No inlet section necessary - integrated flow straightener - sensor unit removable
The newly developed VA 521 combines modern digital interfaces for connection to energy monitoring systems with a small, compact design. The VA 521 is always used when many machines (compressed air consumers) are to be integrated into an energy monitoring network.
Readout values in the display can be rotated by 180º, e.g. for overhead installation
The sensor can be removed from the measuring section and cleaned.
The newly developed VA 521 combines modern digital interfaces for connection to energy monitoring systems with a small, compact design. The VA 521 is always used when many machines (compressed air consumers) are to be integrated into an energy monitoring network.
Readout values in the display can be rotated by 180º, e.g. for overhead installation
The sensor can be removed from the measuring section and cleaned.
Unit of Measure
Financing
|
Specifications
|
Measuring Range
|
Display Shows 2 Values at the Same Time
|
Screw-In Thread
|
Advantages at a Glance
|
With a Key Stroke
Specifications
Parameters |
N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 ºC) in case of gases |
Units Adjustable Via Keys at Display |
N/A CFM ft/min g/s kg/h kg/min l/s lb/h lb/min m/s m³/h m³/min |
Sensor |
N/A Thermal Mass Flow Sensor |
Measured Medium |
N/A Air Gases |
Gas Types are Adjustable Over CS Service Software or CS Data Logger |
N/A Air Argon CO2 Nitrogen Oxygen |
Accuracy |
N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.) |
Accuracy on Request |
N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) |
Operating Temperature |
N/A -22 to 176 ºF |
Operating Temperature with Pressure Sensor |
N/A -25 to 349 ºF |
Operating Pressure |
N/A Up to 232 psi |
Optional Pressure |
N/A Up to 580 psi |
Digital Output |
N/A Modbus-Remote Terminal Unit (RTU) RS 485 Interface |
Optional Digital Output |
N/A Ethernet Interface M-Bus Power over Ethernet (PoE) |
Analog Output for Cubic Feet Per Minute (CFM) |
N/A 4 to 20 mA |
Pulse Output |
N/A 1 pulse per CF or per liter electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay. |
Direct Current (DC) Supply Voltage |
N/A 18 to 36 V |
Power Supply |
N/A 5 W |
Burden |
N/A <500 Ω |
Housing Material |
N/A Polycarbonate |
Protection Rating |
N/A Ingress Protection (IP 65) |
Material |
N/A Aluminum Stainless Steel 316L |
Mounting Position |
N/A Any |
Measuring Range
Measuring Section |
N/A DN15 |
Thread Size |
N/A G 1/2 in. |
Measuring Range Full Scales |
N/A 90 m³/h50 ft³/min |
Dimension L |
N/A 135 mm |
Dimension B |
N/A 55 mm |
Dimension H1 |
N/A 50 mm |
Dimension H |
N/A 109.65 mm |
Dimension A1 |
N/A 25 mm |
Dimension A |
N/A 20 mm |
Note for Measuring Range |
N/A
Flow measuring ranges VA 521 (max version 185 m/s) for compressed air (ISO 1217:1000 mbar, 20 ºC) Measuring ranges for other types of gas. |
Display Shows 2 Values at the Same Time
Display Shows 2 Values at The Same Time |
N/A
|
Screw-In Thread
Screw-In Thread |
N/A Easy installation into the existing pipe due to integrated measuring section (suitable for 1/2", 3/4", 1", 1 1/4", 1 1/2" or 2" lines) |
Advantages at a Glance
Advantages at a Glance |
N/A
|