ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.
Unit of Measure
Items
Image

Enmet Compressed Airline Monitor
Web Price QUOTE

Image

Enmet Compressed Airline Monitor
Web Price QUOTE

Image

Enmet Ambient Air Monitor
Web Price QUOTE

Image

Enmet Fixed Gas Detection System
Web Price QUOTE

Image

Enmet Fixed Gas Detection System
Web Price QUOTE
Description N/A MedAir 2200 is a compact, easy to install and operate compressed airline monitor that can continuously and simultaneously monitor up to four gases in real-time using internally mounted sensors. MedAir 2200 is typically configured to monitor hospital compressed air for carbon monoxide, oxygen and dew point. Four versions available CO Monitor, CO and Oxygen Monitor, CO and Dew Point, and CO, Oxygen and Dew Point. N/A CO-GUARD is a compact, easy to install and operate compressed airline carbon monoxide monitor that meets OSHA monitoring requirements for Grade D breathing air. The instrument is specifically designed for trouble-free operation, utilizing an electrochemical carbon monoxide (CO) sensor with a life expectancy of up to three years. The CO-GUARD is supplied with a regulator assembly and five foot sample hose, and is factory pre-calibrated. N/A The ISA-60M controller with remote MRI-5175 oxygen sensor/transmitter is specifically designed to continuously monitor for oxygen deficiency in a Magnetic Resonance Imaging (MRI) facility. Maintaining the quality of breathing air in an MRI room is an important safety consideration. Cryogenic gas used to maintain the magnetic field is highly dangerous if released into an enclosed space. Inert gas can create a hazardous situation by reducing the concentration of oxygen in the breathing air to unsafe levels. The ISA-60M system ensures the safety of the technicians and patients by continuously monitoring and displaying the levels of oxygen in the room and providing audio and visual alarms when there is an unsafe, low level oxygen condition in the area being monitored. Three versions available; Single Channel, Dual Channel, and Three Channel. N/A Enmet Single Point Hazardous Gas Monitor for Ambient Air is available for Carbon Monoxide (CO), Hydrogen Sulfide (H2S), or Oxygen (O2). The AM-5175 provides a digital display of gas concentration, audio/visual alarms, relay contacts, plus analog and digital outputs. The monitor incorporates electrochemical CO, H2S or O2 cells. N/A The GSM-60 is a versatile instrument, which, in addition to having an internal sampling pump and sensors, can also accept inputs from remote gas sensor/transmitters. The system can be custom configured to monitor a variety of conditions, including VOCs, CO, CO2, oxygen, as well as many toxic and other gases. GSM-60 can also be configured on request for reactive gases, including Ozone (O3), Hydrogen Fluoride (HF), Chlorine (Cl2), etc. The instrument has a user-friendly interface for all maintenance and operation functions, and it is protected by a compact and durable enclosure for process environments.
Range (CO) N/A 0 to 50 ppm N/A 0 to 50 ppm N/A N/A N/A
Accuracy N/A 0 to 30 % N/A ± 10 % N/A N/A N/A
Alarm Level Setting N/A 10 and 20 ppm CO Alarm 1: +35 ºF Dew Point Alarm 2: +50 ºF Dew Point N/A Alarm 1: 5 ppm CO, user adjustable Alarm 2: 10 ppm CO, user adjustable Alarm 3: 20 ppm CO, user adjustable, All adjustable between 1 to 50 ppm N/A Alarm 1: 5 ppm CO, user adjustable Alarm 2: 10 ppm CO, user adjustable Alarm 3: 20 ppm CO, user adjustable, All adjustable between 1 to 50 ppm N/A N/A
Audible Alarm N/A 95 dB at 24 in N/A 105 dB at 12 in N/A 105 dB at 12 in 95 dB at 24 in N/A 105 dB at 12 in N/A 95 dB at 24 in
Inlet Size N/A 1/4 in. National Pipe Thread (NPT) Female N/A 1/4 in. National Pipe Thread (NPT) Female N/A Strain relief (2 supplied) for 0.20” to 0.35” OD Cable N/A Supplied with strain relief for 0.20 to 0.35 inch diameter power cable N/A 1/4 ID Quick Release
Operating Temperature Range N/A N/A 32 to 104 ºF N/A 32 to 104 ºF N/A 32 to 122 ºF N/A
Power Requirements N/A
Alternating Current (AC) Voltage N/A 100 to 240 V
Direct Current (DC) Voltage N/A 12 V N/A 12 V N/A 12 V N/A 24 V N/A 12 V
Power N/A 15 W N/A 15 W N/A 15 W12 W N/A 15 W N/A 15 W
Width N/A 9.3 in21.3 cm N/A 7.1 in18.2 cm N/A 10.5 in27 cm N/A 7 in18 cm N/A 9.3 in21.3 cm
Height N/A 11.9 in30.3 cm N/A 6.1 in15.5 cm N/A 8.5 in22 cm N/A 5 in13 cm N/A 11.9 in30.3 cm
Depth N/A 6.1 in15.4 cm N/A 3.5 in8.9 cm N/A 5.8 in15 cm N/A 3 in8 cm N/A 7.8 in15.4 cm
Weight N/A 8 lb N/A 2 lb N/A 10 lb N/A 2 lb N/A 9 lb
General Description N/A Display: High-contrast, backlit

Alarms: Visual: LEDs

Audible: Piezoelectric horn, 95 dB at 2 feet

Alarm Relays: 5 programmable gas relays plus fault. All relays are programmable latching or non-latching, dry SPDT, 10 amps (resistive load only) at 110 VAC

Operating Power: 100 to 240 VAC and/or 12 VDC, 15 Watts

Sensor Types: CO and O2: Electrochemical, Dew Point: Thin-Film Polymer

Sensor Life: CO: 1-3 years, with calibration, O2: 1-2 years, with calibration, Dew Point: 2 years, replacement

Response Times: Dew point: T90 = 10 seconds for -40º to 50ºF step change, CO: T90 = 30 seconds, O2: T90 = 15 seconds

Inlet Pressure: Must be regulated to 55 psi (user provided)

Flow Rate: 1/2 liter per minute (1 SCFH)

Enclosure: Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X

Dimensions: 9.3 W x 11.9 H x 6.1 D inches (21.3 W x 30.3 H x 15.4 D cm)

Weight: 8 lbs. (3.6 kg)

Approvals: UL 60601-1, IEC 60601-1 & CSA 22.2, No. 601.1

STANDARD CALIBRATIONS

Range: 0-50 ppm CO, 0-30% O2 Deficiency, 0-30% O2 Abundance, -112º to +68ºF Dew Point(-80º to +20ºC)

Alarm Points: 10 and 20 ppm CO, 19.5% O2 Deficiency, 23.5% O2 Abundance, Alarm 1: +35ºF Dew Point (+1.6º C), Alarm 2: +50ºF Dew Point (+10º C)
N/A Display: High-contrast, backlit

Resolution: 1 ppm

Alarms: Visual Gas Alarm: 3 red LEDs, Visual Power Fault: Green/Red LEDs, Audible Alarm: 105 dB at 30 cm (12 inches)

Operating Power: 110 VAC, 220 VAC and/or 24 VDC, 15W

Power Connection: Supplied with strain relief for 0.20 to 0.35 inch diameter cable

Outputs: Relays: 4 Form C, 10A SPDT contacts, 3 gas alarms and 1 fault, Analog: 4-20mA, Digital: RS-485 COM port interface using Modbus RTU

Sensor: Electrochemical

Response Time: t90 = 30 sec

Accuracy: +/- 10% of reading

Temperature Range: 32° to 104° F (0° to +40° C)

Inlet Air Line Connection: 1/4 inch NPT female

Air Line Sample Hose to Monitor: 5 foot length

Inlet Pressure: 60 to 150 psi, air supply lines, 55 psi regulated to monitor

Enclosure: Polycarbonate

Dimensions: 7.1 W x 6.1 H x 3.5 D inches (18.2 W x 15.5 H x 8.9 D cm)

Weight: 2 lbs (0.9 kg)

STANDARD CALIBRATIONS

Range: 0-50 ppm CO

Alarm Levels: Alarm 1: 5 ppm CO, user adjustable, Alarm 2: 10 ppm CO, user adjustable, Alarm 3: 20 ppm CO, user adjustable

Alarm Adjustment: All three alarms are user adjustable between 1 to 50 ppm
N/A Temperature: 32° to 104°F (0° to 40°C)
Relative Humidity: 10-99% RH, non-condensing
Pressure, Atmospheric: 20 to 36 inHg (68 to 122 kPa)
Approval: Safety Approvals: CE, Conforms to STD 61010-1, Certified to C22.2 #61010-1

ISA-60M MONITOR SPECIFICATIONS:

Standard Alarm Points: 19.5% & 17% decreasing oxygen
Display: High-contrast, backlit
Alarms: Visual: LEDs; Audible: Piezoelectric horn, 95 dB at 2 feet
Alarm Relays: 5 programmable gas relays plus fault. All relays are programmable latching or non-latching, dry SPDT, 10 amps (resistive load only) at 110 VAC.
Operating Power: 100 to 240 VAC and/or 12 VDC, 15 Watts
Connections: Strain relief (2 supplied) for 0.20” to 0.35” OD Cable
Operating Power: 100 to 240 VAC and/or 12 VDC, 15 Watts
Enclosure: Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X
Size: 10.5 H x 8.5 W x 5.8 D inches (27 x 22 x 15 cm)
Weight: 8 lbs. (3.6 kg)

MRI-5175 TRANSMITTER:

Alarms: Visual: 3 Red LEDs; Visual Power/Fault: Green/Red LED; Optional Audible Alarm: 105 dB at 12 inches (30 cm)
Outputs: 4-20 mA, RS-485 Modbus
Power: 24 VDC from ISA-60M
Connection to ISA-60M: Strain relief (1 supplied) for 24 VDC, 4-20 mA, 0.20” to 0.35” OD Cable
Enclosure: Fiberglass-reinforced polyester with non-magnetic coating and hardware
Dimensions: 5 x 5 x 4 inches (2 x 2 x 1.6 cm)
Weight: 2 lbs. (0.9 kg)
Oxygen Sensor supplied with MRI-5175: Type: Electrochemical; Range: 0 to 30.0% by Vol. O2; Resolution: 0.1% by Volume Oxygen; Typical Life: 4 to 5 years
Sensor Cable from MRI-5175 to ISA-60M: 3-wire, shielded cable, typically 18 to 20 AWG, user supplied, UL Listed type CM, PLTC or TC
N/A Display:High-contrast dot matrix LCD with backlight

Alarm Levels:Three, user adjustable

Audible Alarm:105 dB at 30 cm (12 inches), factory set to activate at Alarm 1, user adjustable

Visual Gas Alarm:3 Red LEDs

Visual Power/Fault:Green/Red LED

Temp. Range:32° to 122°F (0° to 50°C)

Outputs:Relays:4 Form C, 10A SPDT contacts, 3 gas alarms and 1 fault

Analog:4-20 mA

Digital:RS-485 Modbus

Power:100-240 VAC and/or 24 VDC, 15W. Supplied with strain relief for 0.20 to 0.35 inch diameter power cable

Enclosure:Polycarbonate

Size, Instrument Only:7 x 5 x 3 inches (18 x 13 x 8 cm)

Weight:2 lbs. (0.9 kg)
N/A Display: High-contrast, backlit

Alarms: Visual: LEDs Audible: Piezoelectric horn, 95 dB at 2 feet

Alarm Relays: 5 programmable gas relays plus fault. All relays are programmable latching or non-latching, dry SPDT, 10 amps (resistive load only) at 110 VAC.

Operating Power: 100 to 240 VAC and/or 12 VDC, 15 Watts

Sample Inlet Connection: Female quick release, supplied with male quick release for 1/4? I.D. tubing. Tubing available from ENMET on request

Flow Rate: 1 Lpm (pump/internal sensors)

Enclosure: Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X

Dimensions: 9.3 W x 11.9 H x 7.8 D inches (21.3 W x 30.3 H x 15.4 D cm)

Weight: 9 lbs.
Additional Information N/A Product Highlights
  • Continuous real-time gas monitoring of hospital compressed airlines
  • Monitors oxygen, carbon monoxide and dew point simultaneously
  • User programmable alarms and relays
  • Meets Grade D breathing and NFPA 99 requirements
  • Low flow alarm
  • Field replaceable sensors
Link

ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.
N/A Product Highlights
  • Meets OSHA 1910.134 compressed breathing air monitoring requirements
  • Continuous carbon monoxide monitor for compressed breathing air
  • Proven electrochemical sensor technology
  • Simple push button operation
  • Easy to install compact design
  • User programmable alarms and high capacity relays
  • Low maintenance field replaceable sensor
Link

ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.
N/A Product Highlights
  • Continuous monitoring of area with Long-life oxygen sensor
  • Oxygen sensor/transmitter is designed for EMC compatibility
  • User-programmable alarms and high capacity relays
  • 4-20 mA inputs and outputs
  • 100-240 VAC, 12 VDC power options
  • Fault relay and visual fault alarm
  • RS-232/485 with Modbus protocol
  • Safety Approvals: CE
  • Conforms to STD 61010-1
  • Certified to C22.2 #61010-1
ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.
N/A Product Highlights
  • User-programmable alarms and high capacity relays
  • 4-20 mA inputs
  • 100-240 VAC, 24 VDC power options
  • High-integrity polycarbonate enclosure
  • RS-485 digital communication capability
ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.
N/A Product Highlights
  • Continuously and simultaneously monitor up to four gases
  • Can be custom configured with a combination of internal and remote sensors
  • User programmable alarms and high capacity relays
  • High-integrity thermoplastic enclosure
  • 4-20 mA inputs and outputs
  • 100-240 VAC, 12 VDC power options
  • RS-232/485 with Modbus protocol
ENMET has a complete line of compressed airline monitoring and filtration systems for supplied breathing, respiratory air, process air, and hospital compressed airlines. There continuous in-line carbon monoxide CO monitors and three-stage respiratory airline filtration panels are designed to meet OSHA 1910.134 compressed breathing air monitoring requirements.