Measuring Range (Atmospheric Pressure)
|
|
-112 to 68 ºF -4 to 112 ºF
|
|
Accuracy (±) at 122 to -4 Degree Fahrenheit (ºF) Temperature
|
|
1.8 ºF
|
|
Accuracy (±) at -4 to -58 Degree Fahrenheit (ºF) Temperature (Atmospheric Pressure)
|
|
3.6 ºF
|
|
Accuracy (±) at -58 to -112 Degree Fahrenheit (ºF) Temperature (Atmospheric Pressure)
|
|
5.4 ºF
|
|
Pressure Range
|
|
-14 to 725 psi
|
|
Pressure Range (Special Version)
|
|
Up to 7252 psi
|
|
Direct Current (DC) Voltage
|
|
10 to 36 V 24 V
|
|
Protection Class
|
|
IP 66
|
|
Electromagnetic Compatibility (EMC)
|
|
In According with DIN EN 61326-1
|
|
Operating Temperature
|
|
-4 to 158 ºF
|
|
Connection
|
|
M12
|
|
Number of Connection Pins
|
|
5
|
|
Personal Computer (PC) Connection
|
|
Modbus-RTU interface (RS 485)
|
|
Analog Output
|
|
4 to 20 mA = -112 to 68 ºFtd 4 to 20 mA = -4 to 122 ºFtd FA 510: 4 to 20 mA (3-wire) FA 515: 4 to 20 mA (2-wire)
|
|
Burden for Analog Output
|
|
500 Ω
|
|
Screw-In Thread
|
|
G 1/2 in. Stainless Steel
|
|
Optional Screw-In Thread
|
|
1/2 in. National Pipe Thread (NPT) 5/8 in. Unified National Fine (UNF)
|
|
Via Service Software (Choose Units)
|
|
% RH lb/CF mg/CF ºFtd ppm V/V
|
|
Scaling Current Change
|
|
4 to 20 mA
|
|