Items |
5VTR20 Horizontal Base Mount, Two-Stage, Electric Motor Driven Compressor |
7VTR20 Horizontal Base Mount, Two-Stage, Electric Motor Driven Compressor |
10WTR45 Horizontal Base Mount, Two-Stage, Electric Motor Driven Compressor |
15WTR45 Horizontal Base Mount, Two-Stage, Electric Motor Driven Compressor |
5VTS35 Horizontal Base Mount, Single-Stage, Electric Motor Driven Compressor |
|||||
Power | N/A 5 hp | N/A 7.5 hp | N/A 10 hp | N/A 15 hp | N/A 5 hp | |||||
Tank Size | N/A | |||||||||
Pump | N/A VTR | N/A VTR | N/A WTR | N/A WTR | N/A VTS | |||||
Speed | N/A 1000 rpm | N/A 1300 rpm | N/A 1065 rpm | N/A 1450 rpm | N/A 740 rpm | |||||
Delivery at 125 psig | N/A 16.1 cfm | N/A 21.4 cfm | N/A 36 cfm | N/A 48.4 cfm | N/A | |||||
Delivery at 175 psig | N/A 15.8 cfm | N/A 21.2 cfm | N/A 35.4 cfm | N/A 48 cfm | N/A | |||||
Delivery at 50 psig | N/A | N/A | N/A | N/A | N/A 21.7 cfm | |||||
Delivery at 100 psig | N/A | N/A | N/A | N/A | N/A 16.8 cfm | |||||
Bore Diameter | N/A 2.56 in4.72 in | N/A 2.56 in4.72 in | N/A 3.54 in4.72 in | N/A 3.54 in4.72 in | N/A 4.72 in | |||||
Stroke Size | N/A 1.97 in | |||||||||
Length | N/A 57 1/4 in | |||||||||
Width | N/A 37 1/2 in | |||||||||
Height | N/A 37 1/8 in | |||||||||
Weight | N/A 1035 lb | N/A 1115 lb | N/A 1155 lb | N/A 1195 lb | N/A 1030 lb | |||||
General Description |
N/A
With the perfection of oil-less air technology by Champion, new applications are being developed everyday:
NFPA was created in 1896 as a standards making body. Today, over 66,000 fire safety professionals belong to the NFPA, the world’s largest and most influential fire safety organization. NFPA has published almost 300 codes and standards with the mission of preventing the loss of life and property. Topics include fire prevention equipment, extinguishing systems, inspection, residential and commercial dwellings, safety of flammable gases, and the very important National Electrical Code. |
|||||||||
Warranty |
N/A
Ensuring Dependable Performance From design... to materials selection... to construction, the Champion team strives for perfection. Knowing the critical necessity for an uninterrupted supply of oil-less compressed air, Champion craftsmen take t |
|||||||||
Champion Meets the Need | N/A The need was already there: Find a reliable way to completely eliminate any oil getting from the compressor into the delivered air stream. Champion met the challenge by applying new technology, new materials and new manufacturing techniques to our compressor design. Internal moving parts in the Champion Oil-less design are protected from wear without conventional lubrication. Crankshaft and rod bearings are lubricated by exclusive sealed, solid synthetic lubricants. The result is low maintenance, high durability and pure, oil-less air! | |||||||||
Clean Compressed Air |
N/A
Champion has always been at the forefront of air compressor technology. Champion V & W Series oil-less compressors are no exception. We offer 100% duty cycle, sealed antifriction bearings and filled PTFE rings. Champion’s continuing program of product research and development assures that your Champion compressor includes the latest advancements in oil-less technology. We can design and build a system that meets your demand. |
|||||||||
Applications | N/A Air that is produced by oil-less compressors is used to drive pneumatic devices in surgical areas, critical care areas, nurseries, operating rooms, intensive care, post operative care, emergency rooms and hyperbaric chambers. | |||||||||
Optional Features |
N/A
A wide selection of configurations and options allows you to customize the compressor system to your specific needs:
|
|||||||||
Leading Edge Technology Delivered With Responsive, Local Service |
N/A
From air intake to end use, Champion can supply all the components and systems needed for your oilless compressor application. We’re a complete systems designer, manufacturer, and supplier. When you work with Champion you get the best of both worlds. Utilizing powerful CAD systems, our application engineers will work closely with you to develop specifications and build a system to meet your needs. In turn, all installation and service is handled by locally-based representatives and distributors who are well versed in compressor technology. We maintain a worldwide sales and service network to support this effort. No one else has the experience or scope to design, build and maintain complete air management systems for medical, institutional and industrial use. Count on Champion to be your single source for oil-less air compressor technology. All Champion medical air systems meet current NFPA99 standards for health care facilities. Staying abreast of the changing regulations and requirements for medical compressed air systems is a high priority at Champion. |
|||||||||
Features |
N/A
Totally Dry Crankcase Designed to maintain continuous operation. Finned to maximize efficient heat transfer. Large cover provides easy access to internal parts for service. Piston Rings Designed for oil-less compressor service with three compression rings and two guide rings. Exclusive “O” ring bumper prevents axial movement of the guide rings and eliminates end wear. Formulated of filled PTFE material for long life and compatibility with the hardened nickel-plated, polished surface of the cylinder bore. Cast-Iron Cylinders Permanently nickel-plated and hardened to resist wear and corrosion, even under extreme operating conditions. Smooth bore, polished finish, minimizes friction and reduces heat build-up for long ring wear life. Crankshaft Cantilevered crankshaft design provides superior balance and long life. Bearings Long-lasting ball bearing design; 100% oil-less. 10,000-hour life on drive set bearings, 20,000 hours on main bearings. Valves Plated valve plates and reeds of highest grade Swedish steel extend operating life and durability. 100% Duty Cycle Operation All models are rated for 100% continuous duty cycle at 100 PSIG for single-stage units and 175 PSIG for two-stage units. Spring-Isolated Base Eliminates need for special foundations. Compressor and motor are mounted on a common inner base plate. This inner base is mounted on vibro-isolation springs to absorb all vibration. Meets NFPA guidelines for medical air compressors (Over-and-under unit configuration uses elastomeric vibro-isolators). Air-Cooled Aftercooler (Optional) Oversized, with ample reserve for cooling discharged air to within 5 - 10 degrees of ambient temperature. Enables air dryer to work at its highest efficiency. |
|||||||||
Note for CFM Delivery | N/A Units tested in accordance with CAGI/PEUROP acceptance test code PN2CPTC2. | |||||||||
Note | N/A All Units Built to ISO 9001 Standards. | |||||||||
|