Specifications
Shipping Weight |
N/A 560 lb |
Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 95 %96 %97 %98 %99 %99.5 %99.9 %99.95 %99.975 %99.99 %99.995 %99.999 % |
Design Operating Pressure Range |
N/A 87 to 232 psig |
Design Operating Temperature Range |
N/A 41 to 122 ºF |
Maximum Inlet Particulate |
N/A 0.1 µm |
Maximum Inlet Pressure Dew Point (PDP) |
N/A 80 ºF |
Maximum Inlet Oil Content |
N/A 0.01 ppm |
Maximum Outlet Pressure Dew Point (PDP) |
N/A -40 ºF |
Alternating Current (AC) Voltage |
N/A 120 to 240 V |
Direct Current (DC) Voltage |
N/A 24 V |
Power Supply Frequency |
N/A 50 Hz60 Hz |
Warranty |
N/A 2 years |
Note
Note |
N/A
For Rated Outlet Flow: At 100 psig inlet pressure and 68 - 77ºF (20 - 25ºC) inlet temperature. For Maximum Inlet Oil Content: Including oil vapor For Maximum Outlet Dew Point: Outlet gas dew point is < -76ºF (-60ºC) in high purity applications For Pressure Correction Factors and Temperature Correction Factors: To be used as a rough guide only. All applications should be confirmed by n-psi. Contact us for sizing assistance |
Sizing and Specifications
Rated Outlet Flow at 99.999% (10 ppm) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 83 scfh |
Rated Outlet Flow at 99.995% (50 ppm) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 162 scfh |
Rated Outlet Flow at 99.99% (100 ppm) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 194 scfh |
Rated Outlet Flow at 99.975 Percent (%) (250 ppm) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 256 scfh |
Rated Outlet Flow at 99.95% (500 ppm) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 307 scfh |
Rated Outlet Flow at 99.9% (0.10%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 350 scfh |
Rated Outlet Flow at 99.5% (0.50%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 509 scfh |
Rated Outlet Flow at 99% (1%) Nitrogen Purity at the Outlet (Maximum Oxygen Content) |
N/A 604 scfh |
Dimension A |
N/A 47.8 in |
Dimension B |
N/A 15.7 in |
Dimension C |
N/A 36.2 in |
Pressure Correction Factors
Operating Pressure |
N/A 100 psig115 psig130 psig145 psig90 psig |
Pressure Correction Factor at 90 psi (6 barg) Operating Pressure |
N/A 0.90 |
Pressure Correction Factor at 100 psi (7 barg) Operating Pressure |
N/A 1.00 |
Pressure Correction Factor at 115 psi (8 barg) Operating Pressure |
N/A 1.10 |
Pressure Correction Factor at 130 psi (9 barg) Operating Pressure |
N/A 1.20 |
Pressure Correction Factor at 145 psi (10 barg) Operating Pressure |
N/A 1.25 |
Temperature Correction Factor
Inlet Temperature |
N/A 50 to 75 ºF85 ºF95 ºF105 ºF |
Correction Factor at 10 ppm O2 and 50 to 75 ºF Inlet Temperature |
N/A 1.00 |
Correction Factor at 10 ppm O2 and 85 ºF Inlet Temperature |
N/A 0.90 |
Correction Factor at 10 ppm O2 and 95 ºF Inlet Temperature |
N/A 0.81 |
Correction Factor at 10 ppm O2 and 105 ºF Inlet Temperature |
N/A 0.66 |
Correction Factor at 50 to 500 ppm O2 and 50 to 75 ºF Inlet Temperature |
N/A 1.00 |
Correction Factor at 50 to 500 ppm O2 and 85 ºF Inlet Temperature |
N/A 0.98 |
Correction Factor at 50 to 500 ppm O2 and 95 ºF Inlet Temperature |
N/A 0.86 |
Correction Factor at 50 to 500 ppm O2 and 105 ºF Inlet Temperature |
N/A 0.75 |
Correction Factor at 0.1 to 5.0% O2 and 50 to 75 ºF Inlet Temperature |
N/A 1.00 |
Correction Factor at 0.1 to 5.0% O2 and 85 ºF Inlet Temperature |
N/A 0.98 |
Correction Factor at 0.1 to 5.0% O2 and 95 ºF Inlet Temperature |
N/A 0.95 |
Correction Factor at 0.1 to 5.0% O2 and 105 ºF Inlet Temperature |
N/A 0.90 |
Additional Information
N/A
Leading edge technology and hundreds of years of experience…nano-purification solutions, your world-class manufacturer of state-of-the-art compressed air and gas solutions to industry. |
Dry and Pure
N/A
Nitrogen is used in many commercial and industrial applications to improve the quality of a product or process or as a safety measure to prevent combustion. Liquid or bottled nitrogen delivery and storage can be expensive, unreliable and a safety concern. Nitrogen generators allow users to produce nitrogen in-house simply and inexpensively using an existing compressed air system. |
Design
N/A Our experienced team of design engineers are always looking for new and unique technologies and products to bring you the highest level of performance and lowest overall operating cost. |
Research and Development
N/A Our R&D team endeavor to provide solutions that go beyond developing an existing product. They are continually researching new technologies which can provide unique advantages over competitive offerings. |
Manufacture
N/A The reliable and energy saving nano GEN2 range of nitrogen generators are manufactured in our state of the art facility to the highest standards of build quality to ensure equipment reliability and high levels of performance. |
Benefits - Get More for Your Money
Guaranteed Performance |
N/A
|
Rapid Return on Investment |
N/A
|
Easy to Install |
N/A
|
Safe & Reliable |
N/A
|
Environmentally Friendly |
N/A
|
Easy to Maintain |
N/A
|
Fits any Application |
N/A
|
Design Quality |
N/A
|
Ecomode Energy Saving Control
N/A This unique control feature utilizes an outlet pressure monitor to reduce energy consumption during periods of low demand to ensure a continuous uninterrupted nitrogen supply while minimizing power consumption. |
PLC Controlled Operation
N/A Each GEN2 nitrogen generator is operated by a reliable PLC control system with digital and analog outputs for remote monitoring and alarm capabilities. GEN2 includes an easy-to-operate touch screen graphical interface which offers valuable features including 'power on', 'hours run', 'oxygen purity', 'pressure', 'online column' and 'service required' indicators. In addition, four pressure gauges provide the operator with continuous indication of column A, column B, air inlet and nitrogen outlet pressures. |
Multi-Bank Design
N/A The unique multi-bank design (GEN2-1110 to GEN2-12130) enables additional generators to be added in the future as demand increases. Your GEN2 nitrogen generator can grow with your company. |
Reliable High Performance Valves
N/A
Inlet, outlet and exhaust are managed through unique integrated nano piston valves, which are designed for reliability, long service life and ease of maintenance. The generator also incorporates adjustable equalization valves which smooth the column switch over, improve air/ N2 ratios and extend CMS life. This highly durable valve system is backed by a comprehensive two-year warranty. |
Maximum Corrosion Protection
N/A High tensile aluminum columns are first alocromed and then powder coated to provide maximum protection for corrosive environments. |
Oxygen Analyzer
N/A A built in oxygen analyzer continuously monitors the oxygen concentration in the nitrogen stream. Our NEW remote mounted analyzer utilizes Zirconia Sensor Technology to give a more reliable measurement, faster response time and longer life compared to traditional analyzers. Incorporated into the PLC controls, our oxygen analyzer guarantees downstream purity levels are consistently achieved and maintained. |
System Performance
N/A
The technologically advanced nano GEN2 nitrogen generator operates on the Pressure Swing Adsorption (PSA) principle to produce a continuous uninterrupted stream of nitrogen gas from clean dry compressed air. |