Passat ('G') Series Compressor/Boosters have been engineered with a gastight crankcase ('special' double crankshaft seals and jointing) to prevent gas leakage, and are oil-lubricated, single acting reciprocating compressors with air-cooling. The 'G' series compressor/boosters are similar in performance to the 'H' series but are designed for noble gases such as Helium and Argon, and hazardous gases such as Carbon Monoxide and Natural Gas. Oil pressure fed to the crankshaft bearings and oil splash for compression, combined with Sauer regulated oil injection system for the final piston plunger design, ensures high reliability. The ability to handle elevated suction pressure for both noble or hazardous gases, gives enhanced performance to final pressures between 290 - 580 PSI reliably in three stages and from 1450 - 5075 PSI in four stages within the gas flow rate range of 5.9 - 236 SCFM. Models Available in ATEX Version: WP156L, WP276L, WP316L
Unit of Measure
Specifications
Stages/Cylinders |
N/A 3 |
Models |
N/A WP101L WP121L WP126L WP151 WP156L WP206L WP271L WP276L WP311L, WP316L WP66L WP81L |
Operating Pressure Range |
N/A 150 to 1150 psi |
Required Power |
N/A 20 to 100 hp |
Flow Rate |
N/A 39 to 178 scfm |
Features
Multi-Stage Oil-Lubricated Piston Compressor |
N/A Standard |
Inter-Stage and Final After-Cooler with Oil/Water Separators |
N/A Standard |
Over-Pressure Safety Valves at Each Stage |
N/A Standard |
Gas-Tight Over-Pressure Safety Valves at Each Stage (Piped Exit and Manifold) |
N/A Standard |
Automatic Oil/Water Drain Valves |
N/A Standard |
Auto-Starting Relief Integrated with Drain System |
N/A Standard |
Pressure Indicator at Each Stage |
N/A Standard |
Gas Over-Temperature Protective Shutdown Sensor |
N/A Standard |
Oil Lubrication Including Protection Sensor |
N/A Standard |
Pressure and Temperature Indicators and Sensor-Switch at All Stages |
N/A Optional |
Air-Blast Cooling Fan and Flywheel |
N/A Standard |
Lubricating Oil Level Alarm |
N/A Optional |
Gas Suction Connection (Flange and Pipe) |
N/A Standard |
Crankcase Oil Sump Heating |
N/A Optional with Non-Explosion Proof Model only, Not available in Explosion Proof Model |
Ex-Proof Crankcase Oil Sump Heating |
N/A Optional with Explosion Proof Model only, Not available in Non-Explosion Proof Model |
Flexible Drive Coupling |
N/A Standard |
Direct Drive Electric Motor |
N/A Standard with Non-Explosion Proof model only, Not available with Explosion Proof Model |
Direct-Drive Ex-Motor (Atex) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Resilient AV Mounts |
N/A Standard |
Outlet Flexible Hose with Non-Return Valve |
N/A Standard |
Flexible Oil/Water Drain Hose |
N/A Standard |
Auto Start-Stop Pressure Sensor Control |
N/A Optional |
Oil/Water Drain Gas Separator 'Demister' Vessel |
N/A Optional |
Oil/Water Collection Tank |
N/A Optional |
Oil/Water Collection Tank (Level Alarm) |
N/A Optional |
Electrical Control Panel (Safe Area, Start/Stop, Alarms, and Shutdowns) |
N/A Optional |
Acoustic Enclosure (Internal Heater, Fan Ventilation, and Gas Detection) |
N/A Optional |
Ex-Proof Drive Coupling (Atex 95) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Anti-Static Air-Blast Cooling Fan (Atex 95) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Intrinsic Safe Relays for Pressure and Temperature Monitoring |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Intrinsic Safe Terminal Box for Electrical Connections |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Electrical Control Panel to Atex Zone 1 and 2 |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Supply Gas Pressure Sensor Control (Auto-Stop/Restart) |
N/A Optional |
Supply Gas Isolating Valve (Manual, Solenoid, Actuator, and Electrical Inter-Lock) |
N/A Optional |
Supply Gas Non-Return Valve |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
Supply Gas Excess Flow Valve |
N/A Optional with Explosion Proof Model only. Not available in Non-Explosion Proof Model |
In-Line Gas Suction Filter |
N/A Optional |
Suction Gas Regulation (Pressure Reducing Valve) |
N/A Optional |
Suction Gas Shut-Off Valve (Solenoid and Actuated) |
N/A Optional |
Capacity Control (Re-Cycling By-Pass Valve and Discharge Back to Suction) |
N/A Optional |
Inlet Gas Pulsation Damper (Suction 'Buffer Tank' Inc. Drain/Purge Valve) |
N/A Standard |
Suction Gas Protection (Safety Valve, Pressure Gauge, and High/Low Pressure Sensor-Switch) |
N/A Standard |
Flexible Suction Gas Hose |
N/A Optional |
Outlet Oil Coalescing Filtration (Manual and Auto Drain) |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Outlet Oil Vapor Activated Carbon Filtration (Manual Drain) |
N/A Optional |
Outlet Purge Connection |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Final Pressure Maintaining Valve |
N/A Standard with Explosion Proof Model, Optional with Non-Explosion Proof Model only |
Gas Drying (Suction and Outlet Hp Dryer) |
N/A Optional |
Auto Stop/Start Pressure Sensor Control |
N/A Optional |
Gas Recovery, or 'Blow-Down' Vessel (Purge, Drain, Safety Valve, and Pressure Gauge) |
N/A Standard |