Display shows 2 values at the same time:
  • Present flow in m³/h, CFM
  • Total consumption (counter reading) in CF
  • Temperature measurement
Readout values in the display can be rotated by 180º, e.g. for overhead installation.
Unit of Measure

Financing

Approve Payments

N/A Finance with Approve Payments

Specifications

Parameters

N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 ºC) in case of gases

Units Adjustable Via Keys at Display

N/A CFM ft/min g/s kg/h kg/min l/s lb/h lb/min m/s m³/h m³/min

Sensor

N/A Thermal Mass Flow Sensor

Measured Medium

N/A Air Gases

Gas Types are Adjustable Over CS Service Software or CS Data Logger

N/A Air Argon CO2 Nitrogen Oxygen

Accuracy

N/A ± 0.3% of Full Scale (F.S.) ± 1.5% of Measured Value (M.V.)

Accuracy on Request

N/A ± 1.0% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.)

Operating Temperature

N/A -22 to 176 ºF

Operating Temperature with Pressure Sensor

N/A -25 to 349 ºF

Operating Pressure

N/A -1 to 232 psi

Optional Pressure

N/A Up to Nominal Pressure (PN) 40

Digital Output

N/A M-Bus Modbus-Remote Terminal Unit (RTU) Optional: Ethernet Interface (PoE) RS 485 Interface

Analog Output for Cubic Feet Per Minute (CFM)

N/A 4 to 20 mA

Pulse Output

N/A 1 pulse per CF or per liter electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay.

Direct Current (DC) Supply Voltage

N/A 18 to 36 V

Power Supply

N/A 5 W

Burden

N/A <500 Ω

Housing Material

N/A Polycarbonate

Protection Rating

N/A Ingress Protection (IP 65)

Material

N/A Stainless Steel 1.4404

Mounting Position

N/A Any

Dimension L (Thread)

N/A 475 mm18.7 in

Measuring Range

Low-Speed Air Flow (164 Feet Per Seconds (ft/s))

N/A 320 L/min190 ft³/min

Standard Air Flow (304 Feet Per Seconds (ft/s))

N/A 600 m³/h350 ft³/min

Maximum Air Flow (607 Feet Per Seconds (ft/s))

N/A 1195 m³/h700 ft³/min

High-Speed Air Flow (735 Feet Per Seconds (ft/s))

N/A 1450 m³/h850 ft³/min

Note for Air Flow

N/A Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi

Low-Speed Argon (Ar) Flow (164 Feet Per Seconds (ft/s))

N/A 505 L/min295 ft³/min

Standard Argon (Ar) Flow (304 Feet Per Seconds (ft/s))

N/A 935 m³/h550 ft³/min

Maximum Argon (Ar) Flow (607 Feet Per Seconds (ft/s))

N/A 1870 m³/h1100 ft³/min

High-Speed Argon (Ar) Flow (735 Feet Per Seconds (ft/s))

N/A 2265 m³/h1330 ft³/min

Note for Argon (Ar) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Carbon Dioxide (CO2) Flow (164 Feet Per Seconds (ft/s))

N/A 320 L/min185 ft³/min

Standard Carbon Dioxide (CO2) Flow (304 Feet Per Seconds (ft/s))

N/A 590 m³/h345 ft³/min

Maximum Carbon Dioxide (CO2) Flow (607 Feet Per Seconds (ft/s))

N/A 1185 m³/h695 ft³/min

High-Speed Carbon Dioxide (CO2) Flow (735 Feet Per Seconds (ft/s)

N/A 1430 m³/h840 ft³/min

Note for Carbon Dioxide (CO2) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Nitrogen (N2) Flow (164 Feet Per Seconds (ft/s))

N/A 505 L/min300 ft³/min

Standard Nitrogen (N2) Flow (304 Feet Per Seconds (ft/s))

N/A 550 m³/h320 ft³/min

Maximum Nitrogen (N2) Flow (607 Feet Per Seconds (ft/s))

N/A 1100 m³/h645 ft³/min

High-Speed Nitrogen (N2) Flow (735 Feet Per Seconds (ft/s))

N/A 1330 m³/h780 ft³/min

Note for Nitrogen (N2) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Oxygen (O2) Flow (164 Feet Per Seconds (ft/s))

N/A 305 L/min180 ft³/min

Standard Oxygen (O2) Flow (304 Feet Per Seconds (ft/s))

N/A 570 m³/h335 ft³/min

Maximum Oxygen (O2) Flow (607 Feet Per Seconds (ft/s))

N/A 1140 m³/h670 ft³/min

High-Speed Oxygen (O2) Flow (735 Feet Per Seconds (ft/s))

N/A 1380 m³/h810 ft³/min

Note for Oxygen (O2) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Nitrous Oxide (N2O) Flow (164 Feet Per Seconds (ft/s))

N/A 315 L/min185 ft³/min

Standard Nitrous Oxide (N2O) Flow (304 Feet Per Seconds (ft/s))

N/A 585 m³/h345 ft³/min

Maximum Nitrous Oxide (N2O) Flow (607 Feet Per Seconds (ft/s))

N/A 1170 m³/h690 ft³/min

High-Speed Nitrous Oxide (N2O) Flow (735 Feet Per Seconds (ft/s))

N/A 1420 m³/h835 ft³/min

Note for Nitrous Oxide (N2O) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Natural Gas (NG) Flow (164 Feet Per Seconds (ft/s))

N/A 190 L/min110 ft³/min

Standard Natural Gas (NG) Flow (304 Feet Per Seconds (ft/s))

N/A 355 m³/h205 ft³/min

Maximum Natural Gas (NG) Flow (607 Feet Per Seconds (ft/s))

N/A 705 m³/h415 ft³/min

High-Speed Natural Gas (NG) Flow (735 Feet Per Seconds (ft/s))

N/A 855 m³/h500 ft³/min

Note for Natural Gas (NG) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Flange

Measuring Section

N/A 2 in

Flange Outer Pipe Diameter

N/A 60.3 mm2.37 in

Flange Inner Pipe Diameter

N/A 53.1 mm2.09 in

Dimension L (Flange)

N/A 18.7 in

Note for Dimension L (Flange)

N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site.

Dimension L1 (Flange)

N/A 10.83 in

Dimension H (Flange)

N/A 9.7 in

Dimension H1 (Flange)

N/A 6.5 in

Flange DIN EN 1092-1

Diameter D (Flange)

N/A 165 mm

Diameter K (Flange)

N/A 125 mm

Number of Diameter L (Flange)

N/A 4

Diameter L (Flange)

N/A 18 mm

Thread

Connection Thread

N/A R 2 in.

Thread Outer Pipe Diameter

N/A 60.3 mm2.37 in

Thread Inner Pipe Diameter

N/A 53.1 mm2.09 in

Note for Dimension L (Thread)

N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site!

Dimension L1 (Thread)

N/A 10.8 in275 mm

Dimension H (Thread)

N/A 7.7 in195.9 mm

Dimension H1 (Thread)

N/A 6.5 in165.7 mm

Dimension A (Thread)

N/A 1.1 in30 mm

Connection to Different Bus Systems Options

Connection to Different Bus Systems Options

N/A There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU
  • Ethernet Modbus TCP
  • M12 Ethernet port, x-coded

With a Key Stroke

With a Key Stroke

N/A
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression

Options

Options

N/A Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.

Application-Technological Features

Application-Technological Features

N/A
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus

Additional Information

N/A Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

New: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.