Medical Oil-less Vane Open Systems
This is a cost-effective solution for applications where oil is not desirable. The simple design requires less routine maintenance than an oil-flooded pump and has a lower initial cost compared to other dry pump designs.
Benefit & Features
Items |
VVOTD0153 1.5 HP Duplex Tankmount Oil-less Vane Open System VVOTD0153 |
VVOTD0203 2 HP Duplex Tankmount Oil-less Vane Open System VVOTD0203 |
VVOTD0303 3 HP Duplex Tankmount Oil-less Vane Open System VVOTD0303 |
VVOTD0404 5 HP Duplex Tankmount Oil-less Vane Open System VVOTD0404 |
VVOTD0504 5 HP Duplex Tankmount Oil-less Vane Open System VVOTD0504 |
|||||
Length (A) | N/A 53 in | N/A 53 in | N/A 53 in | N/A 54 in | N/A 52 in | |||||
Width (B) | N/A 34 in | N/A 34 in | N/A 36 in | N/A 36 in | N/A 37 in | |||||
Height (C) | N/A 87 in | N/A 87 in | N/A 90 in | N/A 89 in | N/A 90 in | |||||
Inlet Connection Size | N/A 1 in | N/A 1 in | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | |||||
Outlet Connection Size | N/A 1 in | N/A 1 in | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | |||||
Pump Power | N/A 1.5 hp | N/A 2 hp | N/A 3 hp | N/A 5 hp | N/A 5 hp | |||||
Air Flow at 19 inHg1 | N/A 5.3 scfm | N/A 8 scfm | N/A 13.5 scfm | N/A 17 scfm | N/A 20 scfm | |||||
Tank Capacity | N/A 80 gal | N/A 80 gal | N/A 80 gal | N/A 120 gal | N/A 120 gal | |||||
Tank Orientation | N/A Vertical | |||||||||
Compressor Capacity | N/A 3,819 Btu/hr | N/A 5,092 Btu/hr | N/A 7,638 Btu/hr | N/A 12,730 Btu/hr | N/A 12,730 Btu/hr | |||||
Sound Level | N/A 67 dBA | N/A 70 dBA | N/A 76 dBA | N/A 77 dBA | N/A 16 dBA | |||||
System Full Load Current (F.L.A) at 208 V | N/A 10.4 A | N/A 15 A | N/A 20 A | N/A 30.4 A | N/A 30.4 A | |||||
System Full Load Current (F.L.A) at 230 V | N/A 11 A | N/A 14.2 A | N/A 18.8 A | N/A 28 A | N/A 28 A | |||||
System Full Load Current (F.L.A) at 460 V | N/A 6.8 A | N/A 10 A | N/A 10.4 A | N/A 15 A | N/A 15 A | |||||
System Weight | N/A 550 lb | N/A 600 lb | N/A 830 lb | N/A 1,150 lb | N/A 1,200 lb | |||||
Brands | N/A | |||||||||
Electrical Panel Opening | N/A 42 in | |||||||||
Minimum Clearance for Ease of Maintenance | N/A 24 in | |||||||||
Motor Voltage | N/A 208 V230 V460 V | |||||||||
Phase | N/A 3 | |||||||||
Power Supply Frequency | N/A 60 Hz | |||||||||
Industry Standards/Certifications | N/A | |||||||||
Vacuum System | N/A The Powerex medical vacuum system is designed to create a suction system to remove unwanted fluids or gases from hospital/ laboratory working areas. The medical vacuum system package is compliant with the NFPA 99 requirements for Risk Category 1 systems. Each system is completely tested before shipment and includes: • Multiple vacuum pumps and associated equipment. • AMSE air receiver. • Medical control panel. Each pump is factory piped to a common intake manifold. Vibration isolation pads are included with the system. | |||||||||
Rotary Vane Vacuum Pump | N/A Each pump shall be a dry rotary vane type vacuum pump, and shall be direct-driven by a C-face integrated electric motor enclosed in the pump housing and cooled by the pump fan. • Each vacuum pump shall be dry-running, featuring self-lubricating carbon/graphite vanes and shall not require any sealing fluid in the pumping chamber. • Each vacuum pump shall include an internal relief valve, a check valve, inlet and discharge flex connectors, a 5 micron inlet filter and a pump isolation valve. | |||||||||
Motor | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. | |||||
Receiver | N/A The system shall include an ASME rated air receiver. The tank shall be equipped with a vacuum gauge, a sight gauge, by-pass valves, and a manual drain. Optional internal tank lining for corrosion resistance. | |||||||||
Control Panel | N/A The control system provides automatic lead/lag sequencing and automatic alternation of all pumps in order to equalize the amount of usage among the available vacuum pumps. The Premium NFPA Control panel shall include a gateway server card and all features listed below: • PLC controller and a color touch screen panel which displays the operating status of the unit. • Building automation communication gateway with BacNet® protocol and Web server features. Web servers features include email notifications in case the system is in alarm or has achieved one its maintenance intervals and requires service. • Ethernet port for connection to BacNet® server or direct connection to facility Ethernet for viewing of system operations and status via device IP-address. • UL508A listed control panel in a NEMA 12 enclosure. The panel door will include: the HMI touch screen, an audible and visual alarms with an acknowledge button, and an HOA switch for each pump. • Magnetic starters. • Vacuum transducer for process control. • Single point power connection. • Redundant 120Vac control transformers with fused primary and secondary protection. • System overload trip, high temperature conditions or maintenance intervals for the pump will result in visual and audible alarms. | |||||||||
Available Options | N/A | |||||||||
Note | N/A 3 Year Limited Warranty | |||||||||
|