Items |
![]() 0699 0501 FA 500, -112 to 68 Degree Fahrenheit (ºF) Measuring Range (Atmospheric Pressure) Dew Point Sensor Web Price Quote
|
![]() 0699 0502 FA 500, -76 to 86 Degree Fahrenheit (ºF) Measuring Range (Atmospheric Pressure) Dew Point Sensor Web Price Quote
|
![]() 0699 0503 FA 500, -4 to 122 Degree Fahrenheit (ºF) Measuring Range (Atmospheric Pressure) Dew Point Sensor Web Price Quote
|
![]() 0553 0106 16 Feet (ft) Length Cable for Alarm/Pulse Output Web Price Quote
|
![]() 0553 0107 32.81 Feet (ft) Length Cable for Alarm/Pulse Output Web Price Quote
|
|||||
Description | N/A FA 500 is the ideal dew point measuring instrument with integrated display and alarm relay for refrigeration, membrane and adsorption dryers. | N/A FA 500 is the ideal dew point measuring instrument with integrated display and alarm relay for refrigeration, membrane and adsorption dryers. | N/A FA 500 is the ideal dew point measuring instrument with integrated display and alarm relay for refrigeration, membrane and adsorption dryers. | N/A Cable for alarm/pulse output, with M12 plug, length 16 ft | N/A Cable for alarm/pulse output, with M12 plug, length 32.81 ft | |||||
Approve Payments |
N/A
Finance with Approve Payments |
|||||||||
Length | N/A | N/A | N/A | N/A 16 ft | N/A 32.81 ft | |||||
Voltage | N/A | |||||||||
Frequency | N/A | |||||||||
Alternating Current (AC) Voltage | N/A | |||||||||
Direct Current (DC) | N/A | |||||||||
Measuring Range (Atmospheric Pressure) | N/A -112 to 68 ºF | N/A -76 to 86 ºF | N/A -4 to 122 ºF | N/A | N/A | |||||
Relative Humidity | N/A | N/A | N/A 100 % | N/A | N/A | |||||
Accuracy (±) at 122 to -4 Degree Fahrenheit (ºF) Temperature | N/A 1.8 ºF | N/A 1.8 ºF | N/A 1.8 ºF | N/A | N/A | |||||
Accuracy (±) at -4 to -58 Degree Fahrenheit (ºF) Temperature (Atmospheric Pressure) | N/A 3.6 ºF | N/A 3.6 ºF | N/A 3.6 ºF | N/A | N/A | |||||
Accuracy (±) at -58 to -112 Degree Fahrenheit (ºF) Temperature (Atmospheric Pressure) | N/A 5.4 ºF | N/A 5.4 ºF | N/A 5.4 ºF | N/A | N/A | |||||
Pressure Range | N/A -1 to 50 bar | N/A -1 to 50 bar | N/A -1 to 50 bar | N/A | N/A | |||||
Pressure Range (Special Version) | N/A 7251 psi | N/A 7251 psi | N/A 7251 psi | N/A | N/A | |||||
Direct Current (DC) Voltage | N/A 10 to 36 V24 V | N/A 10 to 36 V24 V | N/A 10 to 36 V24 V | N/A | N/A | |||||
Protection Class | N/A IP 65 | N/A IP 65 | N/A IP 65 | N/A | N/A | |||||
Electromagnetic Compatibility (EMC) | N/A In According with DIN EN 61326-1 | N/A In According with DIN EN 61326-1 | N/A In According with DIN EN 61326-1 | N/A | N/A | |||||
Operating Temperature | N/A -4 to 122 ºF | N/A -4 to 122 ºF | N/A -4 to 122 ºF | N/A | N/A | |||||
Connection | N/A 2 x M12, 5-pin for analog output, Modbus-RTU and alarm output, M-Bus (optional) Ethernet (PoE) (optional) | N/A 2 x M12, 5-pin for analog output, Modbus-RTU and alarm output, M-Bus (optional) Ethernet (PoE) (optional) | N/A 2 x M12, 5-pin for analog output, Modbus-RTU and alarm output, M-Bus (optional) Ethernet (PoE) (optional) | N/A | N/A | |||||
Personal Computer (PC) Connection | N/A Modbus-RTU interface (RS 485) | N/A Modbus-RTU interface (RS 485) | N/A Modbus-RTU interface (RS 485) | N/A | N/A | |||||
Analog Output | N/A 4 to 20 mA = -112 to 68 °Ftd 4 to 20 mA = -4 to 122 °Ftd 4 to 20 mA = -76 to 86 °Ftd | N/A 4 to 20 mA = -112 to 68 °Ftd 4 to 20 mA = -4 to 122 °Ftd 4 to 20 mA = -76 to 86 °Ftd | N/A 4 to 20 mA = -112 to 68 °Ftd 4 to 20 mA = -4 to 122 °Ftd 4 to 20 mA = -76 to 86 °Ftd | N/A | N/A | |||||
Burden for Analog Output | N/A < 500 Ω | N/A < 500 Ω | N/A < 500 Ω | N/A | N/A | |||||
Alarm Relay | N/A NC, max. 60 VDC, 0.5 A | N/A NC, max. 60 VDC, 0.5 A | N/A NC, max. 60 VDC, 0.5 A | N/A | N/A | |||||
Screw-In Thread | N/A G 1/2 in. | N/A G 1/2 in. | N/A G 1/2 in. | N/A | N/A | |||||
Width | N/A 3.01 in | N/A 3.01 in | N/A 3.01 in | N/A | N/A | |||||
Depth | N/A 3.35 in | N/A 3.35 in | N/A 3.35 in | N/A | N/A | |||||
Height | N/A 2.95 in | N/A 2.95 in | N/A 2.95 in | N/A | N/A | |||||
Material | N/A | |||||||||
Type | N/A | |||||||||
Special Features |
N/A
|
N/A
|
N/A
|
N/A | N/A | |||||
Readable via Modbus |
N/A
|
N/A
|
N/A
|
N/A | N/A | |||||
Easy Operation Via Keys on Display |
N/A
The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages. The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered. The 4 to 20 mA analog output can be scaled freely or also allocated to one further parameter, e. g. g/m³. After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desired. |
N/A
The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages. The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered. The 4 to 20 mA analog output can be scaled freely or also allocated to one further parameter, e. g. g/m³. After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desired. |
N/A
The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages. The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered. The 4 to 20 mA analog output can be scaled freely or also allocated to one further parameter, e. g. g/m³. After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desired. |
N/A | N/A | |||||
Options |
N/A
item-74026 item-74027 item-74028 item-74012 item-74013 item-74014 item-74015 item-74016 |
N/A
item-74026 item-74027 item-74028 item-74012 item-74013 item-74014 item-74015 item-74016 |
N/A
item-74026 item-74027 item-74028 item-74012 item-74013 item-74014 item-74015 item-74016 |
N/A | N/A | |||||
|