Length (A) |
N/A 77 in |
Width (B) |
N/A 30 in |
Height (C) |
N/A 52 in |
Inlet Connection Size |
N/A 1.5 in |
Outlet Connection Size |
N/A 1.5 in |
Pump Power |
N/A 5 hp |
Air Flow at 19 inHg1 | N/A 41 scfm |
Tank Capacity |
N/A 80 gal |
Tank Orientation |
N/A Horizontal |
Compressor Capacity |
N/A 10,838 Btu/hr |
Sound Level |
N/A 74 dBA |
System Full Load Current (F.L.A) at 208 V |
N/A 16.2 A |
System Full Load Current (F.L.A) at 230 V |
N/A 14.8 A |
System Full Load Current (F.L.A) at 460 V |
N/A 8.4 A |
System Weight |
N/A 620 lb |
Brands |
N/A Powerex® |
Electrical Panel Opening |
N/A 42 in |
Minimum Clearance for Ease of Maintenance |
N/A 24 in |
Motor Voltage |
N/A 208 to 230 V460 V |
Phase |
N/A 3 |
Power Supply Frequency |
N/A 60 Hz |
Industry Standards/Certifications |
N/A EISA NEMA |
N/A The package shall include one or two vacuum pumps and associated equipment, one ASME tank and one control panel. Each pump is factory piped to a common intake manifold. The system shall be completely tested prior to shipment. Vibration isolation pads for installation between the system mounting feet and the floor shall be included with the system. |
N/A The vacuum pumps shall be of the rotary vane aircooled design. Each vacuum pump shall be direct driven through a shaft coupling by a TEFC electric motor. Belt drives shall not be permitted. Each vacuum pump shall be air-cooled and have absolutely no water requirements. Each vacuum pump shall have an end (ultimate) vacuum of 29.3" Hg (15 torr). Lubrication shall be provided by an integral, fully recirculating oil supply that is filtered by an automotive type, spin-on oil filter. Non-re-circulating (once through) or partial re-circulating oil supply systems shall not be permitted. Each vacuum pump shall be capable of operation with standard SAE 30 weight oil. The oil separation systems hall be integral and shall consist of no less than three stages of internally installed oil and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, oil mist elimination, and smoke elimination, and shall be capable of removing 99.9+ percent of all oil and smoke particles from the exhaust gas stream. Each vacuum pump shall include a built-in, anti-suck-back valve, mounted at the pump inlet, and three sliding vanes. Each vacuum pump shall be equipped with a 10 micron inlet filter for removal of particulates. The vacuum pumps shall be mounted on vibration isolators. The system shall also include a supplementary check valve between the inlet filter and the pump. |
N/A The motor is EISA compliant, continuous duty, NEMA rated, C-face, TEFC, suitable for 208-230, or 460 V, 3 phase, 60 hertz electrical operation. |
N/A The system shall include an ASME rated receiver rated for full vacuum. The tank shall be equipped with a vacuum gauge and a manual drain. |
N/A
The system shall include a UL listed control panel in a NEMA 1 enclosure in simplex or duplex configurations utilizing a 120 V control transformer with fused primary and secondary protection. The control panel also includes the following accessories for each pump: |