Dimensions
Length (A) |
N/A 57 in |
Width (B) |
N/A 66 in |
Height (C) |
N/A 82 in |
Inlet Connection Size |
N/A 2 in |
Outlet Connection Size |
N/A 1 in |
Tankmount Vacuum Systems
Pump Power |
N/A 5 hp |
Air Flow at 19 inHg1 | N/A 76 scfm |
Tank Capacity |
N/A 120 gal |
Tank Orientation |
N/A Vertcal |
Compressor Capacity |
N/A 21,676 Btu/hr |
Sound Level |
N/A 82 dBA |
System Full Load Current (F.L.A) at 208 V |
N/A 39.2 A |
System Full Load Current (F.L.A) at 230 V |
N/A 36.2 A |
System Full Load Current (F.L.A) at 460 V |
N/A 19.1 A |
System Weight |
N/A 2800 lb |
Specifications
Electrical Panel Opening |
N/A 42 in |
Minimum Clearance for Ease of Maintenance |
N/A 24 in |
Motor Voltage |
N/A 208 V230 V460 V |
Phase |
N/A 3 |
Power Supply Frequency |
N/A 60 Hz |
Vacuum System
N/A
The Powerex medical vacuum system is designed to create a suction system to remove unwanted fluids or gases from hospital/ laboratory working areas. The medical vacuum system package is compliant with the NFPA 99 requirements for Risk Category 1 systems. Each system is completely tested before shipment and includes: |
Rotary Vane Vacuum Pump
N/A
Each pump shall be a rotary claw type vacuum pump, and shall be direct-driven through a shaft coupling by a C-face, TEFC electric motor. |
Motor
N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. |
Receiver
N/A The system shall include an ASME rated air receiver. The tank shall be equipped with a vacuum gauge, a sight gauge, by-pass valves, and a manual drain. |
Control Panel
N/A
The control system provides automatic lead/lag sequencing and automatic alternation of all pumps in order to equalize the amount of usage among the available vacuum pumps. The Premium NFPA Control panel shall include a gateway server card and all features listed below: |
- 1 Air Flow shown at total system capacity.