| Shipping | Tax | Terms Shopping Cart 0 Items Request for Quote 0 Items All Categories > Kaeser Products > Blowers > BBC - FBC Rotary Lobe Blowers > Item # 73158 Download PDF Download PDF Printable Page Email This Page Save To Favorites Please wait… Item # 73158, CB 131 C Model 14.5 Pound Per Square Inch (psi) Maximum Differential Gauge Pressure Standard Version Rotary Lobe Blower Web Price QUOTE Smart design, compact, and ready for immediate useOur COMPACT blowers are optionally available as a complete package to ensure easy commissioning and maintenance as well as reliable operation:Also suitable for nitrogen conveying applications (CN versions)Complete plug-and-play systems with integrated package controls and power supply: optionally available with wye-delta start (STC) or variable speed control (OFC) Financing · Specifications · Dimensions · Advantages · Low Life Cycle Costs · Equipment · Innovative Installation Concept · Outdoor Installation - No Problem! · Accessories Financing Approve Payments Finance with Approve Payments Specifications Brands Kaeser Compressors Model CB 131 C Maximum Differential Gauge Pressure 14.5 psi Maximum Usable Flow Rate 434 ft³/min Maximum Differential Under Pressure 7.3 psi Maximum Intake Volume 438 ft³/min Maximum Rated Motor Power 40 hp Connection Diameter 80 DN Maximum Weight 1415 lb Dimensions Width with Control Cabinet and Sound Enclosure 60.2 in Depth with Control Cabinet and Sound Enclosure 45.3 in Height with Control Cabinet and Sound Enclosure 50.8 in Advantages Plug and play operation saves time and money - Blowers with integrated controls result in considerable savings for planning, installation, commissioning, data communication, and certification.Safe and reliable conveying, optimized for your needs - Our SIGMA CONTROL 2 controller not only makes complete systems more efficient, it also continually monitors and transmits performance and status data. The result: Maximum reliability and availability.Compact footprint thanks to intelligent enclosure design - COMPACT blower with sound enclosure. In the STC version, units can be installed side by side, as maintenance access is in the front and air connections are located in the back. Low Life Cycle Costs Our comprehensive approach to life cycle cost management: Superior efficiency, easy operation, service-friendliness, and the latest in technology to keep performance high well into the future. Equipment Blower Block Robust and durableEnergy-efficient Omega Profile rotorsWide control range Drive Motor IE3 high-efficiency motorThree PTC thermistors as standardCalibrated with OFC frequency controller for variable speed systemsEasily accessible, central lubrication port to regrease motor bearings for fast and safe maintenance Sound Insulation The system's blower and motor cooling air is drawn in from outside the sound enclosure from the cooler ambient surroundings for maximum energy efficiency.Effective sound-proofing provided by thick-walled lining with dense foam and dampening louvers over intake and exhaust openingsAbsorption silencer minimizes process air pulsation downstream of the blower blockLow residual pulsation for minimal sound transfer to downstream piping. Power Transmission High efficiencyV-belt guard for safe operationAutomatic belt tensioning for consistently high power transmission ratioBelt tensioning device also serves as motor lifting device when changing the belt. Sigma Control 2 SIGMA CONTROL 2 with blower-specific softwareDisplay and RFID reader provide effective communication and enhanced security.Highly flexible and easily integrates into plant control / SCADA systems thanks to the multiple available interfacesSD card reader for quick and easy updates and logging operating data ACA Aftercoolers High efficiency ACA aftercoolers specially developed by KAESER for operation with rotary blowersReduction in blowing air temperature to max. 50 ºF above ambient while maintaining optimum pressure with no cooling water requiredElectrical connection directly in the blower control cabinet. Innovative Installation Concept To save space, multiple COMPACT blower units can be installed side by side.All maintenance and installation work can be performed through the front or top of the unit.All valves are mounted directly on the blower unit.The pipe connections and cooling air apertures are located at the rear.Accessible from the front - Belt tensioning device and tension indicator (two-section belt guard for larger units)Intake filter inspection and changeMotor terminal stripOil drain and filling plug, oil level inspection Outdoor Installation - No Problem! Installing Kaeser blowers outdoors is simple and inexpensive. The specially designed shields to protect the air inlet apertures against heavy rain are equipped with a bird screen. A stainless steel roof cover also provides protection against overheating due to sun exposure. Accessories Start Control (STC) Control cabinet includes: wye-Δ starter (with remote operation capability), sound enclosure fan control, operating hours counter, and KAESER CONTROL (the interface to Kaeser's service facility). Variable Frequency Control (OFC) Frequency control enables infinite blower speed adjustment and, with the addition of a pressure sensor, also enables pressure regulation. The control unit coordinates operation of the frequency controller and the blower unit. Flexibility is further enhanced by the supplied signal output / input and Profibus connections. MORE IMAGES · ACA Aftercoolers · Blower Block · Outdoor Installation · Start Control (STC) - 2 · Innovative Installation Concept · Variable Frequency Control (OFC) · Sigma Control 2 DOWNLOADS Brochure for Rotary Lobe Blowers (PDF, 2651KB) Maintain Your Air Compressor Learn more about maintaining your air compressor by downloading our eBook on air compressor maintenance. Download eBook