All Categories > Dew Point > FA 550 Dew Point Sensors > Item # 0553 0552  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Item # 0553 0552, Portable Network Graphics (PNG) Cable Screwing for FA 550 and VA 550/570

Web Price QUOTE


Image FA 550 dew point sensor - in robust die-cast aluminum housing
The FA 550 is ideal for outdoor dew point measurements or rougher industrial environment





Financing  · Specifications  · Applications  · Special Features  · Easy Operation Via Keys on Display

Financing

Approve Payments

Finance with Approve Payments



Specifications

Type

Portable Network Graphics (PNG)


Applications
  • Dew point measurement in the compressed air after adsorption dryers/membrane dryers and refrigeration dryers
  • Residual moisture measurement / dew point measurement in gases such as: oxygen, nitrogen, argon, hydrogen, natural gas, biogas




Special Features
  • Robust, waterproof die-cast aluminum housing, IP 67
  • Alarm relay - limit value adjustable via buttons (max 60 VDC, 0.5 A)
  • 4...20 mA analog output
  • Optional: 2 pieces 4 ... 20 mA analog output e.g. for dew point and temperature
  • Extremely stable in the long term
  • Quick adaption time
  • Pressure-resistant up to 7251 psi (optional)
  • NEW: Modbus-RTU interface
  • NEW: Ethernet interface (optional)
  • NEW: Higher resolution of sensor signal due to the improved evaluation electronics
  • NEW: Sensor diagnosis on site with a portable device or CS Service Software
  • Readable via Modbus: pressure dew point [ºCtd.], temperature [ºC], rel. humidity [% RH], abs. humidity [g/m³], degree of humidity [g/kg], moisture content V/V [ppm- V/V], partial vapor pressure [hPa], atmospheric dew point [ºCtd.atm]




Easy Operation Via Keys on Display
The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages.

The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered.

The 4 to 20 mA analog output can be scaled freely or also allocated to one further parameter, e. g. g/m³.

After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desired.