The DS 400 shows all 3 measuring channels according to ISO 8573-1
Particle size 0.1 to 0.5 µm: Number or particles per CF
Particle size 0.5 to 1.0 µm: Number or particles per CF
Particle size 1.0 to 5.0 µm: Number or particles per CFX
PC 400 particle counter up to 0.1 µm for compressed air and gases incl. pressure reducer and calibration certificate in a service case
Particle size 0.1 to 0.5 µm: Number or particles per CF
Particle size 0.5 to 1.0 µm: Number or particles per CF
Particle size 1.0 to 5.0 µm: Number or particles per CFX
PC 400 particle counter up to 0.1 µm for compressed air and gases incl. pressure reducer and calibration certificate in a service case
Unit of Measure
Financing
|
Specifications
|
Field of Application
|
Dimensions
|
Options
|
Advantages
|
Advantages of The DS 400
|
Additional Information
Specifications
Measured Medium |
N/A
Compressed air (free from aggressive, corrosive, acid, toxic, flammable and oxidizing components) as well as gas types like N2, O2, CO2. Further gas types on request |
Parameter |
N/A
Number of particles per m³ (relative to expanded air: 20 ºC, 1000 hPa) Size channels for the PC 400 0.1 µm: Particle size 0.1 to 0.5 µm: Number or particles per m³ Particle size 0.5 to 1.0 µm: Number or particles per m³ Particle size 1.0 to 5.0 µm: Number or particles per m³ Size channels for the PC 400 0.3 µm: Particle size 0.3 to 0.5 µm: Number or particles per m³ Particle size 0.5 to 1.0 µm: Number or particles per m³ Particle size 1.0 to 5.0 µm: Number or particles per m³ |
Maximum Input Pressure on The Pressure Reducer |
N/A 40 bar |
Humidity of Measured Gas |
N/A ≤ 90% relative humidity, pressure dew point maximum +10 ºC, non-condensable humidity |
Ambient Temperature |
N/A 5 to 40 ºC |
Temperature of The Measured Medium |
N/A 0 to 40 ºC |
Compressed Air Connection |
N/A 6 Millimeter (mm) Polytetrafluoroethylene (PTFE)-Hose Incl. Quick Coupling |
Flow Rate |
N/A 28.31 L/min1 ft³/min |
Interface |
N/A RS 485 (Modbus-RTU) |
Light Source |
N/A Laser Diode |
Direct Current (DC) Voltage |
N/A 24 V |
Direct Current (DC) |
N/A 300 mA |
Housing Material |
N/A Stainless steel |
Field of Application
Field of Application |
N/A
In case of compressed air after filtration In case of gases/pure gases also without filtration |
Options
Options |
N/A
0554 8040, CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places 0699 0041, As an alternative to PC 400 up to 0.1 ?m: PC 400 particle counter up to 0.3 ?m for compressed air and gases, incl. pressure reducer and calibration certificate Z500 4002, Integrated data logger for 100 million measured values Z500 4004, Integrated Ethernet and RS 485 interface |
Advantages
Advantages |
N/A
Advantages at a glance:
|
Advantages of The DS 400
Advantages of the DS 400 |
N/A
|