Measuring Range
|
|
Up to 164 ft/s, Low-Speed Version Up to 304 ft/s, Standard Version Up to 607 ft/s, Maximum Version Up to 735 ft/s, High-Speed Version
|
|
Note for Measuring Range
|
|
All measured values related to DIN 1343 standard conditions 32 ºF and 14.7 psi ex works.
|
|
Accuracy
|
|
± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.)
|
|
Accuracy on Request
|
|
± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.)
|
|
Accuracy Indications
|
|
Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 6 bar
|
|
Repeatability
|
|
0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section)
|
|
Measuring Principle
|
|
Thermal Mass Flow Sensor
|
|
Response Time
|
|
t 90 <3 sec
|
|
Operating/Ambient Temperature Range
|
|
-4 to 158 ºF
|
|
Media Temperature Range
|
|
-4 to 356 ºF
|
|
Media Temperature Range (ATEX Version)
|
|
-4 to 248 ºF
|
|
Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis
|
|
Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc.
|
|
Standard Outputs
|
|
1 x 4 to 20 mA Analog Output (Electrically Not Isolated) Pulse Output RS 485 (Modbus-RTU)
|
|
Optional Outputs
|
|
2 x 4 to 20 mA Active HART M-Bus Mod- bus TCP Profibus DP Profinet
|
|
Burden
|
|
<500 Ω
|
|
Additional Average Value Calculation
|
|
For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value
|
|
Protection Class
|
|
Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90°C Db Ingress Protection (IP 67)
|
|
Housing Material
|
|
Die-Cast Aluminum
|
|
Sensor Tube Material
|
|
Stainless Steel 1.4404
|
|
Operating Pressure
|
|
232 psi
|
|
Special Version Operating Pressure
|
|
580 psi
|
|
Direct Current (DC) Supply Voltage
|
|
18 to 36 V
|
|
Power Supply
|
|
5 W
|
|
Approval
|
|
ATEX II 2G Ex db IIC T4 Gb ATEX II 2D Ex tb IIIC T90 ºC Db DVGW
|
|
|
|
|
|
|
|
|
There are different options available for connection to modern Bus systems:- Ethernet interface (Modbus-TCP) / PoE
- M-BUS
- Modbus-RTU
- Profibus DP interface (in process)
- Profinet interface (in process)
- HART (in process)
|
|
|
|
- 4 values on the display: Flow, total consumption, velocity, temperature. Units freely adjustable
- All measured values, settings such as gas type, inner diameter, serial number and so on can be accessed via Modbus-RTU
- Comprehensive diagnostic functions readable on the display or remote access via Modbus such as calibration cycle, error codes, serial number
- Notification in case of exceeding the calibration cycle
- Standard version accuracy 1.5% of m.v. ± 0.3% of f.s.
- Precision version accuracy 1.0% of m.v. ± 0.3% of f.s
- Measuring span of 1 : 1000 (0.33 ft/s up to 735 ft/s)
- Configuration and diagnosis via display, hand-held device PI 500, PC service software on-site
- Gas type (air, nitrogen, oxygen, argon and so on) freely adjustable via PC service software or external device DS 400, DS 500, PI 500
- Reference conditions ºC and PST / hPA freely adjustable
- In-Situ adjustment, leak flow volume suppression
- Pressure loss negligible
|
|
|
|
- Robust impact-proof aluminum die cast housing for the outdoor area IP 67
- All wetted parts made from stainless steel 1.4404
- On request with DVGW approval for natural gas (up to 232 psi)
- Pressure range up to 232 psi, special version up to 580 psi
- Media temperature range up to 356 ºF (ATEX version up to 248 ºF)
- No moveable parts, no wear
- Sensor tip very robust, easy to clean
- Housing rotatable, display rotatable by -356 ºF
|
|
|
|
The screwing with a centring device is designed such that the sensor is positioned accurately in the center when screwing it into the measuring section; furthermore, it enables an exact positioning in the flow direction. This eliminates unnecessary measuring faults.
|
|
|
|