitrogen. Clean, pure, dry Nitrogen then flows out of the outlet port to your downstream process. |