Dimension A |
N/A 32 in |
Dimension B |
N/A 83 in |
Dimension C |
N/A 77 in |
Optional Inlet (X2) |
N/A 1 |
Outlet Size |
N/A 1 in |
Power |
N/A 5 hp |
Type |
N/A Triplex |
Air Flow at 145 psig |
N/A 37.5 scfm |
Tank Capacity |
N/A 120 gal |
Air Flow |
N/A 36600 Btu/hr |
Sound Level |
N/A 76 dBA |
Warranty (Limited) |
N/A 3 years |
System Full Load Current (F.L.A) at 208 V |
N/A 50.1 A |
System Full Load Current (F.L.A) at 230 V |
N/A 45.6 A |
System Full Load Current (F.L.A) at 460 V |
N/A 22.8 A |
System Weight |
N/A 1,850 lb |
Electrical Panel Opening |
N/A 42 in |
Minimum Clearance for Ease of Maintenance |
N/A 24 in |
Brands |
N/A Powerex® |
N/A
Each compressor shall be belt driven oil-less rotary scroll single stage, air-cooled construction with absolutely no oil needed for operation. Direct drive compressors shall not be used.
|
N/A Each compressor shall be belt driven by a 1750 RPM, ODP, NEMA construction motor. Motors running at speeds higher than 1750 RPM shall not be acceptable. OSHA approved belt guards shall be provided. |
N/A
The system shall include an ASME air receiver rated for 200 PSI MAWP. The tank shall be equipped with:
|
N/A
The control system provides automatic lead/lag sequencing and automatic alternation of all compressors in order to equalize the amount of usage among the available compressors. The Premium NFPA Control Panel shall include a gateway server card and all features listed below:
|
N/A The air purification package shall consist of the following: dual desiccant air dryers, dual filter and regulator bank with sample ports, and dew point monitor with alarms, and all bypass piping. Piping to be brass, stainless, or type K copper, and cleaned for medical air use. All components shall be mounted piped and wired to the air receiver. |
N/A
The twin-tower, heatless desiccant air dryer is designed for a pressure dew point of -40 degrees F. Each dryer is sized to meet the full SCFM requirement of the system. The dryer shall be installed and plumbed on a common steel skid to the air receiver. The dryer design shall be of the automatic pressure swing, heatless, regenerative type and shall include a solid state cycle timer, reliable switching valve design, and purge muffler for quiet operation. Dryer controls shall include on/off/variable mode selector switch, and digital display. |
N/A
Each filter/dryer/regulator assembly shall be plumbed with bypass valves to enable service without disrupting air flow to the facility. Each assembly also includes a sample air port. The filtration systems consist of two stages of filtration as outlined above in the Desiccant Air Dryers section. Additionally, each assembly shall include:
|
N/A
Each system is completely tested before shipment and includes:
|