Print Back

The AirGuard is a portable Grade D breathing air system which meets NFPA and OSHA requirements. It combines a three stage filter system which removes oil, water, particulate matter and odors with Carbon Monoxide, differential Dew Point and CFM flow sensors.

  • Meets OSHA Grade D breathing air requirements
  • CO and differential dew point sensors
  • Removes oil, water, solid particles, unpleasant odor and taste from the system
  • Respirator CFM and sensor flow alarms
  • Visual and audible alarm warnings
  • Datalog – OSHA compliance records
  • Portable – battery operated, rechargeable
Unit of Measure

Financing

Approve Payments

N/A Finance with Approve Payments

Specifications

Shipping Weight

N/A 31.6 lb

Model Number

N/A AGP-50-4-00-00

Maximum Inlet Pressure

N/A 150 psig

Maximum Air Flow

N/A 50 cfm

Warranty

N/A 2 years

Inlet Connection

Inlet Connection Size

N/A 0 1/2 in

Inlet Connection Type

N/A Hansen

Inlet Connection Quantity

N/A 1

Outlet Connection

Outlet Connection

N/A Hansen Quick Connect

Outlet Connection Quantity

N/A 4

Dimensions

Height (C)

N/A 19.56 in

Length

N/A 27.08 in

Depth

N/A 8.96 in

Filter

Standard Features of Filters

N/A 3-stages of filtration (5 micron, 0.01 micron, carbon absorber)

Basic Package Features

Basic Package Features

N/A

Display: Backlit, 7” diagonal color display

Alarms: User programmable

Air Flow Alarm Pt: < 5 CFM ±1 CFM

Sensor Types: Carbon Monoxide (0 to 50 ppm)                        

                         Dew Point (-20°F to ambient)

Sensor Accuracy: Carbon Monoxide: ±5% @ 10 ppm                              

                               Dew Point: ±2°F @ 50°F dew point

Sensor Response Time: <60 seconds

Keypad: 3-button touch, weatherproof w/tactile feedback

Battery Life: 10 hours before recharge

Data Logging: 2 points per minute

Data Storage Medium: USB memory stick

Agency Approval: UL 61010 U.S. and Canada