Items |
![]() 0695 0550 VA 550 Insertion Type Flowmeter Web Price QUOTE
|
![]() 0553 0108 5 Meter (m) Length Connection Cable Web Price QUOTE
|
![]() 0553 0109 Connection Cable for 32.81 Feet (Ft) Length Probes with Open Ends Web Price QUOTE
|
![]() 0553 2503 16 Feet (ft) Length Ethernet Connection Cable Web Price QUOTE
|
![]() 0553 2504 32 Feet (ft) Length Ethernet Connection Cable Web Price QUOTE
|
|||||
Description |
N/A
Flow sensor for installation in existing compressed air or gas line of 3/4" to 40" Housing rotatable, display 180º rotatable (on the head). Settings can be modified via display, flow meter can be reset |
N/A Connection cable for probes 5 m, with open ends | N/A Connection cable for probes 32.81 ft with open ends | N/A Ethernet Connection Cable Length 16 Ft, M12 Plug X-coded (8 Pin) To Rj 45 Plug | N/A Ethernet connection cable length 32 ft, M12 plug x-coded (8 pin) to RJ 45 plug | |||||
Approve Payments |
N/A
Finance with Approve Payments |
|||||||||
Measuring Range | N/A Up to 164 ft/s, Low-Speed Version Up to 304 ft/s, Standard Version Up to 607 ft/s, Maximum Version Up to 735 ft/s, High-Speed Version | N/A | N/A | N/A | N/A | |||||
Note for Measuring Range |
N/A
Measuring range SCFM for different pipe diameters and gases All measured values related to DIN 1343 standard conditions 0º and 1013 mbar ex works. |
N/A | N/A | N/A | N/A | |||||
Accuracy | N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) | N/A | N/A | N/A | N/A | |||||
Accuracy on Request | N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) | N/A | N/A | N/A | N/A | |||||
Accuracy Indications | N/A Relative to Ambient Temperature 71.6 ºF +2 ºF, System Pressure 87 psi | N/A | N/A | N/A | N/A | |||||
Repeatability | N/A 0.25% of Measured Value (M.V.) in Case of Correct Mounting (Mounting Aid, Position, Inlet Section) | N/A | N/A | N/A | N/A | |||||
Measuring Principle | N/A Thermal Mass Flow Sensor | N/A | N/A | N/A | N/A | |||||
Response Time | N/A t 90 <3 sec | N/A | N/A | N/A | N/A | |||||
Operating/Ambient Temperature Range | N/A -4 to 158 ºF | N/A | N/A | N/A | N/A | |||||
Media Temperature Range | N/A -4 to 356 ºF | N/A | N/A | N/A | N/A | |||||
Media Temperature Range (ATEX Version) | N/A -4 to 248 ºF | N/A | N/A | N/A | N/A | |||||
Adjustment Possibilities via Display, External Hand- Held Device PI 500, PC Service Software, Remote Diagnosis | N/A Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ºC/ºF, mbar/hPa, zero point correction, leak flow volume suppression, scaling analog output 4...20 mA, pulse/alarm, error codes etc. | N/A | N/A | N/A | N/A | |||||
Standard Outputs | N/A 1 x 4 to 20 mA Analog Output (Electrically Not Isolated) Pulse Output RS 485 (Modbus-RTU) | N/A | N/A | N/A | N/A | |||||
Optional Outputs | N/A 2 x 4 to 20 mA Active HART M-Bus Mod- bus TCP Profibus DP Profinet | N/A | N/A | N/A | N/A | |||||
Burden | N/A <500 Ω | N/A | N/A | N/A | N/A | |||||
Additional Average Value Calculation | N/A For all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value | N/A | N/A | N/A | N/A | |||||
Protection Class | N/A Ingress Protection (IP 64) for ATEX II 2D Ex tb IIIC T90ºC Db Ingress Protection (IP 67) | N/A | N/A | N/A | N/A | |||||
Housing Material | N/A Die-Cast Aluminum | N/A | N/A | N/A | N/A | |||||
Sensor Tube Material | N/A Stainless Steel 1.4404 | N/A | N/A | N/A | N/A | |||||
Screw-In Thread | N/A G 1/2 in. (International Organization for Standardization (ISO 228)) National Pipe Thread (NPT) 1/2 in. PT 1/2 in. R 1/2 in. | N/A | N/A | N/A | N/A | |||||
Operating Pressure | N/A 232 psi | N/A | N/A | N/A | N/A | |||||
Special Version Operating Pressure1 | N/A 580 psi | N/A | N/A | N/A | N/A | |||||
Direct Current (DC) Supply Voltage | N/A 18 to 36 V | N/A | N/A | N/A | N/A | |||||
Power Supply | N/A 5 W | N/A | N/A | N/A | N/A | |||||
Approval | N/A ATEX II 2G Ex db IIC T4 Gb ATEX II 2D Ex tb IIIC T90 ºC Db DVGW | N/A | N/A | N/A | N/A | |||||
Advantages of Optical Keys | N/A The sensor can also be configured in the ATEX area, without the housing needing to be opened. | N/A | N/A | N/A | N/A | |||||
Special Measurement Technology Features |
N/A
|
N/A | N/A | N/A | N/A | |||||
Special Mechanical Features |
N/A
|
N/A | N/A | N/A | N/A | |||||
Connection to Different Bus Systems Options |
N/A
There are different options available for connection to modern Bus systems:
|
N/A | N/A | N/A | N/A | |||||
Additional Information |
N/A
Easy mounting/dismounting of VA 550 under pressure - without disconnection of the line - without emptying the line If there is no suitable measuring site with 1/2" ball valve, there are two simple possibilities to set up a measuring site: A Weld on a 1/2" screw neck and screw on a 1/2" ball valve B Mount spot drilling collar including ball valve By means of the drilling jig, it is possible to drill under pressure through the 1/2" ball valve into the existing pipe. The drilling chips are collected in a filter. Then the probe can be mounted. |
N/A | N/A | N/A | N/A | |||||
|