Dimension A |
N/A 38 in |
Dimension B |
N/A 105 in |
Dimension C |
N/A 79 in |
Number of Inlets |
N/A 2 |
Optional Inlet Size |
N/A 1 1/2 in |
Outlet Size |
N/A 3/4 in |
Type |
N/A Duplex |
Power |
N/A 7.5 hp |
Air Flow at 100 psig1 | N/A 46.2 scfm |
Tank Capacity |
N/A 120 gal |
Compressor Capacity2 | N/A 38167 Btu/hr |
Noise Level |
N/A 74 dBA |
System Full Load Current (F.L.A) at 208 V |
N/A 40.4 A |
System Full Load Current (F.L.A) at 230 V |
N/A 36.6 A |
System Full Load Current (F.L.A) at 460 V |
N/A 19.4 A |
System Weight |
N/A 2,200 lb |
Industry Standards/Certifications |
N/A UL508-A listed |
Open Scroll Air Compressor System |
N/A The package shall include multiple oil-less scroll air compressors and associated equipment. The only field connections required will be system intake if remote intake option is chosen, exhaust, and power connection at the control panel. |
N/A
Each compressor shall be belt driven oil-less rotary scroll single stage, air-cooled construction with absolutely no oil needed for operation. Direct drive compressors shall not be used.
|
N/A Each compressor shall be belt driven by a ODP NEMA construction motor. OSHA approved belt guards shall be provided. |
N/A
Maintenance feature designed for easy adjustment of belt tension from the motor side on the basemount assembly.
|
N/A
The service slide enables easy maintenance access to each pump and motor basemount without having to remove them from the system.
|
N/A
The system shall include an ASME air receiver rated for 200 PSI MAWP. The tank shall be equipped with:
|
N/A
The control system provides automatic lead/lag sequencing and automatic alternation of all compressors in order to equalize the amount of usage among the available compressors. The Premium NFPA Control Panel shall include a gateway server card and all features listed below
|
N/A The air purification package shall consist of the following: dual desiccant air dryers, dual filter and regulator bank with sample ports, and dew point monitor with alarms, and all bypass piping. Piping to be brass, stainless, or type K copper, and cleaned for medical air use. All components shall be mounted piped and wired to the air receiver. |
N/A
The twin-tower, heatless desiccant air dryer shall yield a pressure dew point of -40 ºF. The dryer shall be installed and plumbed on a common steel skid to the air receiver (400 gallon and larger tanks are mounted separately). The dryer design shall be of the automatic pressure swing, heatless, regenerative type and shall include a purge muffler for quiet operation. |
N/A
Each filter/dryer/regulator assembly shall be plumbed with bypass valves to enable service without disrupting air flow to the facility. Each assembly also includes a sample air port. The filtration systems consist of two stages of filtration as outlined above in the Desiccant Air Dryers section. Additionally, each assembly shall include:
|
N/A
Each system is completely tested before shipment and includes:
|