Hurricane Series Compressors are used for Air or Nitrogen compression. Each compressor is an air-cooled, single acting, four stage, reciprocating piston compressor with the combination of oil pressure fed crankshaft bearings, and cylinder oil splash with regulated injection for the final high-pressure piston plunger design. Performance with inert gases, such as Nitrogen.
Unit of Measure
Specifications
Stages/Cylinders |
N/A 4 |
Models |
N/A WP4331 WP4341 WP4351 |
Operating Pressure Range |
N/A 1750 to 5800 psi |
Required Power |
N/A 20 to 75 hp |
Flow Rate |
N/A 18 to 70 scfm |
Features
Multi-Stage Oil-Lubricated Piston Compressor |
N/A Standard |
Inter-Stage and Final After-Cooler with Oil/Water Separators |
N/A Standard |
Over-Pressure Safety Valves at Each Stage |
N/A Standard |
Gas-Tight Over-Pressure Safety Valves at Each Stage (Piped Exit and Manifold) |
N/A Optional |
Automatic Oil/Water Drain Valves |
N/A Standard |
Auto-Starting Relief Integrated with Drain System |
N/A Standard |
Pressure Indicator at Each Stage |
N/A Optional |
Gas Over-Temperature Protective Shutdown Sensor |
N/A Standard |
Oil Lubrication Including Protection Sensor |
N/A Optional |
Pressure and Temperature Indicators and Sensor-Switch at All Stages |
N/A Standard |
Air-Blast Cooling Fan and Flywheel |
N/A Standard |
Lubricating Oil Level Alarm |
N/A Standard |
Gas Suction Connection (Flange and Pipe) |
N/A Standard |
Crankcase Oil Sump Heating |
N/A Optional |
Flexible Drive Coupling |
N/A Standard |
Direct Drive Electric Motor |
N/A Standard |
Direct-Drive Ex-Motor (Atex) |
N/A Optional |
Resilient AV Mounts |
N/A Standard |
Outlet Flexible Hose with Non-Return Valve |
N/A Standard |
Flexible Oil/Water Drain Hose |
N/A Standard |
Auto Start-Stop Pressure Sensor Control |
N/A Standard |
Oil/Water Drain Gas Separator 'Demister' Vessel |
N/A Optional |
Oil/Water Collection Tank |
N/A Optional |
Oil/Water Collection Tank (Level Alarm) |
N/A Optional |
Electrical Control Panel (Safe Area, Start/Stop, Alarms, and Shutdowns) |
N/A Optional |
Acoustic Enclosure (Internal Heater, Fan Ventilation, and Gas Detection) |
N/A Optional |
Ex-Proof Drive Coupling (Atex 95) |
N/A Optional |
Anti-Static Air-Blast Cooling Fan (Atex 95) |
N/A Optional |
Electrical Control Panel to Atex Zone 1 and 2 |
N/A Optional |
Supply Gas Pressure Sensor Control (Auto-Stop/Restart) |
N/A Optional |
Supply Gas Isolating Valve (Manual, Solenoid, Actuator, and Electrical Inter-Lock) |
N/A Optional |
In-Line Gas Suction Filter |
N/A Optional |
Suction Gas Regulation (Pressure Reducing Valve) |
N/A Optional |
Suction Gas Shut-Off Valve (Solenoid and Actuated) |
N/A Optional |
Capacity Control (Re-Cycling By-Pass Valve and Discharge Back to Suction) |
N/A Optional |
Inlet Gas Pulsation Damper (Suction 'Buffer Tank' Inc. Drain/Purge Valve) |
N/A Optional |
Suction Gas Protection (Safety Valve, Pressure Gauge, and High/Low Pressure Sensor-Switch) |
N/A Optional |
Flexible Suction Gas Hose |
N/A Optional |
Outlet Oil Coalescing Filtration (Manual and Auto Drain) |
N/A Optional |
Outlet Oil Vapor Activated Carbon Filtration (Manual Drain) |
N/A Optional |
Outlet Purge Connection |
N/A Optional |
Final Pressure Maintaining Valve |
N/A Optional |
Gas Drying (Suction and Outlet Hp Dryer) |
N/A Optional |
Auto Stop/Start Pressure Sensor Control |
N/A Optional |