Degree of Filtration
|
|
KA (Activated Carbon Filter Adsorption) KB (Coalescence Filter Basic) KBE (Extra Combination) KD (Particulate Filter Dust) KE (Coalescence Filter Extra) KEA (Carbon Combinator)
|
|
Initial Differential Pressure with Saturation (KB Degree of Filtration)
|
|
< 2 2 psi
|
|
Initial Differential Pressure with Saturation (KE Degree of Filtration)
|
|
< 3.0 psi
|
|
Initial Differential Pressure with Saturation (KD Degree of Filtration)
|
|
< 0.8 (New, Dry) psi
|
|
Initial Differential Pressure with Saturation (KA Degree of Filtration)
|
|
0.8 (New, Dry) psi
|
|
Initial Differential Pressure with Saturation (KBE Degree of Filtration)
|
|
< 5.2 psi
|
|
Initial Differential Pressure with Saturation (KEA Degree of Filtration)
|
|
< 3.8 psi
|
|
Aerosol Content at Inlet (KB Degree of Filtration)
|
|
10 mg/m³
|
|
Aerosol Content at Inlet (KE Degree of Filtration)
|
|
10 mg/m³
|
|
Aerosol Content at Inlet (KBE Degree of Filtration)
|
|
10 mg/m³
|
|
Aerosol Content at Inlet (KEA Degree of Filtration)
|
|
10 mg/m³
|
|
Residual Aerosol Content at Outst According to ISO 12500-1 (KB Degree of Filtration)
|
|
< 0 01 mg/m³
|
|
Residual Aerosol Content at Outst According to ISO 12500-1 (KE Degree of Filtration)
|
|
< 0 01 mg/m³
|
|
Residual Aerosol Content at Outst According to ISO 12500-1 (KBADegree of Filtration)
|
|
< 0 01 mg/m³
|
|
Residual Aerosol Content at Outst According to ISO 12500-1 (KEA Degree of Filtration)
|
|
0.003 mg/m³ (Total Oil Content)
|
|
Filter Medium (KB Degree of Filtration)
|
|
Deep-pleated with support structure and polyester drainage fiber
|
|
Filter Medium (KE Degree of Filtration)
|
|
Deep-pleated with support structure and polyester drainage fiber
|
|
Filter Medium (KD Degree of Filtration)
|
|
Deeply pleated with supporting structure
|
|
Filter Medium (KA Degree of Filtration)
|
|
High-efficiency carbon fleece
|
|
Application (KB Degree of Filtration)
|
|
Filtration of solid and liquid aerosols and solid particles
|
|
Application (KE Degree of Filtration)
|
|
Same application as KB, but for higher compressed air quality; alternatively: micro-particle filter to KD degree of filtration
|
|
Application (KD Degree of Filtration)
|
|
Exclusively for the filtration of solid particles
|
|
Application (KA Degree of Filtration)
|
|
Exclusively for the removal of oil vapors
|
|
Application (KBE Degree of Filtration)
|
|
Combination of KB and KE; application as KE, but for higher assurance of compressed air quality
|
|
Application (KEA Degree of Filtration)
|
|
Combination of KE and KA, filtration of aerosols, solid matter particles and oil vapors
|
|