Print Back
Unit of Measure

Financing

Approve Payments

N/A Finance with Approve Payments

Specifications

Dimension a

N/A 8.82 in

Dimension b

N/A 6.26 in

Dimension c

N/A 6.18 in

Dimension d

N/A 1.50 in

Dimension l

N/A 3.07 in

Dimension r

N/A 2.91 in

Diameter s

N/A 0.47 in

Dimension R

N/A 3/8 in

Connection Type

N/A British Standard Pipe (BSP)

Air Flow at 50 Hz

N/A 3.5 cfm

Air Flow at 60 Hz

N/A 4.2 cfm

Excess Pressure (3 ~) at 50 Hz

N/A 14.5 psi

Excess Pressure (3 ~) at 60 Hz

N/A 5.8 psi14.5 psi

Motor Version (3 ~) Voltage at 50 Hz

N/A 200 to 255 V346 to 440 V

Motor Version (3 ~) Voltage at 60 Hz

N/A 230 V460 V

Motor Version (3 ~) Tolerance at 60 Hz

N/A ±10 %

Motor Version (1 ~) Voltage at 50 Hz

N/A 230 V

Motor Version (1 ~) Tolerance at 50 Hz

N/A ±10 %

Motor Version (1 ~) Voltage at 60 Hz

N/A 115 V

Motor Version (1 ~) Tolerance at 60 Hz

N/A ±10 %

Motor Rating (3 ~) at 50 Hz

N/A 0.25 kW

Motor Rating (3 ~) at 60 Hz

N/A 0.30 kW

Motor Rating (1 ~) at 14.5 Excess Pressure (1 ~) at 50 Hz

N/A 0.25 kW

Motor Rating (1 ~) at 5.8 Excess Pressure (1 ~) at 50 Hz

N/A 0.120 kW

Motor Rating (1 ~) at 14.5 Excess Pressure (1 ~) at 60 Hz

N/A 0.30 kW

Motor Rating (1 ~) at 5.8 Excess Pressure (1 ~) at 60 Hz

N/A 0.145 kW

Full Load Amperage (3 ~) at 50 Hz

N/A 0.81 kW1.40 kW

Full Load Amperage (3 ~) at 60 Hz

N/A 0.85 kW1.70 kW

Full Load Amperage (1 ~) at 14.5 Excess Pressure (1 ~) at 50 Hz

N/A 2.3 kW

Full Load Amperage (1 ~) at 5.8 Excess Pressure (1 ~) at 50 Hz

N/A 1.3 kW

Average Noise Level at 14.5 psi Excess Pressure (1 ~)

N/A 16.5 lb

Speed at 50 Hz

N/A 2750 rpm

Speed at 60 Hz

N/A 3300 rpm

Average Noise Level at 14.5 psi Excess Pressure (1 ~) at 50 Hz

N/A 60 dBA

Average Noise Level at 14.5 psi Excess Pressure (1 ~) at 60 Hz

N/A 61 dBA

Pressure Regulating Valve (ZRD)

N/A 6

Non Return Valve (ZRK)

N/A 12 (03)

Note

Note

N/A Capacity refers to free air at 1 standard atmosphere and 20 ºC (68 ºF).
Curves and tables refer to compressor at normal operating temperature.
Technical information is subject to change without notice!
For ZMS - on request