Dimensions
Dimension A |
N/A 83 in |
Dimension B |
N/A 58 in |
Dimension B1 |
N/A 37 in |
Dimension B2 |
N/A 32 in |
Dimension C |
N/A 62 in |
Dimension C1 |
N/A 84 in |
Inlet Size1 | N/A 1 1/2 in |
Outlet Size |
N/A 1 in |
Laboratory Enclosed Scroll Simplex 30 to 40 hp with Premium Controls
Power |
N/A 40 hp |
Air Flow at 100 psig2 | N/A 91.2 scfm |
Tank Capacity |
N/A 200 gal |
Compressor Capacity3 | N/A 76400 Btu/hr |
Noise Level4 | N/A 60 dBA |
System Full Load Current (F.L.A) at 208 V |
N/A 117 A |
System Full Load Current (F.L.A) at 230 V |
N/A 105 A |
System Full Load Current (F.L.A) at 460 V |
N/A 53 A |
System Weight |
N/A 2950 lb |
Specifications
Brands |
N/A Powerex® |
Type |
N/A Simplex |
Warranty (Limited) |
N/A 3 years |
Electrical Panel Opening |
N/A 42 in |
Minimum Clearance for Ease of Maintenance |
N/A 24 in |
Dew Point Temperature |
N/A -40 ºF |
Stages |
N/A 2 |
High Alarm |
N/A -20 ºF28.8 ºC |
Economy Mode |
N/A -45 ºF |
Fixed Mode |
N/A -40 ºF |
Pipe Material |
N/A Brass Stainless Steel Type K Copper |
Control Panel Protection |
N/A NEMA 12 |
Industry Standards/Certifications |
N/A ASME EISA FDA |
General
N/A
Each system is completely tested before shipment and includes:
|
Oilless Scroll Compressor Pumps
N/A
Each compressor shall be belt driven oil-less rotary scroll single stage, air-cooled construction with absolutely no oil needed for operation. Direct drive compressors shall not be used.
|
Motor
N/A Each compressor shall be belt driven by a TEFC, NEMA construction motor. Motors are EISA compliant and premium efficient. |
Main Controls
N/A
The main control panel provides power to the dryer skid, monitors, and the scroll enclosure controls. The main control panel has all the alarm contacts and operations. The system Main control panel features include the following: |
Scroll Enclosure Controls
N/A
The controls operate the simplex or duplex air compressor modules as needed in response to a pressure signal from a pressure transducer located in the system manifold. An illuminated on/off push button controls power to the motor starters. When the button is in the off position, the system is merely in stand-by mode, not powered off. |
Inlet Filters
N/A The system includes a single inlet filter with a pleated element and a canister with silencing tubes. The single inlet filter serves all the compressor modules in the system. The filter is located inside the sound reducing cabinet protected by a convenient access panel. |
Sound Reducing Enclosure
N/A The system is constructed with an internal frame and steel base system with individual vibration isolation mounted compressor modules. The sound reducing enclosure has a front access panel to allow service of the electrical controls. The enclosure has rear cooling air intake and all exhaust air leaves the enclosure from the top |
Air Receiver
N/A
The system shall include an ASME air receiver rated for 200 psi MAWP. The tank shall be equipped with:
|
Air Purification Package
N/A The air purification package shall consist of the following: dual desiccant air dryers, dual filter and regulator bank with sample ports, and dew point monitor with alarms, and all bypass piping. Piping to be brass, stainless, or type K copper, and cleaned for medical air use. All components shall be mounted piped and wired to the air receiver. |
Desiccant Air Dryers
N/A
The twin-tower, heatless desiccant air dryer shall yield a pressure dew point of -40 degrees F. The dryer shall be installed and plumbed on a common steel skid to the air receiver. The dryer design shall be of the automatic pressure swing, heatless, regenerative type and shall include a solid state cycle timer, reliable switching valve design, and purge muffler for quiet operation. Dryer controls shall include on/off/variable mode selector switch and digital display with cycle mode counter. |
Dew Point Monitor
N/A
The system-integrated hygrometer shall be equipped with an LCD dew point display and high dew point alarm with dry contacts connected to main controls panel. The sensor shall include an auto calibration feature to ensure the accuracy of the dew point measurement. Alarm set points as follows:
|
Moisture Separator
N/A The moisture separator shall be sized for the peak calculated demand and shall include an auto float drain to purge the collected moisture. |
Optional Co Monitor
N/A Carbon monoxide (CO) monitor is in an enclosure with LCD display of CO concentrations. The monitor shall continuously display the CO content of the discharge air and shall provide audible and visual high CO alarms. High alarm is set at 10 ppm. Dry contacts are provided for remote monitoring of the high CO alarm on the main control panel. |
- 1 For Remote Inlet Option
-
2 Air flow at 100 psig are shown with one pump in reserve per compressor column.
Powerex® recommends using performance ratings in SCFM ( Standard Cubic Feet per M Minute) when sizing laboratory air systems. - 3 Compressor Capacity Levels are shown with reserve compressor(s) on standby.
- 4 Noise Level is shown with all pumps running.